Download presentation
Presentation is loading. Please wait.
1
Panasonic System Networks PBX SE team
KX-NS1000 Step by Step Guide E1 Adapter / PRI Adapter KX-NS8188 / KX-NS8290 September 11, 2013 Panasonic System Networks PBX SE team 1 1
2
1. Introduction When customers want to use IP-Phone mainly for extension and they want to use E1 or more than 2 PRI as trunk, KX-NS1000 version 2 with trunk adapter is recommended. Activation key for IP trunk is not required to connect E1 / PRI adapter. Trunk adapter cannot be connected with other PBX using SIP. Panasonic KX-NS8290 PRI30 Trunk Adaptor SIP Extension PRI30 Model Specifications KX-NS8188X E1 adapter on SIP trunk KX-NS8290CE PRI30 adapter on SIP trunk KX-NS8290X PRI23 adapter on SIP trunk SIP Trunk (30-ch) KX-NS1000 IP Trunk AK PRI Card IP Network KX-NCS0290 215 mm (W) 44 mm (H) 200 mm (D) 500g KX-NT KX-UT Other SIP Phone SIP Softphone 2
3
2. Stacking Card Reference When customer has Panasonic PBX now, they can add IP capacity and built-in solution using KX-NS1000 version 2 with stacking card KX-NS0130 with keeping current PBX. KX-TDA0131/0132 is installed instead of MPR card. This configuration is useful for new customer also to increase SLT and so on. KX-NS0130 Stacking card for NS100 KX-NS0131 Stacking card for NCP KX-NS0132 Stacking card for TDA/TDE Before adding KX-NS1000 After adding KX-NS1000 Analog CO Analog CO Direct Connection like TDE600 to TDE620 KX-TDE KX-TDE KX-NS1000 CO Card CO Card MPR Card SC Card SC Card EXT Card EXT Card KX-NCS0130 100 % Feature Transparency like TDE600 and TDE620 IP Network SLT KX-DT w/ DSS Console KX-NT KX-UT Other SIP Phone SIP Softphone SLT KX-DT w/ DSS Console 3
4
3. Table of Contents Chapter Explanation 1 Overview 2 Specifications 3
Concept of programming for Public mode 4 Step by step programming for the trunk adapter 5 Step by step programming for KX-NS1000 6 Programming hint for Private mode (QSIG) 7 Demonstration guide 4
5
Chapter 1 Overview
6
11. Capacity Maximum 256 ch is available for E1 / PRI by adapter and IP trunk. Line NS1000 x 1 NS1000 x 2 NS1000 x 3 NS1000 x 4 or more Trunk 256 256 x 2 600 Legacy IP incl E1/PRI adapter SIP H.323 48 48 x 2 = 96 Also useful to provide PRI/E1 with 2-ch Analog CO or 4 BRI. PRI30 E1 PRI30 E1 SIP Provider Trunk Adaptor Trunk Adaptor PRI30 E1 SIP Trunk (xx-ch) SIP Trunk (30-ch) SIP Trunk (30-ch) PRI30 256ch Trunk Adaptor Analog CO SIP Trunk (30-ch) PRI Card CO Card Max. 256ch can be registered to SIP provider or the adapter.
