Download presentation
1
DCN Next Generation Open Interface
Control a meeting using Open Interface Microphones Voting All room settings 14.Mar.07 DCNNG Open Interface
2
Touch panel and interface box + custom made software
Touchscreen Control Activate Microphone Touch panel and interface box + custom made software 14.Mar.07 DCNNG Open Interface
3
Custom made SW for controlling DCN
Assigning applications Microphone control and mode selection Voting control and showing results Activating Attendance Registration 14.Mar.07 DCNNG Open Interface
4
Page for selecting DCN voting modes
14.Mar.07 DCNNG Open Interface
5
Control equipment from AMX & Crestron
14.Mar.07 DCNNG Open Interface
6
Bosch Security Systems BV is not supplying touch screen equipment.
How to handle Bosch Security Systems BV is not supplying touch screen equipment. Contact AMX or Crestron dealer locally. React proactive. Select the dealer which has experience and is dealer for Bosch and AMX or Crestron. 14.Mar.07 DCNNG Open Interface
7
Synoptic Panel Control
14.Mar.07 DCNNG Open Interface
8
Remote Controller with Single CCU
Authorization Code for Open Interface (LBB4187) needed. Register your CCU online together with the authorization code to get a license key. Connect PC to Port 1 of the CCU Baudrate Protocol Full Enter License key into the CCU using the Download and License Tool. Download & License Tool 14.Mar.07 DCNNG Open Interface
9
Remote Controller with Single CCU
Configure Port 1 of the CCU for Simple Protocol. Connect Open Interface Device to Port 1 of the CCU Baudrate Protocol Simple Open Interface protocol ready for use. Open Interface Open Interface Device 14.Mar.07 DCNNG Open Interface
10
Open Interface Applications
(SC) System Configuration (SI) System Installation (DB) Database (MM) Microphone Management (VT) Voting (AT) Attendance Registration (MD) Message Distribution (IN) Simultaneous Interpretation (IC) Intercom (LD) Text Status Display (CC) Camera Control 14.Mar.07 DCNNG Open Interface
11
CCU Units System Structure Open Interface RS232 SC SI DB MM VT IN MD
AT IC LD CC ACN Units 14.Mar.07 DCNNG Open Interface
12
Communication The communication between the CCU and the remote controller is message based (remote functions and update notification). 14.Mar.07 DCNNG Open Interface
13
DCN Open Interface (DOS) Tool (CCU_DDTK.EXE)
Support & Information DCN Open Interface (DOS) Tool (CCU_DDTK.EXE) Open Interface Documentation Protocol Description Open Interface Commands 14.Mar.07 DCNNG Open Interface
14
Open Interface Documentation
All information which is needed to make an Open Interface program is described in the Open Interface Documentation. 14.Mar.07 DCNNG Open Interface
15
DOS-based (also Windows DOS-Box)
CCU_DDTK tool DOS-based (also Windows DOS-Box) Uses Simple or Full protocol for communication Full has handshaking Simple no handshaking Definition file (fnid.def) with: Names Function number Input and/or output structures 14.Mar.07 DCNNG Open Interface
16
System setup Open Interface Training
DCN-CCU Central Control Unit RS-232 DDTK PC Chairman Unit ID 1 Del. without LCD ID 2 Del. with LCD ID 3 Del. with LCD & CR ID 4 14.Mar.07 DCNNG Open Interface
17
Install the DDTK Toolkit CCU_DDTK -PS -S1:19200
Hands On Install the DDTK Toolkit CCU_DDTK -PS -S1:19200 Note : FNID.def file and CCU_DDTK.exe should be in the same folder. 14.Mar.07 DCNNG Open Interface
18
Practice 1 System Configuration
Collect System configuration Use Open Interface document for SC-commands and parameters explanation Use following commands: SC_C_START_APP SC_C_GET_CCU_VERSIONINFO SC_C_GET_CCU_CONFIG 14.Mar.07 DCNNG Open Interface
19
Practice 2 System Configuration
Fill DB with your name residing on a unit Check it with MM Speakers info on LCD. Use following commands to fill Database with one record: DB_C_START_APP DB_C_MAINT_CCU_DB “Test” 14.Mar.07 DCNNG Open Interface
20
Practice 3 System Configuration
