Download presentation
Presentation is loading. Please wait.
Published byBrandy Fern Modified over 10 years ago
1
CeAnn Chalker ceann@chalker.org
Boomilever B & C – CeAnn Chalker
2
Disclaimer This presentation was prepared using draft rules. There may be some changes in the final copy of the rules. The rules which will be in your published Rules Manual will be the official rules.
3
Boomilever Description
Students will design and build the most efficient cantilevered wooden structure (i.e. – lightest that holds the most weight up to 15 kg.)
4
Event Parameters Only 1 structure entered per team No Impound
Event Supervisor provides all assessment devices No separate or detachable pieces
5
More Event Parameters Testing maximum load 15 kg
Students must wear proper eye protection (ANSI Z87+) teams given a warning to obtain proper eye protection
6
Construction Parameters Main Structure
Boomilever is a single structure Made of wood bonded by glue
7
Construction Parameters Main Structure
Unlimited laminations by students is allowed No limit on the cross section size of individual pieces of wood
8
Dimension Cue Sheet
9
Construction Parameters Attachment Base
Attach to one or more mounting holes on the Testing Wall May not attach or hook on edge of Testing Wall No more than 1.3 cm thick 1.3 cm maximum Attachment Base
10
Construction Parameters Attachment Base
one or more parts made from any type or size of wood and wood products w/in the rules must be a permanent part of the Boomilever included in the mass of the structure
11
Boomilever Dimension Limits Horizontal Length
Measured from the face of the Testing Wall to the center of the Loading Block same for both Div. B & Div. C Between 40.0 cm – 45.0 cm 40.0 to 45.0 cm Test Wall Loading Block
12
Boomilever Dimension Limits Contact Depth
The lowest distance the Boom may have in contact with the Testing Wall below the centerline of the mounting holes Div. B – no more than 20.0 cm Div. C – no more than 15.0 cm Test Wall Center Line of Mounting Holes Contact Depth
13
Loading Block Accommodate a Loading Block – Loading Block must start –
5.0cm x 5.0cm x 2.0cm ¼ inch diameter center hole Loading Block must start – at any height above the bottom edge of the Testing Wall
14
Vertical Testing Wall
15
Vertical Testing Wall Provided by the Event Supervisor
Vertical, solid, rigid, smooth, low-friction surface At least 40.0 cm wide x 30.0 cm high, minimum ¾” plywood Three Mounting Holes for ¼” bolts Mounting Holes are centered approx. 5.0 cm below the top of the wall
16
Vertical Testing Wall – cont’d
Middle hole centered on the face of the wall Other 2 holes are 10.0 cm on either side of the center hole on the same horizontal line All measurements are taken from the center of each hole
17
Vertical Testing Wall – cont’d
Lines marked on the Testing Wall Centerlines of the holes Horizontal lower limit line below the centerline of the holes Div. B – 20.0 cm Div. C – 15.0 cm
18
Vertical Testing Wall – cont’d
Boom attached using: one, two, or three ¼” diameter x 7.62 cm (3”) minimum length bolts 19 cm (3/4”) O.D. flat washers wing nuts
19
Boomilever Testing Only Students are to handle their Boomilevers throughout measurement, setting up, and testing No alterations, substitutions, or repairs are allowed to the Tower after check-in
20
Boomilever Testing A ¼” threaded bolt, chain, S-hooks, and bucket will be suspended through the Loading Block
21
Boomilever Testing Students may adjust the structure until they begin loading the sand Structures tested with sand or sand like material Up to maximum 15 kg Teams are given 10 minutes to load the sand into the bucket
22
Boomilever Testing Ends
When maximum load is supported (15 kg) When failure of the structure occurs The inability of the Boomilever to carry any additional load Any part of the load is supported by anything other than the Boomilever When any part of the Attachment Base goes below the Lower Limit Line on the Testing Wall When 10 minute test time elapses
23
Boomilever Testing Load
Load Supported includes – Loading block Eyebolt Washer(s) Wing nut Bucket Sand Not pieces of the Boomilever!
