Download presentation
Presentation is loading. Please wait.
Published byLee Lutes Modified over 10 years ago
1
MFE ENTERPRISES, INC. Magnetic Flux Leakage Above Ground Storage Tank Floors
2
1) Electronics Module 2) Battery Box 3) Magnetic Bridge 4) Sensor Main Components: MFE 2412 Mark 2 Floor Scanner MFE ENTERPRISES, INC.
3
Alarm 30 12.54 Display Battery Gain Low High ON OFF ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 MFE ENTERPRISES, INC. MFE 2412 Mark 2 Electronics Module
4
30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON 1 2 3 4 5 6 7 8 9 10 11 12 Bottomside Slot (Alarm Off) Alarm Reset OFF ON
5
MFE ENTERPRISES, INC. MFE 2412 Mark 2 Magnetic Bridge
6
Magnetic Field Through Air N S Magnetic Field Through Steel Floor Plate Sensor MFE ENTERPRISES, INC.
7
Floor Plate N S Sensor Magnetic Field Through Steel MFE ENTERPRISES, INC.
8
N S Floor Plate Sensor Corrosion Pit MFE ENTERPRISES, INC.
9
Floor Plate Corrosion Pit N S Sensor MFE ENTERPRISES, INC.
10
Floor Plate Corrosion Pit N S Sensor 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON Alarm Reset OFF ON MFE ENTERPRISES, INC.
11
Influence of Magnet Lift Off on Signal Amplitude Detection Threshold Detection Threshold A B MFE ENTERPRISES, INC.
12
Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC. MFE 2412 Mark 2 Effect of Magnet Lift Off
13
Influence of Sensor Lift Off on Signal Amplitude Detection Threshold Detection Threshold A B MFE ENTERPRISES, INC.
14
Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC. MFE 2412 Mark 2 Effect of Sensor Lift Off
15
Influence and adjustment for coatings Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.
16
Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC.
17
Floor Plate Corrosion Pit Sensor MFE ENTERPRISES, INC.
18
Sensor Floor Plate Corrosion Pit N S Sensor 30 12.54 Display Battery Gain LowHigh ON OFF MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 Alarm Reset ON OFF ON 30 12.54 Display Battery Gain LowHigh ON OFF MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 Alarm Reset ON OFF ON Floor Coating MFE ENTERPRISES, INC.
19
Effects of plate curvature on signal amplitude Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.
20
Side to side effect on signal amplitude caused by plate curvature Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.
21
Scanner Wheelbase effect with curved surface Detection Threshold Detection Threshold Detection Threshold A B C MFE ENTERPRISES, INC.
22
Volumetric influence on signal amplitude A B Detection Threshold Detection Threshold C Detection Threshold MFE ENTERPRISES, INC.
23
Topside / Bottomside influence on signal Amplitude A B Detection Threshold Detection Threshold MFE ENTERPRISES, INC.
24
30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON 1 2 3 4 5 6 7 8 9 10 11 12 Bottomside Slot (Alarm Off) Alarm Reset OFF ON
25
Alarm 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 OFF ON 1 2 3 4 5 6 7 8 9 10 11 12 Bottomside Slot (Alarm On)
26
Alarm 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 OFF ON 1 2 3 4 5 6 7 8 9 0 1 2 Bottomside Pit (Alarm Off)
27
1 2 3 4 5 6 7 8 9 0 1 2 Bottomside Defect w/ Topside Pitting (Alarm Off) 30 12.54 Display Battery Gain LowHigh ON OFF Reset MFE 2412 Mk2 MFE ENTERPRISES INC 1 2 3 4 5 6 7 8 9 0 1 2 ON Alarm Reset OFF ON
Similar presentations
© 2024 SlidePlayer.com. Inc.