7
12. PRI Adapter - Fractional Service
Fractional service is also available. <Stand alone> 20ch E1/PRI Trunk Adaptor 20ch KX-NS1000 <One-look network> 20ch E1/PRI 60ch E1/PRI 10ch E1/PRI Trunk Adaptor Trunk Adaptor Trunk Adaptor Trunk Adaptor Total 256ch 20ch 30ch 30ch 10ch 1st KX-NS1000 in Fukuoka 2nd KX-NS1000 in Tokyo 16th KX-NS1000 in Niseko
8
13. PRI Adapter - QSIG PRI adapter supports ISDN QSIG also to connect with other PBX. Activation key for IP trunk is not required for PRI adapter. Trunk adapter cannot be connected with other PBX using H.323. KX-NS1000 PRI H.323 Ext 2xx IP Trunk AK Trunk Adaptor ISDN QSIG Ext 1xx KX-TDA/TDE/NCP or PBX by other maker IP Network (VPN) Ext 3xx DN2IP table (Dial to IP) Dial 2xx to Dial 3xx to Dial 4xx to Ext 4xx
9
14. PRI QSIG – Capacity & Specification
H.323 is used for this configuration instead of SIP. Line NS1000 x 1 NS1000 x 2 NS1000 x 3 NS1000 x 4 or more IP incl E1/PRI adapter 256 SIP + PRI Adapter for Public H PRI Adapter for QSIG 48 48 x 2 = 96 Features NS8290 TDA0290 (Reference) QSIG service CLIP/CLIR Yes CNIP/CNIR Call Forwarding (CF) Call Transfer (CT) Completion of Calls to Busy Subscriber (CCBS) Network Direct Station Selection (NDSS) Centralized Voice Mail Network ICD Group KX-NS8290 Trunk Adaptor KX-NS0290 PRI Card KX-NS1000
10
Chapter 2 Specifications
11
21. Hardware Appearance Hardware Appearance is as follows. No.
Front No. Description 1 System LED 2 E1 / PRI line LED 3 DC Jack 4 LAN Port 5 LAN LED (Link) 6 LAN LED (Transmission Speed) 7 E1 / PRI line port 8 Initialize button (Not slide switch) Back Wall Mountain Unpack the box and check the items below: Main Unit x 1 Screw x 2 Washer x 2
12
22. PoE (Power over Ethernet)
KX-NS8188 / KX-NS8290 supports PoE. If PoE is not supported by network, AC adapter is required KX-A420 for Brazil KX-A239 for others *) These are same model of AC adapter for KX-UT phone.
13
23. KX-NS8188 E1 Adapter KX-NS8188 E1 adapter supports following features. Features NS8188 TDA0188 (Reference) Signaling DR2 Yes E&M-C No E&M-P Dial Type MFC-R2 DTMF Pulse Caller Number Notification (ANI) Charge / Meter Pulse Deny collect call for Brazil Outgoing call auto disconnect E1 KX-NS8188 Trunk Adaptor KX-TDA0188 KX-TDE KX-NS1000
14
24. KX-NS8290 PRI Adapter KX-NS8290 PRI adapter supports following features. Features NS8290 NS0290 (Reference) Mode CO (Public) Yes Extension No QSIG-master/slave (Private) ISDN Carrier Service (Public) CLIP / CLIR COLP / COLR CNIP /CNIR CONP / CONR Advice of charge Call Forwarding Call Hold Call Transfer (incl. ISDN Centrex) Tree-party conference Malicious call identification Generic keypad protocol CCBS ISDN - Virtual Private Network E-911 (for PRI23) “No” because these services by ISDN provider are not popular and PBX can support same feature basically. Conf by PBX Conf by ISDN ISDN KX-NS8290 Trunk Adaptor KX-NS0290 PRI Card KX-NS1000
15
25. Solution with “Back-up Master”
Back-up is available automatically for SIP trunk incl E1 / PRI adapter, KX-NT/UT IP-phone. PRI/E1 or SIP Provider Back-up master PBX works as slave PBX usually. But it works as master PBX after master PBX stops working. Trunk Adaptor KX-NS1000 (2nd) Back-up Master SIP Trunk One-Look AK One-Look AK KX-NS1000 (1st) Master KX-NT KX-UT KX-NT KX-UT PRI/E1 or SIP Provider Trunk Adaptor After master PBX stops working, KX-NS1000 Back-up Master SIP Trunk One-Look AK One-Look AK KX-NS1000 Master KX-NT KX-UT KX-NT KX-UT
