1 Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008

2 EIF FILTRES French compagny specialized since 30 years in filtration equipments and sampling treatments. January 30,2008 IFPAC 2008 – Baltimore January 29,2008

3 Our philosophy:  Leave the contaminants in process  Separate as fast as possible the contaminants from the sample  Reduce the treated volumes  Reduce and make easier the maintenance January 30,2008 IFPAC 2008 – Baltimore January 29,2008

4  Cross flow filtration with blow back systems  Liq/liq coalescing filter with jet fuel separator  Gas treament column  L Type housings  Modular and smart systems For that, we have developed : IFPAC 2008 – Baltimore January 29,2008

5 Realisations IFPAC 2008 – Baltimore January 29,2008

6 Realisations IFPAC 2008 – Baltimore January 29,2008

7 COALESCING FILTER GAS EJECTOR SEPARATOR VISCOSITY-DENSITY SENSOR BLOW BACK SYSTEM EIF TOPWORK COMPONENTS ISA/ANSI S 76.00.02 Compliant

8 Petrochemical application IFPAC 2008 – Baltimore January 29,2008

9 Typical gazoline sampling in front of Chromatograph IFPAC 2008 – Baltimore January 29,2008

10

11 Specifications :  Fluid : gazoline  Filtration needed  liquid-liquid coalescing needed IFPAC 2008 – Baltimore January 29,2008

12 New design in beginning of 2006  Cross flow filtration with blow back system  modular Intraflow assy  liquid-liquid coalescing with separator  Pneumatic control ( specific for the test) IFPAC 2008 – Baltimore January 29,2008

13 Gazoline sampling for sulphur analyzer IFPAC 2008 – Baltimore January 29,2008

14 TM Cross flow filtration Blow back system DECLIF HP MINI (low dead volume) To analyzer via Intra flow Fast loop Cross flow filter 2S2LIF GM MINI 2 microns (low dead volume) IFPAC 2008 – Baltimore January 29,2008

15 TM Gazoline treatment Séparator Coalescing housing IFPAC 2008 – Baltimore January 29,2008

16 first installations comments  Flow sheet needed  Free space needed around components with maintenance ( filters for example …)  How to install, vertically or horizontally  Drain and vent take into consideration IFPAC 2008 – Baltimore January 29,2008

17 The Answer !! IFPAC 2008 – Baltimore January 29,2008

18 3 D Solution IFPAC 2008 – Baltimore January 29,2008

19 The solution = 3D Patent Application Pending IFPAC 2008 – Baltimore January 29,2008

20 Video

21 The same sampling evolution IFPAC 2008 – Baltimore January 29,2008

22 TM  Compact  Top equipment easily accessible  Low dead volume Fast loop Astute SCF with tangential element 0,5 microns IFPAC 2008 – Baltimore January 29,2008

23 ASTUTE :  SP 76 compliant  Integrated cross flow filter  Modular  Compact  Low dead volume  Upgradeable IFPAC 2008 – Baltimore January 29,2008

24

25 ASTUTE :  Top equipment easily accessible  Vertical and horizontal position installation possible  On the fast loop or in derivation  All the different paths on the same module( sample, standard, drain, vent..) IFPAC 2008 – Baltimore January 29,2008

26 For the sampling:  Reduce or eliminate the sampling line  Decrease the response time  Reduce the product and drain volumes  Temperature control and heating easier  Reduce the sample contamination risk IFPAC 2008 – Baltimore January 29,2008

27 ASTUTE contribute to :  Measurement quality improvement  Cost of build and operating cost reduction  Maintenance easier  Installations sécurity improvement IFPAC 2008 – Baltimore January 29,2008

28 APPLICATIONS IFPAC 2008 – Baltimore January 29,2008

29 Moisture sensor Pressure regulator filter Flow meter IFPAC 2008 – Baltimore January 29,2008

30 TM ISOLATING VALVES PROCESS PIPE DIRECT CONNECTION ON PROCESS CCIMS CLAMPS CCIMS System IFPAC 2008 – Baltimore January 29,2008

31  Direct connection on process  Very short response time  Easy maintenance clamp connection  Low contamination level  Sampling reduction cost  No drain IFPAC 2008 – Baltimore January 29,2008

32 Thank you for your attention ! And welcome to our Booth 402 IFPAC 2008 – Baltimore January 29,2008