Download presentation
Presentation is loading. Please wait.
Published byAlexis Marquiss Modified over 10 years ago
1
New Magnetic Observatory Installation In Oaxaca, Mexico IAGA 2008 Golden, Colorado, USA Ivan Hrvoic, Enrique Cabral, Esteban Hernandez, Gerardo Cifuentes, Mike Wilson, Francisco Lopez
2
Overview Overview of SuperGradiometer Installation Introduction of Potassium dIdD Summary and Conclusions
3
Overview of SuperGradiometer Installation –Instrumentation –SuperGradiometer Features –SuperGradiometer Array –UNAM-GEM Cooperation –Site Location, Selection and Data –Sensor Installation –Sample of Data Records –Sensor Field Inclinations and Declinations
4
Instrumentation Most Sensitive Scalar Magnetometer Based on Optically Pumped Potassium Very high sampling (up to 20 samples / second) Designed for minimal heading error, high absolute accuracy and reliability
5
SuperGradiometer Features Delivers sensitivity needed for Short Base or Gradiometric work in Earthquake Studies Background noise is 50 fT for 1 reading / second Can increase sensitivity further by placing sensors at specific distances, say 50 to 100m, which gives 1 fT/m gradient sensitivity
6
3 sensors arranged according to terrain (horizontal or vertical) Sensor spacing up to 140m Long term integration is promising SuperGradiometer Array
7
UNAM-GEM Cooperation Geophysics Department of UNAM expressed interest in deployment in Mexico Discussions about experimental deployment of SuperGradiometer for Earthquake studies Site selection possibilities
8
Site Location: Oaxaca, Mexico
9
Site of Mexican Supergrad is at 1751171 latitude and 745773 longitude.
10
Site Location: Oaxaca, Mexico El Trapiche San Francisco Cozoaltepec Santa Maria Tonameca, Oaxaca
11
Site Selection: Survey Overhauser Gradiometer Survey
12
Site Selection: Data 30 pT Gradiometric Survey Map
13
Site Selection: Sensor Location
14
Sensor Installation: Pillars
15
Powering the System 14 Batteries = 420 Ah 23 Solar Panels = 920 watts (38 Ah)
16
Data Transfer Upstream 300 Kbps Static IP Address Initial Setup with Local and Base (not shown) Towers Currently upgrading to Satellite
17
SG Total Field record pT
18
SG Gradient 12 hr
19
SG Gradients record pT
20
Sensor Field Inclination and Declination Sensor 1: I = 43.16, D = 5.11º Sensor 2: I = 43.12º, D = 5.05º Sensor 3: I = 43.19º, D = 5.27º
21
Introduction of Potassium dIdD –Correction of Diurnals in Gradients & Israeli Experience –Potassium dIdD –Site Selection –Sensor Installation –Satellite View of Site –Experimental Results
22
Correction of Diurnals in Gradients & Israeli Experience Example of magnetic monitoring a) Difference G 21 = F 2 -F 1 b) Difference G 32 = F 3 -F 2 c) Y component of magnetic field d) X component of magnetic field e) Z component of magnetic field
23
Correction of Diurnals in Gradients & Israeli Experience Leveled SuperGrad differences after ‘cleaning’ procedure. a) Difference Gcorr 21 b) Difference Gcorr 32
24
Potassium dIdD GSMP-35 dIdD In the past, some magnetic observatories relied on a combination of Overhauser dIdD, and theodolite instruments for obtaining measurements. GEM introduces new GSMP-35 dIdD (delta Inclination / delta Declination) system for high precision results (maximum 5 readings per second, 15pT sensitivity at 1 reading per second). Now, the dIdD has been enhanced significantly with the development of the Suspended dIdD system with potassium sensor.
25
Site Selection: Survey
26
Site Selection: Data Gradient in dIdD 0.03 nT
27
Site Selection: Sensors Location The distance from dIdD to: Solar Panel 65 m SG/CPU 70 m Sensor 1 150 m Sensor 2 110 m Sensor3 80 m
28
dIdD Installation: Pillar
29
Satellite View of Site SG = SuperGrad console dIdD = dIdD system S1 = Sensor 1 S2 = Sensor 2 S3 = Sensor 3 Solar= Solar panels and batteries
30
Experimental Results
31
Summary and Conclusions We have tried to establish reference conditions to detect magnetic precursors of Earthquakes based on known precursors. While trying to eliminate influence of diurnal variations of magnetic field, a need for a high sensitivity measurement of components arose. We introduced a Potassium DIDD with some 15pT sensitivity, thus setting up possible new standards for a high sensitivity magnetic observatory
Similar presentations
© 2025 SlidePlayer.com. Inc.