16
Chapter 3 Concept of Programming for Public Connection
17
31. Concept of Programming - Adapter
The trunk adapter is PBX with E1 / PRI trunk and SIP extension. SIP trunk of KX-NS1000 is registered to SIP extension of the adapter. <Programming for the trunk adapter> Software of the adapter is basically same as KX-NS1000. Features except E1 / PRI and SIP extension are removed. Therefore programming method is very similar to KX-NS1000. E1/ ISDN - PRI configuration is same as programming for KX-NS1000 PRI card (KX-NS0290). E1 configuration is same as KX-TDE E1 card (KX-TDA0188) SIP extension configuration is same as KX-NS But SIP extension is programmed by default to 430 for E1 / PRI to 423 for PRI23 PRI E1 / PRI Trunk Adaptor SIP Extension 30ch or 23ch ID SIP Trunk KX-TDA0188 PRI Card KX-TDE KX-NS1000 KX-NS0290 17
18
32. Concept of Programming – NS1000
<Programming for KX-NS1000> The trunk adapter is basically SIP provider for KX-NS1000. Following has to be programmed. - IP address of the adapter as SIP server destination - SIP registration User ID (Password is not required.) - Connection Attribute : SIP Provider / Trunk Adapter E1/ ISDN E1 / PRI Trunk Adaptor SIP Extension 30ch or 23ch ID SIP Trunk KX-NS1000 18
19
33. Concept of Programming - Call
<Programming for KX-NS CONT> Programming of the trunk adapter is not required for DDI / DIL incoming call from E1/PRI to SIP extension. It works like DIL 1:1 without programming and DDI number and caller ID are informed from the trunk adapter to KX-NS Programming of KX-NS1000 is required for DDI / DIL. Outgoing call is also programmed for KX-NS1000 instead of the trunk adapter. Therefore administrator has to access only KX-NS1000 to change extension number, DDI and so on after dealer installed. E1 / ISDN E1 / PRI CH CH CH30 Trunk Adapter DDI Caller ID SIP Extension SIP Trunk KX-NS1000 19
20
Chapter 4 Step by Step Programming for Trunk Adapter
Trunk Adaptor KX-NS1000
21
41. Initialize Operation and “SYSTEM” LED display is as follows. 1. Power On (Connect AC adapter or connect LAN with PoE) (a) Amber On (5 sec) (b) Amber rapid flash (5 sec) 2. During (b), keep pressing Initialize button for 1s. (c) Off (2 sec) (d) Amber On (30 sec) (e) Amber slow flash (120 sec) (f) Green slow flash - Display of (b) finishes before 5 sec after operation of (2). - Display of (f) means success of initialization and awaiting “Easy set-up” of web maintenance console. Trunk Adaptor KX-NS1000 System LED Initialize Button 21
22
42. LED Indication LED indication is as follows. KX-NS1000 22
Trunk Adaptor KX-NS1000 22
23
43. PC Connection - 1 (1) Set IP address for example to your PC like first connection of KX-TDE or KX-NCP Trunk adapter does not have maintenance port with DHCP server Sub-net mask should be (2) Connect by Firefox Default IP address of trunk adapter is Trunk Adaptor KX-NS1000 KX-NS1000 DHCP Server by default Trunk Adapter For demo, NS1000 with DHCP server function is useful to assign IP address of PC automatically. for example by default 23
24
43. PC Connection - 2 (1) In 10 seconds from step in previous page, log-in menu is displayed. (2) Input “INSTALLER” as user and “1234” as password. Trunk Adaptor KX-NS1000 24
