The Building Regulations (Northern Ireland) 2000 Part R Access to and use of Buildings Presentation for RSUA & CIAT Facilitators Laura Hillis – Belfast Building Control Patrick Hobson – SE Group Billy Gillespie – NE Group
3
Part R Programme Introduction Part R and dwellings Part R and buildings which are not dwellings Access to and within buildings Facilities and Services in buildings Some Examples
4
3 Disabling Conditions *Physical *Sensory *Cognitive *Aging *Hidden *Temporary *Encumbered
5
4 Some Numbers *19.4% (200,000) Registered Disabled *70% find Built Environment Aggressive *1/3 European population elderly *24,000 in NI with serious sight loss *201,000 in NI with hearing impairment
6
Evolution of Design
7
The Average Person Access for Disabled Universal Accessibility
8
Evolution of Design
9
What has brought about this change?
10
Change agents
12
LEGISLATION Chronically Sick and Disabled Persons Act 1978 Disabled Persons Act 1982 Building Regulations 1994/2000 Disability Discrimination Act Equality Commission for N. Ireland
13
The need for Regulation The provision of advice, guidance and persuasion over a number of years have not raised awareness of designers and house builders to substantially improve access to dwellings for disabled people. There does not therefore appear to be an effective alternative to Regulations Department of the Environment
14
Positive Enforcement Regulation is probably the most potent weapon in the drive towards an accessible environment for all.
15
14 Part R of the Building Regulations Access to and use of buildings
16
Principles of Part R Part R - Access to and use of buildings PEOPLE, including parents with children, elderly people and people with disabilities, should be able to: visit new dwellings and use principal storey…cope better…stay put longer in own homes... Secretary of State
17
16 WHAT MUST BE PROVIDED R2 - Reasonable Access - to/into/within and to use the building & facilities R3 - Reasonable Access to extensions R4 - Sanitary accommodation in extensions (not dwellings) R5 - Sanitary conveniences in dwellings R6 - Deemed-to-satisfy – R2,R3,R4 & R5 Technical Booklet R 2006 Dept. Ed. & Emp. Bld. Bulletin 91
18
GUIDING PRINCIPLE Make as many new buildings as possible accessible to everyone
19
Definitions of disability Building Regulations Now no reference to disability Previously defined as :- Physical impairment that affects mobility Impairment of hearing or sight Disability Discrimination Act Different definition
20
Goals of the regulations for Dwellings To make reasonable provision for people to :- –reach the principal entrance from the point of entry –have access into and within the entrance storey or principal storey –have access to a sanitary convenience
21
Stage 1 - The Approach Technical Booklet R 2006 Section 7
22
Point of entry Principal entrance Point of entry Approach to principal entrance or common entrance
23
Approach to Dwellings The approach from point of entry to principal entrance –Level Firm and even surface Maximum gradient 1:20 Minimum width 900mm –Ramped Maximum gradient 1:12 for length < 5m Maximum gradient 1:15 for length < 10m 1200mm long landings –or a combination
25
Steep sites Steep plot gradient to Principal Entrance (greater than 1:15 or 1:12 < 5m travel distance) –an alternative entrance can be used Plot gradient to Alternative Entrance (greater than 1:15 or 1:12 < 5m travel distance) – a stepped approach can be used
26
Point of entry Route of travel Alternative entrance Principal entrance Approach to alternative entrance
27
Stepped Approach In addition to Part H requirements Width = 900mm min. Rise = 150mm max. (75mm min) Going = 280mm min. Flight = 1800mm max. (16 steps max) Landing = 900mm min. length Closed tread profile Suitable handrail when >2 risers
28
Stage 2 - The Entrance Technical Booklet R 2006 Section 7
29
Principal Entrance Landing –level for 900mm Entrance door –775mm clear width ( i.e. 29 door) Level threshold –proprietary details
30
PVC door threshold
32
Stage 3 - Horizontal circulation within the dwelling Technical Booklet R 2006 Section 8
33
Circulation within dwelling In most cases –Access to all habitable rooms and a toilet on the entrance storey No habitable rooms on the entrance storey? –Access to all habitable rooms and a toilet on the principal storey
34
Width of circulation routes
36
Stage 4 - Vertical circulation within the dwelling Technical Booklet R 2006 Section 8
37
Internal stairs Changes in level within an entrance storey Between an entrance storey and a principal storey Requirements –900mm clear width –Suitable handrail to both sides including landings
38
Internal stairs
39
Stage 5 - Common Stairs and Lifts in Apartments Technical Booklet R 2006 Section 9
40
Apartments - what else is needed? Approach, entrance door, threshold –as per dwellings, to the common entrance Common circulation routes –1200mm minimum width –level or ramped
41
Apartments - common ramps Ramps –1200mm width (1000mm between handrails) –max 10m length at 1:15 –max 5m length at 1:12 –1200mm landings –handrails both sides over 2m
42
Apartments - common stairs Common stairs –contrasting nosings –1000mm clear width –170mm maximum risers –250mm minimum goings –closed profile –1200mm landings –suitable handrails to each side
43
Apartments - is a lift needed? No - but if provided, then –800mm doors –900mm x 1250mm car size –controls (900-1200+400) –Visual/audible indication over 3 stories –Call signalling and 5s dwell –1500mm x 1500mm landing –400kg loading
44
Stage 6 - Access to Toilets Technical Booklet R 2006 Section 10
45
Toilet Access Access should be provided to a toilet on the Entrance Storey or the Principal Storey as appropriate
46
Toilets WHB can project into the clear space Door swing must not obstruct clear space Door width is already determined by circulation route width 450 mm 750 mm 400 mm Frontal access
47
Toilets The doorway shall be located so that its edge is not in front of, or >250mm behind, the WC…… 250 mm 500 mm400 mm 750 mm Oblique access
48
Stage 7 - Heights of switches Technical Booklet R 2006 Section 11
49
Switch positions Switches, socket outlets etc. –zone between 450 to 1200mm above floor level
51
Case 1