DEMA TITAN WAREWASH T-812 &T-813 Instructional Presentation
2
The Titan responds to detergent and rinse triggers in the range of
The Titan ware wash system controls all chemical delivery functions for dish machines and similar warewash applications. The system has an advanced power supply that will accept 100V–250V 50/60Hz. The Titan responds to detergent and rinse triggers in the range of 20V–500V 50/60Hz. The Titan has been designed for simple installation, set up, and operation. The Titan has an Auto Switchover feature that allows automatic switching from Concentration to Probeless in the case of a probe fault, (and back again if the fault clears). This feature allows continued operation or the dish machine while cutting down on unnecessary service calls. Conditions that can activate this feature are the following: Open probe – a probe wire is disconnected or there is lime buildup on the tips. Closed probe – a piece of flatware may be lying across the probe tips. Detergent not feeding properly – too much or too little detergent.
3
Chapter Selection Click on the chapter you wish to view
1. Installation 2. Initial Programming 3. System Access 4. Diagnostic Mode 5. Accessories 6. Parts Breakdown Click on the chapter you wish to view
4
Installation Wall Mounting Electrical Connection Tubing
Conductive Probe
5
Wall Mounting Unpack the Titan
Remove mounting plate from Titan (Remove screw and slide plate down) Attach mounting plate to wall Replace Titan on the mounting plate (Replace screw)
6
Unpack Titan
7
Remove screw and slide Mounting Plate off (downward direction)
Removing Mounting Plate Remove screw and slide Mounting Plate off (downward direction)
8
Prior to mounting Titan Location should be based on:
Desired location of Titan and chemicals Electrical Connection for Titan Flat vertical surface away from splashing and steam originating from machine Titan should must be placed so that it can be easily observed and serviced
9
Attach to Surface
10
Follow instructions on Mounting Bracket
Replace Titan on Mounting Plate Follow instructions on Mounting Bracket
11
Electrical Connection
Connect power to the Titan per dish machines manufacture's recommendations. Constant power should be supplied to the Titan anytime the dish machine power is on. The Titan can also be plugged directly into a wall socket. Connect the Detergent Trigger to the machine.( If the Machine does not have a specific trigger connection, then the trigger should be wired to the coil of the Motor Contactor) Connect the Rinse Trigger to the Machine. (If the Machine does not have a specific rinse trigger connection, then the trigger should be wired to the Rinse Solenoid Valve)
12
Tubing Connections Tubing connection from the Titan to the Machine.
Tubing connection from the Titan to the Chemical.
13
Attaching the Bulkhead Fitting for the chemical injection of a liquid detergent.
Inside Outside Chemical injection fitting must be above the water level in the tank Chemical Injection fitting should be directly above Conductive Probe
14
Installing Conductive Probe
Inside Outside The Probe should be installed 2/3 down from water level of the tank The probe should be installed directly below chemical injection
15
Click here to return to Main Menu
Press Enter to continue to Initial Programming
16
Enduser accessable menu
Initial Programming Enduser accessable menu
17
Changing Languages Press to get to language screen
Press to start edit screen Press or to change languages Press to accept change
18
Pump will run for 2 minutes if it is not stopped manually
Detergent Prime Press to scroll to Detergent Prime Press to start priming Press again to stop priming Pump will run for 2 minutes if it is not stopped manually
19
Pump will run for 2 minutes if it is not stopped manually
Rinse Prime Press to scroll to Rinse Prime Press to start priming Press again to stop priming Pump will run for 2 minutes if it is not stopped manually
20
Pump will run for 2 minutes if it is not stopped manually
Sanitizer Prime Press to scroll to Sanitizer Prime Press to start priming Press again to stop priming Pump will run for 2 minutes if it is not stopped manually
21
Detergent Status Display
Press to display Status C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading T – Recharge + Titan is feeding detergent - Titan is not feeding detergent * Screen will stay active for 30 minutes until the up or down arrow is pressed or 30 minutes lapse
22
Rack Count Rack Count 00000 This is a read only record
23
Descale Press to start Press again to stop
24
Click here to return to Main Menu
Press Enter to continue to System Access
25
System Access System Access is only available after Initial Programming is completed
26
Enter Code
27
Dispenser SetupParameters
28
Control Mode
32
Use to enter letters
33
Use to adjust volume
43
Click here to return to Main Menu
Press Enter to continue to Diagnostic Mode
44
Diagnostic Mode
45
Sanitizer Level Detergent Level Rinse Level
46
C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor
P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading T – Recharge + Concentration mode - not Concentration mode * - When a trigger is present
47
Rinse Status Screen L – Liquid D - Dry D – Delay R – Rinsing L – Limit
Reached Rinse Alarm Set Point Rinse Sensor Reading
48
Sanitizer Status Screen
Sensor Reading Liquid + - running - - not running Sanitizer alarm set Point
49
Displays total switchover count for OVER and Under feeding
Displays total switchover counts for An open probe or shorted probe
50
Now the Titan is Setup and ready for use.
