Download presentation
Presentation is loading. Please wait.
Published byAlyssa McCullough Modified over 11 years ago
1
Titan EP Training For Modifying a Preprogrammed Titan EP August 11, 2009
2
Titan EP Features 100-260VAC 50/60Hz main power (constant power) 24-480VAC trigger signals Detergent pump output 10 oz./min (300ml / min) Rinse pump output 0.5 oz./min (16ml / min) Optional Items –Inductive probe –Magnetic field reader
3
Titan EP Button Functions LEFT arrow moves cursor to the left DOWN arrow decreases value or moves cursor down RIGHT arrow moves cursor to the right UP arrow increases value or moves cursor up ENTER button accepts values entered
4
Titan EP – Idle Screen Idle / Default screen shown when unit is not being programmed Press enter to advance to priming and programming functions Unit will return to this screen during programming if long delays are taken during programming Can be modified in programming
5
Titan EP – Detergent Prime 1 st screen seen after the idle screen Press enter to start & stop pump priming OR Use the UP & DOWN ARROWS to scroll through other menu selections
6
Titan EP – Rinse Prime Press enter to start & stop pump priming OR Use the UP & DOWN ARROWS to scroll through other menu selections
7
Titan EP – Sanitizer Prime Press enter to start & stop pump priming OR Use the UP & DOWN ARROWS to scroll through other menu selections
8
Titan EP – Information Screen DET –P = Probeless mode –C = Concentration mode SP –Not applicable for probeless mode –Detergent set point in concentration mode Input –Actual probe reading
9
Modify Program Probeless Mode Modify existing program for probeless mode For both door and conveyor machine types
10
Probeless Mode – Recharge Time Press ENTER to modify setting Use UP & DOWN arrows to adjust time setting (minutes & seconds) Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
11
Probeless Mode – Dwell Time For conveyor machine type only Press ENTER to modify setting Use UP & DOWN arrows to adjust time setting (minutes / seconds) Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
12
Probeless Mode – Dead Cycles For door machine type only Press ENTER to modify setting Use UP & DOWN arrows to adjust number of cycles between recharges Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
13
Probeless Mode – Initial Charge Press ENTER to modify setting Use UP & DOWN arrows to adjust time setting (minutes / seconds) Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
14
Probeless Mode – Charge Clock Defines time between trigger signals for an initial charge Press ENTER to modify setting Use UP & DOWN arrows to adjust time setting (hours / minutes) Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
15
Probeless Mode – Rinse Speed Adjust rinse pump speed Press ENTER to modify setting Use UP & DOWN arrows to adjust rinse speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens
16
Probeless Mode – Rinse Delay For door machine only – Adjust delay time to start rinse pump Press ENTER to modify setting Use UP & DOWN arrows to adjust rinse delay Press ENTER when desired rinse delay is displayed Press UP or DOWN arrow to advance to other screens
17
Probeless Mode – Rinse Limit For door machine only –sets maximum rinse pump run time Press ENTER to modify setting Use UP & DOWN arrows to adjust rinse limit (seconds) Press ENTER when desired rinse limit is displayed Press UP or DOWN arrow to advance to other screens
18
Probeless Mode – Rinse Alarm Press ENTER to modify setting Use UP or DOWN arrows to change between Active and Inactive Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
19
Probeless Mode – Sanitizer Speed Adjust sanitizer pump speed Press ENTER to modify setting Use UP & DOWN arrows to adjust sanitizer speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens
20
Probeless Mode – Sanitizer Alarm Press ENTER to modify setting Use UP or DOWN arrows to change between Active and Inactive Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
21
Probeless Mode – Detergent Control Mode Press ENTER to modify setting Use UP or DOWN arrows to change between probeless or concentration Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens
22
Probeless Mode - Machine Type Press ENTER to modify setting Use UP or DOWN arrows to change between Conveyor and Door Press ENTER when desired machine type is displayed Press UP or DOWN arrow to advance to other screens
23
Probeless Mode – Trigger Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Detergent/Rinse, Detergent Only or Rinse Only Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens
