Download presentation
Presentation is loading. Please wait.
1
Towards a Scintillator-based (semi)Digital HCal
Vishnu V. Zutshi for the NICADD/NIU group
2
Calice DHCal Meeting, DESY
Introduction Can a reasonable case for a scintillator-based (semi)digital HCal (~ 9cm2 cells) be made? can E resolution be maintained ? is there enough light ? can cell processing be simplified ? can Eflow algorithms be developed ? Calice DHCal Meeting, DESY 11/3/2019
3
Calice DHCal Meeting, DESY
Energy Resolution ? Calice DHCal Meeting, DESY 11/3/2019
4
Calice DHCal Meeting, DESY
N vs. E 0.25mip threshold Calice DHCal Meeting, DESY 11/3/2019
5
Single Particle E Resolution
Non-projective geometry Calice DHCal Meeting, DESY 11/3/2019
6
Calice DHCal Meeting, DESY
Digital vs. Analog Calice DHCal Meeting, DESY 11/3/2019
7
Calice DHCal Meeting, DESY
Multiple thresholds Calice DHCal Meeting, DESY 11/3/2019
8
Calice DHCal Meeting, DESY
ZZ Events Stable MC particles Calice DHCal Meeting, DESY 11/3/2019
9
Calice DHCal Meeting, DESY
Recipe Energy Smearing Fit s as a function of incident E (slide5) and smear neutral hadrons accordingly g ~ 17%/sqrt(E), generated E for charged hadrons Jet Reconstruction pT order stable MC particles (ignoring neutrinos) start with highest pT particle and cluster in 0.7 cone repeat for remaining particles Calice DHCal Meeting, DESY 11/3/2019
10
Calice DHCal Meeting, DESY
Energy Fractions Neutral hadron fraction g fraction Calice DHCal Meeting, DESY 11/3/2019
11
Calice DHCal Meeting, DESY
Jet E Resolution rms used Calice DHCal Meeting, DESY 11/3/2019
12
Calice DHCal Meeting, DESY
Layer Stack Calice DHCal Meeting, DESY 11/3/2019
13
Calice DHCal Meeting, DESY
Enough Light ? Calice DHCal Meeting, DESY 11/3/2019
14
Calice DHCal Meeting, DESY
Cosmic Data with PMT ~11 p.e Calice DHCal Meeting, DESY 11/3/2019
15
Calice DHCal Meeting, DESY
Si-PM’s Calice DHCal Meeting, DESY 11/3/2019
16
Calice DHCal Meeting, DESY
Cosmic Data with Si-PM Calice DHCal Meeting, DESY 11/3/2019
17
Calice DHCal Meeting, DESY
Cosmic with APD Hamamatsu S8550 Calice DHCal Meeting, DESY 11/3/2019
18
Tile-Fiber Processing
Calice DHCal Meeting, DESY 11/3/2019
19
Surface Treatment/Wrapping
UNPOLISHED TOP AND POLISHED BOTTOM POLISHED TOP AND UNPOLISHED BOTTOM 0.98 1.00 1.02 Tyvek Paint VM 2002 Mylar CM590 CM500 Alum Foil 1.00 0.89 1.08 0.83 0.28 0.44 0.63 Calice DHCal Meeting, DESY 11/3/2019
20
Calice DHCal Meeting, DESY
Spray It On Titanium white acrylic Calice DHCal Meeting, DESY 11/3/2019
21
Miscellaneous Measurements
6cm2/9cm2 Straight/Sigma Square/Hex Extruded/Cast 0.95 0.94 0.7 NICADD scintillator 1mm round Kurray After/Before glue EJ500/BC600 (optical glues) Y11/BCF92 1.15 1.0 3.1 0.8 mm square Bicron Calice DHCal Meeting, DESY 11/3/2019
22
Calice DHCal Meeting, DESY
Response vs. Thickness Calice DHCal Meeting, DESY 11/3/2019
23
MEPHI-ITEP-DESY Solution
Can the cost be further reduced? Calice DHCal Meeting, DESY 11/3/2019
24
Calice DHCal Meeting, DESY
Thickness Tolerances ELJEN cast NICADD extruded Calice DHCal Meeting, DESY 11/3/2019
25
Calice DHCal Meeting, DESY
Response Dispersion Calice DHCal Meeting, DESY 11/3/2019
26
Calice DHCal Meeting, DESY
Digital Eflow? Calice DHCal Meeting, DESY 11/3/2019
27
Density-based Clustering
S+ pp0 Eflow Density weighted Cal only Calice DHCal Meeting, DESY 11/3/2019
28
Photon Reconstruction
Calice DHCal Meeting, DESY 11/3/2019
29
Calice DHCal Meeting, DESY
Jet Resolution 60% better eflow Cal only Calice DHCal Meeting, DESY 11/3/2019
30
Calice DHCal Meeting, DESY
Summary It is reasonable to consider a scintillator-based (semi)digital HCal (~ 9cm2 cells) E resolution can be maintained there is enough light cell processing can be simplified digital Eflow algorithms can be developed Calice DHCal Meeting, DESY 11/3/2019
Similar presentations
© 2025 SlidePlayer.com. Inc.