24
Boomilever Scoring Highest Score wins Structural Efficiency
= Load Supported (grams)/Mass of the Structure (grams) Ties 1 – Lowest Boomilever Mass 2 – Least Contact Depth
25
Boomilever Scoring Tiers
Teams are ranked by the highest score within each Tier Tier 1 – Booms meeting all Construction Parameters and no Competition Violations Tier 2 – Booms with one or more Construction Parameters and no Competition Violations
26
Boomilever Tiers cont’d
Tier 3 – Booms with one or more Competition Violations Tier 4 – Booms unable to be loaded for any reason (including goggle violations) are ranked by lowest mass
27
Resources www.soinc.org www.scioly.org
Search cantilever designs/structures Search bridge, truss designs – concepts are adaptable to boomilever
28
Where Do We Start? Brainstorm – after Rules Review!
Research online – Cantilevers, Bridges, & Trusses Student drawn rough designs Discuss what might work
29
Where Do We Start? It’s All About Efficiency!
Mass Held/Mass of Structure Examples - 20 g structure holds all 15 kg 15000/20 = 750 15 g structure holds 12 kg 12000/15 = 800
30
Where Do We Start? Design & Draw
Draw designs on gridded paper Draw the thickness of the wood pieces Square and Level Mirror Sides/Matching Sides
31
Where Do We Start? Design & Draw
Measurements are within specs to the rules Bigger is always better than too small Tape to building board (that can take pins) Cover plans with – Clear packing tape, plastic wrap, wax paper
32
What Wood? Main Structure
Balsa has the highest strength to weight ratio Balsa has better tensile (pulling apart) strength than compression strength Balsa is very easy to work with Balsa is less expensive than other woods
33
What Wood? Attachment Base (Not Balsa)
Poplar, Bass, Spruce Heavier and stronger Will hold up better when bolted to the Testing Wall No need to use a large piece Consider using 1, 2, or 3 separate pieces just where the bolts attach
34
Bonding the Wood Pick your Glue with care! Use your Glue modestly!
Glue weight is a place to cut down on overall structure weight! Too much glue!
35
What Glue? Wood vs. Super Wood Glue - Dilute with water or rubbing alcohol (1:1) Longer to dry but doesn’t make the wood brittle More flexible, moves with the wood Super Glue with Accelerator – quick but can dry out the wood Rigid when dry
36
Boomilever - Tension Design
Tension - the pulling force exerted by a string, cable, chain, or similar solid object on another object Tension length is longer than the Compression length Load
37
Boomilever - Compression Design
Compression - a pushing force. Compression length is longer than the Tension length Load
38
Tensile Advantages Balsa’s Tensile strength is much greater than it’s Compression strength A Compression Boomilever must have longer and thicker main support beam(s) to support the same load (adds more weight)
39
Key to Boomilever Design
The Connection between the Boomilever and the wall Wall to center of the Loading Block Distance (40 – 45 cm). Contact Depth may not exceed 20.0 cm (Div B) or 15.0 cm (Division C)
40
Lap Joint One of the strongest Use as often as possible
Strengthens compression pieces by adding stiffness Flaw – only as strong as the face of the wood!
41
Butt Joint Not strong for tension members
Under Tension will pull apart Under Compression will stay together
42
Notched Joint Stronger than Butt Joint Less strength than a Lap Joint
Difficult to build
43
Gusset Joint Combine a Butt Joint with a Lap Joint
Lap another piece of wood at the joint Strong in both tension and compression
44
Additional Joints
45
Diagonals and Cross Bracing
Diagonal Pieces & Cross Bracing are important! Prevents structure from torquing/twisting Adds additional strength If the Cross Braces cross (make an X), Glue them at the X Glue here
46
Warren Truss
47
Right Triangles in Design
Pratt Truss Right Triangles in Design Slants Face Inward
48
Howe Truss Right Triangles in Design Slates Face Away from Center
49
K Truss Tough to Build!
50
Boomilever Trusses – Tension vs. Compression
Diagonals in Tension Diagonals in Compression Howe Truss Pratt Truss
51
Tension & Compression Loading Block Warren Truss Modified Warren Truss
52
Tension Design Loading Block
53
Tension Designs
54
Great Variation in Designs
59
Notice the use of dowel rods
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.