24
Probeless Mode – Company Name Up to 16 characters Press ENTER to modify setting Use LEFT & RIGHT arrows to move between characters Use UP & DOWN arrows to at adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens
25
Probeless Mode – Alarm Volume Sets volume of audible detergent alarm Press ENTER to modify setting Use UP or DOWN arrows to adjust volume Press ENTER when desired volume is reached Press UP or DOWN arrow to advance to other screens
26
Probeless Mode – Enter New Code Sets programming password (4 numbers) Press ENTER to modify setting Use LEFT & RIGHT arrows to move between numbers Use UP & DOWN arrows to at adjust each number Press ENTER when desired code is displayed Press LEFT arrow to confirm setting Press UP or DOWN arrow to advance to other screens
27
Probeless Mode – End Programming Press enter to exit programming
28
Modify Program Concentration Mode Modify existing program for concentration mode For both door and conveyor machine types
29
Concentration Mode – Concentration Set Point Press ENTER to modify setting Use UP & DOWN arrows to adjust concentration set point Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
30
Concentration Mode – Feed Rate Controls how quickly set point is reached, high feed rate can lead to over shooting Press ENTER to modify setting Use UP & DOWN arrows to adjust feed rate Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
31
Concentration Mode – Alarm Delay Amount of time before detergent alarm sounds Press ENTER to modify setting Use UP & DOWN arrows to adjust time setting (minutes / seconds) Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
32
Concentration Mode – Rinse Speed Adjust rinse pump speed Press ENTER to modify setting Use UP & DOWN arrows to adjust rinse speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens
33
Concentration Mode – Rinse Delay For door machine only – Adjust delay time to start rinse pump Press ENTER to modify setting Use UP & DOWN arrows to adjust rinse delay Press ENTER when desired rinse delay is displayed Press UP or DOWN arrow to advance to other screens
34
Concentration Mode – Rinse Limit For door machine only –sets maximum rinse pump run time Press ENTER to modify setting Use UP & DOWN arrows to adjust rinse limit (seconds) Press ENTER when desired rinse limit is displayed Press UP or DOWN arrow to advance to other screens
35
Concentration Mode – Rinse Alarm Press ENTER to modify setting Use UP or DOWN arrows to change between Active and Inactive Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
36
Concentration Mode – Sanitizer Speed Adjust sanitizer pump speed Press ENTER to modify setting Use UP & DOWN arrows to adjust sanitizer speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens
37
Concentration Mode – Sanitizer Alarm Press ENTER to modify setting Use UP or DOWN arrows to change between Active and Inactive Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens
38
Concentration Mode – Detergent Control Mode Press ENTER to modify setting Use UP or DOWN arrows to change between probeless or concentration Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens
39
Concentration Mode - Machine Type Press ENTER to modify setting Use UP or DOWN arrows to change between Conveyor and Door Press ENTER when desired machine type is displayed Press UP or DOWN arrow to advance to other screens
40
Concentration Mode – Trigger Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Detergent/Rinse, Detergent Only or Rinse Only Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens
41
Concentration Mode – Company Name Up to 16 characters Press ENTER to modify setting Use LEFT & RIGHT arrows to move between characters Use UP & DOWN arrows to at adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens
42
Concentration Mode – Alarm Volume Sets volume of audible detergent alarm Press ENTER to modify setting Use UP or DOWN arrows to adjust volume Press ENTER when desired volume is reached Press UP or DOWN arrow to advance to other screens
43
Concentration Mode – Enter New Code Sets programming password (4 numbers) Press ENTER to modify setting Use LEFT & RIGHT arrows to move between numbers Use UP & DOWN arrows to at adjust each number Press ENTER when desired code is displayed Press LEFT arrow to confirm setting Press UP or DOWN arrow to advance to other screens
44
Concentration Mode – End Programming Press enter to exit programming