Presentation is loading. Please wait.

Presentation is loading. Please wait.

Magnetic measurements at ambient temperature on the MQXFBP1

Similar presentations


Presentation on theme: "Magnetic measurements at ambient temperature on the MQXFBP1"— Presentation transcript:

1 Magnetic measurements at ambient temperature on the MQXFBP1
Lucio Fiscarelli with the help of colleagues from MM and LMF

2 New rotating-coil scanner Measurement campaigns Results
Outline New rotating-coil scanner Measurement campaigns Results Transfer function Angle Multipoles Magnetic center – data under processing

3 Rotating-coil scanner prototype
The probe is supported by a tube Ø 100 mm On-board encoder and tilt sensor Motor unit outside Mechanical extensions for translating and rotating the probe PCB (printed circuit) coil with length 500 mm (100 mm) Measurement radius 40 mm Optical targets for referring magnetic axis to external points

4 Rotating-coil scanner final version
Ø 136 mm for the cold-bore Measurement radius 50 mm Measurement length 600 mm Based on PCB (printed circuit) coils Tilt sensor on the PCB coil Auto-alignment to gravity Retroreflectors mounted on the PCB On-board motor

5 Measurement campaigns
1) Coil pack in December 2018 Magnet was disassembled/reassembled 2) Coil pack in February 2019 3) After centering in February 2019 Issue with the prototype scanner 4) After loading in April 2019

6 Coil-pack in December 2018 *
Measurements taken by using the prototype scanner * Angular offset wrt to gravity not calibrated

7 Coil-pack in February 2019 *
Measurements taken by using the prototype scanner * Angular offset wrt to gravity not calibrated

8 After centering in February 2019
Measurements taken by using the prototype scanner

9 After loading in April 2019 Measurements taken by using the final-version scanner

10 Field quality summary average* std* integral TF 8.838 Tm-1kA-1 7 units
average* std* integral TF 8.838 Tm-1kA-1 7 units   T kA-1 * Magnet body 6.6 m Angle 0.78 mrad 0.13 0.83 b3 0.26 0.79 0.02 a3 0.50 0.99 -0.19 b4 0.41 0.48 0.38 a4 -1.23 1.65 -0.59 b5 -0.40 0.29 -0.46 a5 0.10 0.54 -0.18 b6 -5.75 0.37 -4.99 a6 0.51 -0.10 b7 -0.08 0.16 a7 0.08 b8 0.03 a8 0.24 -0.12 b9 -0.07 0.05 a9 -0.01 b10 -0.32 0.20 -0.35 a10 0.01 b11 -0.05 0.04 a11 -0.04 b12 -0.02 a12 0.00 b13 a13 b14 -0.74 a14 b15 a15

11 Full set of measurements data
Conclusions Full set of measurements data Coil pack, centering, loading Field quality is within specifications Multipoles < 1 unit (apart from b6 that will be cured) Angle < 1 mrad Random positioning of blocks ~25 microns Validation of the new scanner system