Presentation is loading. Please wait.

Presentation is loading. Please wait.

Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2

Similar presentations


Presentation on theme: "Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2"— Presentation transcript:

1 Measurement of charge collection in p-type microstrip sensors with SCT128 chip
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2 1Jožef Stefan Institute, Ljubljana, Slovenia 2 Faculty of Mathematics and Physics, University of Ljubljana, Slovenia I. Mandić, 3rd Workshop on Advanced Si Detectors , Barcelona, June 2008

2 Setup for measurements with SCT128 chip was built in Ljubljana:
SCTA128VG chip drawings of test pcb from CERN (thanks to Jan Kaplon) VME module SEQSI (for clock, commands...) Tektronix digital scope for data acquisition Cambridge LabView software for chip control (thanks to Dave Robinson) data acquisition software (thanks to G. Kramberger ) pitch adapters from Freiburg (thanks to Uli Parzefal) coincidence circuit made by Erik Margan 90Sr source, photomultiplier, scintillator, power supplies.... I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

3 Test PCB Detector (1.2x1.2 cm2) SCTA128VG Fanin Al detector support
and heat spreader PT100 I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

4 Scintillator is under the
Aluminium support structure dimensions: ~ 25 cm x 20 cm x 6 cm 90Sr source is inserted into the upper collimator Test board holder Scintillator is under the lower collimator Photo Multiplier Light guide I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

5 Setup in the fridge, temperature about - 20° C
90Sr source holder I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

6 charge sensitive front-end amplifier with about 20 ns peaking time
SCTA128VG chip 128 channels charge sensitive front-end amplifier with about 20 ns peaking time sampled every 25 ns (40 MHz sampling clock) Gain = 26.5 mV/fC = 4.2 µV/el measured with calibration signals from on-chip capacitors (~10 % accuracy) noise with detector connected ~ 800 el Strips bonded I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

7 p-type, FZ material, 300 µm thick strip detectors strip pitch 80 µm
n-in-p capacitively coupled polysilicon biased, p-sprayed designed by Liverpool, produced by Micron Semiconductor, sent to us by Gianluigi Casse I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

8 1 MeV equivalent fluences (same fluence steps as for Liverpool):
Irradiations detectors were irradiated with neutrons in the TRIGA reactor in Ljubljana 1 MeV equivalent fluences (same fluence steps as for Liverpool): 5·1014 n/cm2 1.6·1015 n/cm2 3·1015 n/cm2 after irradiation detectors were annealed for 80 minutes at 60° C I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

9 fitted with convolution of Landau and Gauss functions
Measurements trigger: signals caused by electrons from 90Sr source in scintillator in coincidence with 40 MHz clock edge spectrum of signals from strips (pedestals and common mode variations subtracted) fitted with convolution of Landau and Gauss functions  “Most Probable Value” of the Landau function (parameter p1 in the plot below) returned by the fit is the measure of collected charge Bias = 350 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

10 measurements taken at -20° C statistical error of points ~ 5%
Signal vs. Bias Voltage measurements taken at -20° C statistical error of points ~ 5% highest voltage limited by breakdown repeats of measurements are shown at two highest fluences (reproducibility test) I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

11 Comparison of spectra in which MP ~ 20 kel measured after different fluences
(normalized to the equal number of clusters in histogram) signals at high voltage after irradiation as high as before irradiation I < 1 µA I ~ 20 µA I ~ 400 µA I ~ 250 µA (better cooling) I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

12 good agreement with Liverpool results
Signal vs. Fluence good agreement with Liverpool results with present cabling in ATLAS the highest voltage is 500 V it seems that higher bias voltage would help I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

13 after very high fluence detectos can be operated under forward bias
Ф = 1.6·1015 n/cm2, T ~ -40° C (a cup of liquid N2 put into the fridge) Bias = +300 V, I = 200 µA, MPV = 10 kel Reverse bias ~ -600 V needed for same MPV, but much lower current (less than 10 µA at this T) Ф = 3·1015 n/cm2, T ~ -24° C, Bias = +400 V, I = 600 µA, MPV = 6.5 kel Reverse bias ~ -600 V needed for same MPV, but much lower current (35 µA at this T) I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

14 were measured with SCT128 chip
Conclusions signals caused by fast electrons from 90Sr source in p-type microstrip detectors were measured with SCT128 chip measurements were made up to very high bias voltages (max.1700 V) CCE as high as before irradiation measured at sufficiently high voltage in detectors irradiated up to Ф = 3·1015 n/cm2 good agreement with measurements from Liverpool I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

15 Modul 0, Фeq = 0 n/cm2, exposed to few Mrads of gammas
Backup plots Modul 0, Фeq = 0 n/cm2, exposed to few Mrads of gammas I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

16 Number of strips per cluster
Ф = 0, Bias = 350 V Ф = 5e14, Bias = 800 V Ф = 1.6e15, Bias = 1100 V Ф = 3e15, Bias = 1600 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

17 Number of strips per cluster forward bias
Ф = 3e15, Bias = +400 V Ф = 1.6e15, Bias = +300 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

18 signal mean vs. trigger delay, before irradiation Bias = 200 V
Pulse shape signal mean vs. trigger delay, before irradiation Bias = 200 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

19 measurements for which MPV ~ 20000 el
Signal to noise measurements for which MPV ~ el I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008


Download ppt "Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2"

Similar presentations


Ads by Google