Click here to return to Main Menu Press enter to veiw Accessories
51
Accessories Magnetic Field Reader Inductive Warewash Probe
(Click on one of the following) Magnetic Field Reader The DEMA Magnetic Field Reader eliminates the need to make wire connections to warewash and laundry machines. The DEMA Magnetic Reader detects the presence of the magnetic field surrounding an AC solenoid valve or Ac motor. This may then be used as a trigger signal to a DEMA warewash or laundry dispenser. Inductive Warewash Probe The DEMA Inductive Warewash Probe replaces the conductivity probe used to sense detergent concentration in the wash tank. The advanced technology of the DEMA Inductive Warewash Probe allows the wash tank conductivity to be sensed without any metal contacting the wash tank solution. As a result, the DEMA Inductive Warewash Probe is immune to contaminants, such as lime, which plate onto conductivity probes.
52
DEMA Magnetic Field Reader
Disconnect the power from the Titan and the warewash machine. Disconnect rinse or wash trigger cable ( ) from the Titan control board ( ). Route the Magnetic Field Reader cable as shown on next page in to the Titan enclosure. Plug the Magnetic Field Reader cable into rinse or wash trigger connector on the Titan control board ( ). With the door on the Titan fully open; secure the Magnetic Field Reader cable in the bottom plate of the Titan with strain relief ( ). Close the door on the Titan. Place the Magnetic Field Reader against the coil of the solenoid valve or motor housing to be used for sensing. The sensing element is on the bottom side of the Magnetic Field Reader below the point of the arrow that is on the top. Secure the Magnetic Field Reader in place with the Hook & Loop strap. The strap may be trimmed as required. Turn the power on the Titan. Turn on the power to the warewash machine. Energize the solenoid valve or motor to which the Magnetic Field Reader is attached. After one second a green LED on the Magnetic Field Reader should illuminate next to the cable. If it does not illuminate, reposition the sensor until it does.
53
DEMA Magnetic Field Reader
De-energize the solenoid valve or motor. The green LED should turn off after one second. If it stays on, reposition the sensor. When properly installed the green LED will turn on one second after the solenoid valve or motor which it is attached is activated. It will turn off one second after deactivation.
54
Inductive Warewash Probe
Disconnect the power from the Titan and the warewash machine. Drain the warewash machine Disconnect the probe wire from the Titan control board and remove the conductivity probe from the tank. Install the DEMA Inductive Warewash Probe in the wash tank, through the wall shown on next page. The hole through the center of the DEMA Inductive Warewash Probe must be vertical. Route the DEMA Inductive Warewash Probe cable, as shown on the next page, into the Titan enclosure. The connector and strain relief fit the ¾” hole in the bottom-center access panel of the Titan enclosure. Plug the DEMA Inductive Warewash Probe cable into the white eight pin connector on the Titan control board ( ). The connector is directly above the microcontroller chip. With the door on the Titan fully open; secure the DEMA Inductive Warewash Probe cable in the bottom plate of the Titan with strain relief ( or-3). Close the door on the Titan. Turn on the power to the Titan Turn on the power to the warewash machine.
55
Inductive Warewash Probe
NO. PART NUMBER DESCRIPTION 1 (Use either -2 or -3) Cable Strain Relief 5/8” Cable Strain Relief 3/4" 2 Inductive Probe Kit
56
TITAN INSTALATION KITS
TITAN ELECTRONIC KITS TITAN INSTALATION KITS
57
TITAN TECHNICAL SPECIFICATION
62
TITAN PARTS BREAKDOWN