Ventilation of Confined Spaces
2
Confined Space Ventilation
Confined spaces are not normally designed for convenient ventilation Must take steps to: ensure air is breathable before entering confined space maintain acceptable air quality in the confined space during entry
3
Hotwork in Confined Spaces
Presents additional ventilation challenges in confined spaces Includes torch cutting, welding, brazing and soldering, arch gouging
4
Hotwork in Confined Spaces
Remember… confined spaces concentrate hazards! Hotwork can create atmospheric hazards in confined spaces from fumes, gasses and vapors Effective ventilation sometimes may only be accomplished by mechanical ventilation
5
Natural Ventilation in Confined Spaces
“Chimney Effect” convection process created by temperature changes Occurs by sunlight heating vessel walls and air within If there is an opening in bottom and top of vessel, upward draft created
6
Natural Ventilation Problems
Confined spaces rarely experience uniform thermal conditions Various sources of heat in confined spaces human bodies lighting hotwork processes
7
Natural Ventilation Problems
Factors such as sunlight, body heat, lighting and hotwork are usually not sufficient to move enough air to provide an acceptable atmosphere
8
Overcoming Natural Ventilation Problems
Must establish techniques and procedures to provide adequate ventilation It is easier to work with than against natural convection.
9
Use of Mechanical Ventilation
Properly installed, can reduce or eliminate respiratory protection requirements Effective engineering controls usually less dependent on worker attention than respiratory protection
10
29 CFR When feasible, effective engineering controls must be used rather than respirators
11
When is ventilation necessary?
If atmosphere: contains insufficient oxygen or is oxygen rich contains flammable dusts or vapors contains hazardous or toxic vapors, mists, fumes, gases, or fibers
12
When is ventilation necessary?
If atmosphere: is subject to activities that may generate hazardous mists, vapors, fumes or gases, or may create either an oxygen deficiency or oxygen excess, and increases heat stress on workers to unacceptable levels
13
CAUTIONS Many people resist wearing PPE, including respiratory protection Tangle of supplied air hoses in vessel with many welders can present a hazard
14
Ventilation- 29 CFR 1910.252(c) Spaces that require ventilation
work space less than 16 feet high volume less than 10,000 cubic feet per welder work areas with partitions, structural barriers, or other barriers that significantly obstruct airflow
15
Ventilation- 29 CFR 1910.252 Ventilation options:
provide at least 2000 cfm of airflow for each active welder; or provide each welder with a local exhaust device local exhaust devices must be capable of maintaining a velocity of 100 fpm toward the air intake
16
Ventilation Requirements
29 CFR and 29 CFR require use of local exhaust ventilation or supplied air respiratory protection when performing hotwork using certain substances
17
Ventilation Requirements
Fluorine compounds Zinc Lead Cadmium Mercury Beryllium (local exhaust and supplied air respirators are required)
18
Ventilation Requirements
Construction : chromium stainless steels (if using MIG processes)
19
Air Moving Devices Two types: Can be air, steam or electrically driven
Fans Venturi-type eductors Can be air, steam or electrically driven
20
Eductors Sometimes called “air horns”
Air powered and rely on venturi effects to move air
21
Criteria for Rating Air Movers
Free Air Delivery Effective Blower Capacity Quantity of air and air pressure required (air-driven devices) Electrical power requirements (electrically driven devices)
22
Factors Reducing Performance
Equipment components in confined space Maintenance/construction materials erected in space Obstructions in make-up air manway Insufficient number of make-up air manways
23
Factors Reducing Performance
More restrictions to overcome = less air moved Air moving into space equals amount of air leaving the space
24
Air Driven Devices- Poor Performance
Reduced pressure and volume to air driven devices from multiple users Excessively long air hoses
25
Increasing Performance
Supplemental air compressors dedicated to air mover use (air driven devices) Supplemental air compressors connected directly to plant air system Eliminate “short-circuiting” of airflow
26
Designing Ventilation Systems
Configuration, contents and tasks determine type of ventilation opening configuration properties of expected atmospheric hazards type of work being performed
27
Electrically Driven Centrifugal Fans
Designed to overcome higher static pressures Usually heavier than air-driven equipment Can be used remotely to reduce noise Due to power, can suck up debris
28
Local Exhaust Single manway vessels
Interior obstructions that create “dead spots” Lack of feasible way to attach air-moving device Work with toxic metals
29
Local Exhaust Effective only when it captures and removes welding fumes and gasses at the source as they are emitted 100 fpm capture velocity at the source of fumes or gasses
30
Local Exhaust- Considerations
Long runs reduce airflow Airflow loss minimized by use of smooth ducting with large radius bends Run flexible ducting as straight as possible Consider using plenums for multiple welders Field test flow/personal air monitors
31
Make-up air quality Mechanical ventilation uses surrounding air
Make sure the make-up air is not a source of airborne contaminants
Similar presentations