PCMB Address Assignments per Station/Rack/Crate
11/20/2019 PCMB Address Assignments per Station/Rack/Crate Example Station Example Rack 1 2 3 4 5 6 Trigger sector #3 Crate top #2 2 crate “top” X Y Z 1 crate “bottom” Rack #4 11/20/2019 A.Golyash, CERN
2
PCMB Address in Decimal and HEX notation
11/20/2019 PCMB Address in Decimal and HEX notation Station +1 1 01 2 02 3 03 4 04 5 05 6 06 Station +1 7 07 8 08 9 09 10 0A 11 0B 12 0C Station +2 13 0D 14 0E 15 0F 16 10 17 11 18 12 Station +3 19 13 20 14 21 15 22 16 23 17 24 18 Station +4 25 19 26 1A 27 1B 28 1C 29 1D 30 1E Station -1 31 1F 32 20 33 21 34 22 35 23 36 24 Station -1 37 25 38 26 39 27 40 28 41 29 42 2A Station -2 43 2B 44 2C 45 2D 46 2E 47 2F 48 30 Station -3 49 31 50 32 51 33 52 34 53 35 54 36 Station -4 55 37 56 38 57 39 58 3A 59 3B 60 3C ELMB Address Configuration ON 11/20/2019 A.Golyash, CERN
3
PCMB Address Assignments for Station +1/+2/+3/+4
11/20/2019 PCMB Address Assignments for Station +1/+2/+3/+4 2 3 Station +1 1 4 6 5 10 11 9 8 12 7 YE+1 18 24 21 15 19 13 Station +2/+3 1 3 2 4 6 5 20 14 23 17 16 22 YE+2 25 Station +4 1 3 2 4 6 5 26 29 28 30 27 YE+3 X Y Z The PCMB addresses must be set according to the table on page 1 (see labels on the signal cables from/to peripheral crate). 11/20/2019 A.Golyash, CERN
4
PCMB Address Assignments for Station -1/-2/-3/-4
11/20/2019 PCMB Address Assignments for Station -1/-2/-3/-4 32 33 Station -1 1 3 2 4 6 5 35 34 40 41 39 38 42 31 37 36 YE-1 54 48 45 51 49 43 Station -2/-3 1 3 2 4 6 5 50 44 53 47 46 52 YE-2 55 Station -4 1 3 2 4 6 5 56 59 58 60 57 YE-3 X Y Z The PCMB addresses must be set according to the table on page 1 (see labels on the signal cables from/to peripheral crate). 11/20/2019 A.Golyash, CERN
5
VME Peripheral Crate - to - Station Correspondence
11/20/2019 VME Peripheral Crate - to - Station Correspondence 1/2 1/3 Station +1/-1 1 3 2 4 6 5 1/5 1/4 1/10 1/11 1/9 1/8 1/12 1/1 1/7 1/6 YE+1 & YE-1 3/6 2/6 2/3 3/3 3/1 2/1 Station -2/-3 1 3 2 4 6 5 3/2 2/2 3/5 2/5 2/4 3/4 YE -2 X Y Z 4/1 Station +4/-4 1 3 2 4 6 5 4/2 4/5 4/4 4/6 4/3 YE+3 & YE-3 2/6 3/6 3/3 2/3 3/1 2/1 Station +2/+3 1 3 2 4 6 5 3/2 2/2 3/5 2/5 2/4 3/4 YE +2 Notation inside crates : Station / Trigger Sector 11/20/2019 A.Golyash, CERN
6
References [1] J.Hauser, etc. [2] H.Boterenbrood,
11/20/2019 References [1] J.Hauser, etc. CMS-IN-2007/024, CSC Strip, Wire, Chamber, and Electronics Conventions, April, 2007 (previously CMS-IN-2000/004v2.5) [2] H.Boterenbrood, CANopen ApplicationSoftware for the ELMB, Version 2.2, NIKHEF, Amsterdam, 13 January 2005, [3] B.Bylsma, Peripheral Crate – to – Chamber Correspondence and Slot Assignments, 4 March 2003, 11/20/2019 A.Golyash, CERN