Download presentation
Presentation is loading. Please wait.
Published byἙλένη Καρράς Modified over 5 years ago
1
SSRAC 2019 Robert Cloutier September 10 – 12, 2019
NSRP Joint SP&C and EH&S Panel Meeting Quonset Point, RI
2
VASCIC – Newport News Shipbuilding
SSRAC 2019 (FY21) Standard Specification For Ship Repair and Alteration Committee June 2019 VASCIC – Newport News Shipbuilding Virginia Advanced Shipbuilding and Carrier Integration Center
3
SSRAC - Subcommittees Unless designated
Environmental / Safety / Health Hull / Preservation Machinery / QA Piping / Boiler Electrical / Electronics General (non-trade specific) 4-E / Phraseology
4
SSRAC – Hull / Preservation
Unless designated as a Government Representative, Contractors are non-voting participants of the Subcommittee also known as “Participant Witnesses”. Our Industry Partners’ serve as “information providers” to the Subcommittees, and they do not participate in the deliberations by the Government members of the Subcommittees to reach consensus on what to recommend to the Steering Committee, nor do they vote on any matter before the Subcommittee. NSRP – SP&C Panel Representatives Robert Cloutier Steve Cogswell
5
NSI – NAVSEA Standard Items
Quality Management System Deck Covering Requirements Cleaning and Painting Requirements TSN – Thermal Sprayed Non-skid Proposals for change Adopted Adopted as modified Not adopted Other
6
Hull / Preservation Subcommittee
Reviewed a total of 83 total change proposals 16 Adopted 32 Adopted as Modified 32 Not Adopted 3 Other
7
Key Changes 009-04 Check-point notification reduced from 4 to 2 hours 009-32 Eliminate “Chloride” and require Conductivity Measurements Mil-PRF-23236, Type VII, Class X/18: Single Coat UHS epoxy, limited to 3% touch-up with alternate coatings Non-skid: segregated rolled vs spray applied Standardized the number of reading for testing; per 5,000 sq ft Anchor tooth profile for non-skid was 10 vs 13 Conductivity reading was 9 vs 13 Dust test was 10vs 13 Complete review for Thermal Sprayed Non-skid FY20 NRL testing showed that chloride measurements do not pick up non-chloride water-soluble salts while conductivity-based total salts detect the chlorides in addition to the non-chloride water soluble salts. This may allow the application of paint over a surface contaminated with other salt types, such as nitrates and phosphates, which are detrimental to coating systems Non-skid specifically segregated to stated either spray or roll applied
8
Discussed, but not adopted
009-32 Non-skid applications Requirement to apply Type V spray-able non-skid commercial equipment meeting A-A-28852 Requirements to mix non-skid with a mixer qualified to A-A-59984 Abrasive blasting on aluminum (non-ferrous metals) Waiting for final approval of SSPC-17 “Thorough Abrasive Blasting” Non-skid sprayer Developed to mix MIL-SPEC nonskid deck coatings, ICM2000 has the power to completely mix thick coatings containing abrasive materials.
9
Opening Remarks Dale Hirschman: Technical Director, CNRMC Code 200
287 US Navy ships to maintain Limited Dry-docks available San Diego has the least available dry-dock locations Streamline dry-docking; Reduce schedule and time DDG 51 class: Optimum ~110 days CNRMC – Commander, Navy Regional Maintenance Center
10
Navy/Industry NSI Review
On-going Projects: 50% Checkpoint Reduction Pilot Initiative An aggressive “stretch” approach with an objective of executing pilot availabilities with significantly reduced Checkpoints content 2 East Coat – 2 West Coast USS ARLEIGH BURKE (DDG 51) – Norfolk, VA USS BULKELEY (DDG 84) – Norfolk, VA USS SHOUP (DDG 86) – Everett, WA USS ESSEX (LHD 2) – San Diego, CA
11
Underwater Hull Paint Pilot
Background: Industry proposed that the underwater (U/W) hulls of Navy ships could be painted in one quarter of the time if accomplished the way MSC U/W hull preservation is accomplished CNRMC observed an MSC ship undergoing U/W hull preservation and acquired the MSC specification. Required checkpoints were almost identical. The only technical difference was a slightly higher threshold for chlorides (conductivity). Obtained TWH concurrence to pilot the MSC model Way forward: Developing an NSI that describes the application process for U/W hull preservation (95% complete). Developing contract that will be used in the solicitation package for: Obtaining a Third Party Paint OEM to act as government representative. Purchase paint as GFM. Provide a two year warranty for the paint. CNRMC – Commander, Navy Regional Maintenance Center MSC – Military Sealift Command OEM – Original Equipment Manufacturer NSI – NAVSEA Standard Item GFM – Government Furnished Material
12
Drydock – Propulsion Work
Master Specification Catalog (MSC) Checkpoint Reduction Initiative A systematic and sustainable approach for reviewing Work Templates in order to reduce the number of Checkpoints (by system/equipment). Initial systems for review include: SWILN 245 Controllable Pitch Propellers (CPP) 312 (G) Checkpoints in FY19 SWILN 243 Propulsion Shafting (G) Checkpoints in FY19 SWILN 244 Propulsion Shaft Bearings 146 (G) Checkpoints in FY19 ~685 government check-points
13
Clarification of Change to Technical Representative; provide “The NSI Technical Representative will only be contracted by the prime contractor and the same company cannot provide both the Technical Representative and perform the actual production work.” CNRMC Letter: Clarification for Use of NAVSEA Standard Item , During Surface Ship Maintenance Availabilities Clarifies OEM role augmenting the Government oversite vice production support. 4E Guidance: Generally technical support should be provided by the supervisor. The Technical Representative should only be requested when: Technical documentation is not available to the supervisor. The supervisor does not have sufficient personnel to support oversight of maintenance being performed. Special tools or equipment are required. The supervisor does not have personnel with the knowledge or expertise to support the maintenance being performed. Planners must identify what services the technical representative is to provide. NSI will be invoked as a pre-priced option when the need for a Technical Representative for a Work Item in an availability is unknown. When invoked in a work specification, the Technical Representative providing the technical support may witness/conduct (G) checkpoints as authorized by the supervisor.
Similar presentations