25
44. Easy setup - Language selection
(1) Select language. Trunk Adaptor KX-NS1000 25
26
44. Easy setup - 1 (1) Select Suffix of KX-NS1000 and area.
Trunk Adaptor KX-NS1000 No need to change If Suffix is changed, system restarts again after click [OK]. Wait 3 min and connect PC again. (a) Amber slow flash (30 sec) (b) Amber On (10 sec) (c) Amber rapid flash (5 sec) (d) Amber On (30 sec) (e) Amber slow flash (120 sec) (f) Green slow flash 26
27
44. Easy setup - 2 No need to change. - Adapter name is only for reference. - Time is used only for error log. Trunk Adaptor KX-NS1000 27
28
44. Easy setup - 3 (1) Input IP address of trunk adapter in actual customer’s network. Get the IP address from IT manager. *) For demo, default is OK. Trunk Adaptor KX-NS1000 28
29
44. Easy setup - 4 No need to change. - Time is used only for error log. Trunk Adaptor KX-NS1000 29
30
44. Easy setup - 5 (1) Input password as you hope, click [Finish]. (2) Wait for 30 seconds. Trunk Adaptor KX-NS1000 If LAN setting is changed, system restarts again after click [OK]. Wait 3 min and connect PC again. (a) Amber slow flash (30 sec) (b) Amber On (10 sec) (c) Amber rapid flash (5 sec) (d) Amber On (30 sec) (e) Amber slow flash (120 sec) (f) Green slow flash 30
31
45. Maintenance Console - Top menu
If LAN setting is changed, (1) Remove the trunk adapter from LAN (2) Connect it to actual customer’s network. (3) Connect PC to IP address of trunk adapter using Firefox. (4) After log-in, following top menu is displayed. If LAN setting is not changed, following Top menu is displayed. Trunk Adaptor KX-NS1000 31
32
45. Maintenance Console - 1 Software version can be confirmed as follows. Trunk Adaptor KX-NS1000 32
33
45. Maintenance Console - 2 Parameter for PRI can be modified as follows. (Same as “PRI + 2 SLT” card) Trunk Adaptor KX-NS1000 33
34
45. Maintenance Console - 3 IP address of adapter can be changed. (No need to change usually.) Trunk Adaptor KX-NS1000 34
35
45. Maintenance Console - 4 Software can be updated by one step. (Not same as KX-NS1000) - Wait 15 minutes after clicking [Execute]. (Same as KX-NS1000.) Trunk Adaptor KX-NS1000 35
36
45. Maintenance Console - 5 E1/ PRI Card diagnosis is supported.
Trunk Adaptor KX-NS1000 Out of service can be assigned. This is required for software update also. 36
37
Chapter 5 Step by Step Programming for KX-NS1000
38
51. KX-NS Out of Service Install virtual SIP trunk card. Out of service is required for port or card before programming in following pages. Trunk Adaptor Trunk Adaptor KX-NS1000 38
39
52. KX-NS1000 - Connection Attribute
Change connection attribute from “SIP provider” to “Trunk Adapter” for each channels or click [Trunk Adapter] button to change max. 30 ch at the same time. Trunk Adaptor Trunk Adaptor Use this No need to program each ch. KX-NS1000 39
40
53. KX-NS1000 - Trunk Adapter button - 1
Input IP address of trunk adapter and click [Next]. - Trunk adapter name is for reference. Trunk Adaptor Trunk Adaptor KX-NS1000 Web maintenance console for the trunk adapter is opened. For reference Max. 16 Adapter *) If program manually not using “trunk adapter”, more than 16 adapter can be programmed. 40
41
54. KX-NS1000 - Trunk Adapter button - 2
Select range to connect the trunk adapter instead of SIP provider. Select IP address and click [Finish]. If fractional service is used, set “20” for example. Otherwise NS1000 tries making call using 21ch to 30ch of PRI. SIP Provider Trunk Adaptor Trunk Adaptor KX-NS1000 41
42
55. KX-NS1000 - Registration to SIP Server
Connection attribute were programmed by previous step. Parameters for registration to SIP server (E1/PRI adapter) were also programmed. Trunk Adaptor Trunk Adaptor KX-NS1000 42
43
