1
Central Control Equipment
LBB3500/05 LBB3508/00 LBB4106/x0 01.Nov.06 DCN SA PO CCE
2
Central Control Unit (Com - port 1) LBB3500/05
9-pin Sub-D connector RS 232 for: Terminal mode Factory testing Diagnostics OR Camera Control 1 01.Nov.06 DCN SA PO CCE
3
CCU Trunk Communication Board (TCB-4)
1 Jumper X14 for service only 2 S14 DIP- switches 1 – 8 Com-port settings 3 S10 Push- button switch to reset the Central Control Unit during servicing. 4 Three LEDs (left to right) green/ yellow/ red. Normally the green/ yellow LEDs flash in sequence, indicating the software is running. Red LED illuminates during system reset. 5 S9 DIP- switches 1 – 8 System modes 6 Yellow LED indicates Digital Signal Processing (DSP) software is running. 7 Connector for multi- trunk board (used only in the multi- CCU) 8 Sockets for inserting flash EPROM (even) 9 Sockets for inserting flash EPROM (odd) Upgrade Kit 01.Nov.06 DCN SA PO CCE
4
CCU Trunk Communication Board (TCB-4)
10 SRAM back- up battery 3.6 V (life- time 5 years min.) 11 Jumper X13 Battery back up 12 Fuse 3.15 amp (delayed) 13 Connector for multi- trunk board (used only in the multi- CCU) 14 Serial RS232 Port 1 15 Serial RS232 Port 2 Upgrade Kit 01.Nov.06 DCN SA PO CCE
5
Central Control Unit (Com - port 1) LBB3500/05
CCU Protocol and Serial Port settings - Protocol based for using Allegiant Video Switchers. For location of DIP- switches see; Table 4.5 and 4.6 LBB 3500/ 05 Port 1 for Camera Control In a single (stand- alone) CCU system only one COM- port (Port 1) is available: Default settings are; • 8 data bits • No parity check • 1 Stop bit Installation The maximum cable length between the CCU and the ‘Allegiant Video Switcher’ should not exceed 5 m (16.4 ft). Where longer distances are required an ‘current-loop interface unit’ should be used to ensure correct transmission. I&O Manual 01.Nov.06 DCN SA PO CCE
6
TCB-4 DIP Switch Settings
(default) I&O Manual 01.Nov.06 DCN SA PO CCE
7
Central Control Unit (Audio I/O) LBB3500/05
1 2 3 1. Asymmetrical Recorder In- & Outputs 2. 2 Asymmetrical line input connectors 3. Symmetrical or 2 Asymmetrical line outputs 01.Nov.06 DCN SA PO CCE
8
Central Control Unit (Audio I/O) LBB3500/05
1. Tape/cassette recorder input and output (Cinch-type) Tape In Asym. nom. -33 dBV max. -3 dBV Tape Out Asym. nom. -33 dBV max. -3 dBV 2. 2 Asymmetrical line input connectors (Cinch-type) Line In Asym. nom. -18 dBV max. +12 dBV 3. Symmetrical/Asymmetrical line output connectors (Cinch-type) Line Out Sym. nom. -12 dBV max. +18 dBV Line Out Asym nom. -18 dBV max. +12 dBV 01.Nov.06 DCN SA PO CCE
9
Central Control Unit LBB3500/05 (Trunk Outlets)
1 2 Trunk 1. Red LED overload indicators 2. Trunk outlet used for loop-through of the trunk-line-cable 01.Nov.06 DCN SA PO CCE
10
Central Control Unit LBB3500/05 (Trunk Outlets)
PCF = 60 max. PCF = 90 max. Trunk outlets For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet - 90 PCF total for the three outlets of the CCU. 01.Nov.06 DCN SA PO CCE
11
Central Control Unit LBB3500/05
1. Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 2A (slow blow) 175 W 105, 115 V, 125 V AC. T- 4A (slow blow) Warning: All units must be powered via an earthed mains outlet. 1 115V-T4A/230V-T2A I&O Manual 01.Nov.06 DCN SA PO CCE
12
Extension Power Supply LBB4106/x0
Rear view 1. Trunk line cable 2. Overload indicators 3. Trunk outlets 4. Mains socket 1 3 4 2 01.Nov.06 DCN SA PO CCE
13
Extension Power Supply LBB4106/x0 (Trunk outlet / Tap-off ’s)
1.Red LED overload indicators 2.Trunk outlet used for loop-through of the trunk-line-cable 3.Tap-off outlets are used for trunk-cable splitting Trunk Tap-off 01.Nov.06 DCN SA PO CCE
14
Extension Power Supply LBB4106/x0 (Trunk outlet / Tap-off ’s)
For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: PCF per outlet - 180 PCF total for the three outlets of the EPS. Tap- offs For Trunk-cable splitting with regenerating the digital signal. Power handling capacity maximum PCF = 60 max. PCF = 180 max. 01.Nov.06 DCN SA PO CCE
15
Extension Power Supply LBB4106/x0
1. Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 4A (slow blow) 350 W 105, 115 V, 125 V AC. T- 5A (slow blow) Warning: All units must be powered via an earthed mains outlet. 1 115V-T4A/230V-T2A I&O Manual 01.Nov.06 DCN SA PO CCE
16
Audio Media Interface LBB3508/00
Rear view 1. Cinch Audio output sockets 2. XLR Audio output sockets 3. Trunk line cable 4. Overload indicators 5. Trunk outlets 6. Mains socket 2 1 5 6 3 4 01.Nov.06 DCN SA PO CCE
17
Audio Media Interface LBB3508/00 (Audio outputs)
1. 4 Asymmetrical Audio output connectors (Cinch-type) 2. 4 Symmetrical (transformer balanced) Audio output sockets (3-pin XLR) Output 1 Output 2 Output 3 Output 4 01.Nov.06 DCN SA PO CCE
18
Audio Media Interface LBB3508/00 (Audio outputs Levels)
4 Asymmetrical audio output Nom Max Interpreter floor & language dBV - 10 dBV Multiple floor and line output dBV dBV Delegate loudspeaker channel dBV + 2 dBV 4 Symmetrical Audio output Nom Max. . Interpreter floor & language dBV dBV Multiple floor and line output dBV +22 dBV Delegate loudspeaker channel +1 dBV +13 dBV 01.Nov.06 DCN SA PO CCE
19
Audio Media Interface LBB3508/00 (Trunk outlet / Tap-off ’s)
1.Red LED overload indicators 2.Trunk outlet used for loop-through of the trunk-line-cable 3.Tap-off outlets are used for trunk-cable splitting Trunk Tap-off 01.Nov.06 DCN SA PO CCE
20
Audio Media Interface LBB3508/00 (Audio outputs)
PCF = 60 max. Trunk outlet For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet - 90 PCF total for the three outlets of the AMI. Tap- offs For Trunk-cable splitting with regenerating the digital signal. Power handling capacity maximum PCF = 90 max. 01.Nov.06 DCN SA PO CCE
21
Audio Media Interface LBB3508/00
1. Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 2A (slow blow) 175 W 105, 115 V, 125 V AC. T- 4A (slow blow) Warning: All units must be powered via an earthed mains outlet. 1 115V-T4A/230V-T2A I&O Manual 01.Nov.06 DCN SA PO CCE
22
Central Control Equipment