Download presentation
Presentation is loading. Please wait.
1
Variable Gauge R&R Part Selection
Think about your specification ranges when selecting parts Parts should represent the normally expected range for a part This implies you have data Specification Width (Pass/Fail Criteria) Part Selection Range Variable Gage RR
2
Variable Gauge R&R Part Selection – The Wrong Way
Specification Width (Pass/Fail Criteria) Part Selection Range Failed Gage R&R trying to distinguish this WHEN YOU SHOULD HAVE BEEN LOOKING AT THIS The gage may be fully capable of distinguishing part-to-part within the specification Beware of “more decimals is better” Variable Gage RR
3
Variable Gauge R&R Part Selection – The Wrong Way
Part Selection Range (Multiple sizes in product line ) Individual Part size Range When you should have been looking at this Passed Gage R&R Looking At This You know the gage is capable distinguishing parts from one product size to another You do not know if it can separate good from bad within a specific size Variable Gage RR