56. KX-NS CLIP “PBX CLIP” has to be selected as follows to send CLIP on extension for outgoing call. Trunk Adaptor Trunk Adaptor KX-NS1000 43
44
57. KX-NS In Service Set In Service. - Other programming such as ARS, TRS is basically same as PRI for KX-TDE/NCP. - However it is required to program as next 2 pages additionally because I/F with trunk adapter is SIP. E1 / ISDN Trunk Adaptor KX-NS1000 When E1/PRI line of trunk adapter is fault, trunk adapter stops communication with KX-NS1000. Therefore the SIP trunk ch of KX-NS1000 becomes fault. This specification is useful not to use the SIP ch automatically for ARS and so on. 44
45
58. KX-NS Dialing Plan Dialing plan has to be programmed for outgoing call because I/F with trunk adapter is SIP en-block dial. Otherwise extension caller has to wait for 10 seconds to hear ring back tone after dial to E1/PRI trunk adapter. Trunk Adaptor Trunk Adaptor KX-NS1000 45
46
59. KX-NS1000 - DDI Modification
DDI first 3 digits has to be removed because I/F with trunk adapter is SIP. ID such as “401” + real DDI number is informed as DDI number from E1/PRI adapter to KX-NS1000. E1 / ISDN Trunk Adaptor DDI 5101 DDI DDI KX-NS1000 DDI 5101 Program DDI table. 46
47
60. KX-NS1000 - DDI Destination
DDI destination programmed is also required. (Same as PRI+SLT2 card in KX-NS1000 or PRI card through stacking card ) 47
48
Chapter 6 Programming Hint for Private Mode (QSIG)
49
61. Easy Setup for Adapter “Private” has to be selected by easy setup mode. KX-NS1000 H.323 Ext 2xx Trunk Adaptor ISDN QSIG Ext 1xx
50
62. PRI QSIG mode for Adapter
QSIG (Slave) is assigned automatically after easy setup. KX-NS1000 H.323 Ext 2xx Trunk Adaptor ISDN QSIG Ext 1xx
51
63. H.323 programming for Adapter
H.323 destination programming of adapter is also required. Common IP address is assigned for any dial. (Not each dial) KX-NS1000 H.323 Ext 2xx Trunk Adaptor ISDN QSIG Ext 1xx IP address of Back-up master PBX
52
64. H.323 programming for KX-NS1000
H.323 destination programming of KX-NS1000 is required for adapter as well as other PBXs. Sole difference is that activation key for IP trunk is not required. KX-NS1000 H.323 Ext 2xx Trunk Adaptor ISDN QSIG Ext 1xx IP Network Ext 3xx DN2IP table (Dial to IP) Dial 2xx to Dial 3xx to Dial 4xx to Ext 4xx
53
Chapter 7 Demonstration Guide
54
KX-TDE with 2 PRI Extension as ISDN provider
71. Configuration Example KX-TDE with 2 PRI Extension as ISDN provider DLC PRI PRI Ext Ext 31X Ext 32X (for test) PRI Adaptor SIP Trunk (30-ch) KX-NS1000 KX-NCP with PRI PRI Ext 101 CLIP 01311 Ext 102 CLIP 01312 Ext 201 CLIP 01321 54
55
KX-TDE with 2 PRI Extension as ISDN provider
72. Outgoing Call KX-TDE with 2 PRI Extension as ISDN provider DLC PRI PRI Dialing plan 3XX Ext Ext 31X Ext 32X (for test) DDI 321 Dial 321 (Remove 01 by ARS) Dial 321 PRI Adaptor SIP Trunk (30-ch) KX-NS1000 KX-NCP with PRI PRI DDI Program Dial 0/ 01311 Ext 101 CLIP 01311 Ext 102 CLIP 01312 Ext 201 CLIP 01321 55
56
KX-TDE with 2 PRI Extension as ISDN provider
73. Incoming Call KX-TDE with 2 PRI Extension as ISDN provider DLC PRI PRI Ext Ext 31X Ext 32X (for test) Dial 312 (Remove 01 by ARS) DDI 312 PRI Adaptor DDI SIP Trunk (30-ch) KX-NS1000 KX-NCP with PRI DDI Program PRI 01321 Dial 0/ Ext 101 CLIP 01311 Ext 102 CLIP 01312 Ext 201 CLIP 01321 56
57
74. PRI Extension DLC PRI PRI Standard LAN cable can be used by this switch for PRI Extension. Ext Ext 31X Ext 32X (for test) PRI Adaptor PRI 57
58
75. KX-NS1000 – SIP Register Resending
“Register Resending Interval” has to be 10 seconds. If default value 300 seconds is used, it takes for 0 to 300 seconds to reconnect KX-NS1000 and trunk adapter, when trunk adapter returns IN Service from Out of Service or LAN is reconnected. Trunk Adaptor Trunk Adaptor KX-NS1000 58
59
Thank you !
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.