Presentation is loading. Please wait.

Presentation is loading. Please wait.

MFE ENTERPRISES, INC. Magnetic Flux Leakage Above Ground Storage Tank Floors.

Similar presentations


Presentation on theme: "MFE ENTERPRISES, INC. Magnetic Flux Leakage Above Ground Storage Tank Floors."— Presentation transcript:

1 MFE ENTERPRISES, INC. Magnetic Flux Leakage Above Ground Storage Tank Floors

2 1) Electronics Module 2) Battery Box 3) Magnetic Bridge 4) Sensor Main Components: MFE 2412 Mark 2 Floor Scanner MFE ENTERPRISES, INC.

3 Alarm 30 12.54 Display Battery Gain Low High ON OFF ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 MFE ENTERPRISES, INC. MFE 2412 Mark 2 Electronics Module

4 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON 1 2 3 4 5 6 7 8 9 10 11 12 Bottomside Slot (Alarm Off) Alarm Reset OFF ON

5 MFE ENTERPRISES, INC. MFE 2412 Mark 2 Magnetic Bridge

6 Magnetic Field Through Air N S Magnetic Field Through Steel Floor Plate Sensor MFE ENTERPRISES, INC.

7 Floor Plate N S Sensor Magnetic Field Through Steel MFE ENTERPRISES, INC.

8 N S Floor Plate Sensor Corrosion Pit MFE ENTERPRISES, INC.

9 Floor Plate Corrosion Pit N S Sensor MFE ENTERPRISES, INC.

10 Floor Plate Corrosion Pit N S Sensor 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON Alarm Reset OFF ON MFE ENTERPRISES, INC.

11 Influence of Magnet Lift Off on Signal Amplitude Detection Threshold Detection Threshold A B MFE ENTERPRISES, INC.

12 Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC. MFE 2412 Mark 2 Effect of Magnet Lift Off

13 Influence of Sensor Lift Off on Signal Amplitude Detection Threshold Detection Threshold A B MFE ENTERPRISES, INC.

14 Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC. MFE 2412 Mark 2 Effect of Sensor Lift Off

15 Influence and adjustment for coatings Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.

16 Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC.

17 Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC.

18 Sensor Floor Plate Corrosion Pit N S Sensor 30 12.54 Display Battery Gain LowHigh ON OFF MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 Alarm Reset ON OFF ON 30 12.54 Display Battery Gain LowHigh ON OFF MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 Alarm Reset ON OFF ON Floor Coating MFE ENTERPRISES, INC.

19 Effects of plate curvature on signal amplitude Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.

20 Side to side effect on signal amplitude caused by plate curvature Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.

21 Scanner Wheelbase effect with curved surface Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.

22 Volumetric influence on signal amplitude A B Detection Threshold Detection Threshold C Detection Threshold MFE ENTERPRISES, INC.

23 Topside / Bottomside influence on signal Amplitude A B Detection Threshold Detection Threshold MFE ENTERPRISES, INC.

24 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON 1 2 3 4 5 6 7 8 9 10 11 12 Bottomside Slot (Alarm Off) Alarm Reset OFF ON

25 Alarm 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 OFF ON 1 2 3 4 5 6 7 8 9 10 11 12 Bottomside Slot (Alarm On)

26 Alarm 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 OFF ON 1 2 3 4 5 6 7 8 9 0 1 2 Bottomside Pit (Alarm Off)

27 1 2 3 4 5 6 7 8 9 0 1 2 Bottomside Defect w/ Topside Pitting (Alarm Off) 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON Alarm Reset OFF ON


Download ppt "MFE ENTERPRISES, INC. Magnetic Flux Leakage Above Ground Storage Tank Floors."