Add your neighbor to another unit and do not give him voting authorization Check by running a voting round Use Following commands: DB_C_CCU_APPLY_ONE DB_C_STOP_APP SC_C_STOP_APP 14.Mar.07 DCNNG Open Interface
21
Practice 4 System Installation
Try behavior of SI functions : SC_C_START_APP SI_C_START_INSTALL 1 SI_C_SELECT_UNIT 1 1 (turns Unit 1 on) SI_C_SELECT_UNIT 2 1 (turns Unit 2 on) SI_C_SELECT_UNIT 2 0 (turns Unit 2 off) SI_C_STOP_INSTALL SC_C_STOP_APP 14.Mar.07 DCNNG Open Interface
22
Practice 5 Microphone Management
Start MM on DDTK and check behavior Remote controller Turn On/Off Microphone Add delegate to request list Change Max number of speakers Change Microphone mode to override MM_C_START_MM MM_C_SET_MICRO_ON_OFF 1 1 MM_C_SPK_APPEND 3 MM_C_RTS_APPEND MM_C_SET_ACTIVE_MICS 3 MM_C_SET_MIC_OPER_MODE 2 MM_C_STOP_MM 14.Mar.07 DCNNG Open Interface
23
End voting time = 10 seconds Flashing secret response
Practice 6 Voting Prepare YES/NO voting End voting time = 10 seconds Flashing secret response Use present key for presence No Notifications Results not Compressed Show result on stop voting 14.Mar.07 DCNNG Open Interface
24
VT_C_SET_GLOBAL_SETTINGS 2 1 0 0 0 0 1 0 0 0
Suggestion VT_C_START_APP Preparation: VT_C_SET_GLOBAL_SETTINGS VT_C_SET_VOTINGPARAMS VT_C_DOWNLOAD_SUBJECT 234 “Voting Test” “Mymotion” Execution: VT_C_START_VOTING VT_C_HOLD_VOTING VT_C_GET_RESULTS VT_C_RESTART_VOTING VT_C_STOP_VOTING 1 VT_C_STOP_APP 14.Mar.07 DCNNG Open Interface
25
Header Message Checksum Header and Checksum are protocol dependent!
Protocol Layout Header and Checksum are protocol dependent! Header Message Checksum 14.Mar.07 DCNNG Open Interface
26
Simple Protocol VS Full Protocol
Checksum over messages No acknowledgement No retransmissions No line checking Controller can check use SC_C_CHECK_LINK function Full Protocol Line checking Starts after first message Acknowledge of message reception Retransmissions on failures We will use Simple Protocol in this training! 14.Mar.07 DCNNG Open Interface
27
Header Message Checksum ESC $ CR
Protocol Layout Header Message Checksum ESC $ CR The header has a fixed length and forms a leader to recognize the start-point of a message ESC value = 0x1B ‘$‘ value = 0x24 CR value = 0x0D 14.Mar.07 DCNNG Open Interface
28
Header Message Checksum Type Length Data Protocol Layout
Currently the following types are defined for communication with the CCU: MDSM_REMOTEPROCEDURE_REQ : Always transmitted to the CCU. MDSM_REMOTEPROCEDURE_RSP : Respons back from the CCU MDSM_NOTIFY : Notification from the CCU 14.Mar.07 DCNNG Open Interface
29
Header Message Checksum Type Length Data
Protocol Layout Header Message Checksum Type Length Data Defines the actual length of the data present in the array following. Only this amount of data of the ‘byData’ array is transmitted. 14.Mar.07 DCNNG Open Interface
30
Header Message Checksum Type Length Data
Protocol Layout Header Message Checksum Type Length Data The actual function (+ if necessary some parameters) or notification which has to be sent or received. 14.Mar.07 DCNNG Open Interface
31
Header Message Checksum Checksum Byte
Protocol Layout Header Message Checksum Checksum Byte The Checksum is calculated using the following sequence: Sum all bytes over the header and the message. Take modulo 256 of the calculated checksum and do a bitwise invert of the checksum. This calculated checksum is sent along with the packet. The receiver executes the same calculation and verifies the calculated checksum with the received checksum. 14.Mar.07 DCNNG Open Interface
32
Packing a request message
Header Message Chk Checksum Calculation 1b 24 0d 03 04 00 30 1c == 09F 9F hex ESC $ CR 03 04 00 30 00 1C 00 60 Type Length 28 MM_C_SPK_APPEND Inverse 60 14.Mar.07 DCNNG Open Interface
33
Unpacking a response message
Header Message Chk 03 04 00 30 00 00 00 params Type Length Error code MM_C_SPK_APPEND 14.Mar.07 DCNNG Open Interface
34
Unpacking a notification
Header Message Chk 05 04 00 0E 00 1C 00 Type Length MM_C_SPK_APPEND_ON_PC 28 14.Mar.07 DCNNG Open Interface
Similar presentations