Download presentation
Presentation is loading. Please wait.
Published byDraven Greenfield Modified over 10 years ago
1
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Your search is over SONO 3100 FUS380/FUE380 SONO 3300 SONO 3300 CT SONOKIT - Retrofit Dedicated Program SITRANS F US Clamp-on A wide selection of flowmeters – both wetted and clamp-on solutions - makes it simple for you to choose the best flowmeter for your application
2
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 2 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Two-track technology based on the transit time technique Direct shot sound transmission Optimum reliability and accuracy compared with e.g. Doppler meters Working principle Two-track sensor construction One of the keys to SITRANS F US flow meter precision performance is its direct shot ultra- sound transmission technique. It shoots ultrasound pulses directly to the receiving transducer without bouncing them off the interior walls of the pipe. This way, the presence of any scale build-up on interior pipe walls will not weaken or degrade transmitted signals. Dedicated Program SITRANS F US
3
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 3 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Transmitter FUS060 Ultrasonic flowmetering at its best Ideal for Oil, petrochemicals, power plants or water and wastewater Enclosure rating IP67/NEMA 4X/6 Communication via PROFIBUS PA, HART ATEX Approval, ATEX II 2 G EEx d (e)/(ia) ib IIC T6 FUS060 meets the requirements of the OIML R117 custody transfer standards FUS060 offers a repeatability of <±0.15% of flow SITRANS FUS060 - High performance for rugged industries SITRANS F US in-line ultrasonic flow meters SITRANS F US Wetted
4
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 4 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Sensor SONO 3100 Ideal for petro-chemical, water and treated waste water Available in two/four track versions Available in e.g. Carbon steel, Stainless steel, Duplex steel Change of transducer without process shut down Accuracy better than 0.5% of rate DN 100 to 300 AISI (standard) DN 350 to 1200 carbon steel (std) PN 6 – PN 40 Max 200 °C Flange transducer or O-ring types EEx d IIC T2-T6 SITRANS F US Wetted SITRANS F US in-line ultrasonic flow meters
5
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 5 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SITRANS FUS/E380 New battery or mains powered ultrasonic flowmeter dedicated to district heating, cooling, water, and utility Two track design for rough installation conditions Battery power up to 6 years+ DN 100 mm – 800 mm Comply with EN 1434 and OIML R 75 87 V - 250 V ac - Backup possibility No pressure drops Compact or remote mounting - Temperatures up to 200 °C - Compact version 120 °C Preset pulse output for heat meters Fast measuring sequence 20 Hz / 0.5 Hz (net/bat) SITRANS F US Wetted SITRANS F US in-line ultrasonic flow meters
6
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 6 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Sensor SONO 3300 Multi-purpose flow meter for water, treated waste water, district heating, HVAC Remote or compact versions Two track design for rough installation conditions Accuracy better than 0.5 % DN 50 to DN 150 cast iron DN 200 to DN 300 welded steel PN 10 – 40 Max 160 °C. IP 67 EEx d IIC T3-T6 SITRANS F US Wetted SITRANS F US in-line ultrasonic flow meters
7
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 7 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Sensor SONO 3300/3000 CT Special designed ultrasonic flow meter for district heating application Custody transfer - approved in many countries Choice of different transmitters (SONO 3000) Accuracy better than 0.5 % DN 50 to DN 1200 Q max : 15 - 6000 m 3 /h Mild steel St. 35 Temperatures up to 200 o C Flanged version PN 16/25/40 No pressure drop Outputs (analog, relay and frequency/pulse SITRANS F US Wetted SITRANS F US in-line ultrasonic flow meters
8
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 8 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SONOKIT is based on the same technique and performance as SONO 3000/3100, and available in sizes from DN 200 to DN 4000. SONOKIT offers a simple, accurate alternative to traditional flow meters. This practical ”mounting kit” contains everything you need to install a flow meter on an existing pipeline, with the help of a few ordinary tools. SONOKIT Ideal for water / treated waste water pipes > DN 200 Cost effective solution for retrofitting based on wetted transducers Retrofitting with/without process shut down! Automatic calculation of calibration data based on geometry data. SITRANS F US Wetted SITRANS F US in-line ultrasonic flow meters
9
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 9 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Tapping band Siemens Flow Instruments A/S also offer tapping band flowmeters for retrofitting non-weldable pipes (concrete and cast iron) Sizes DN 200 to DN 1800 Pressure rating PN 6 – PN 16 depending on size Retrofitting with/without process shut down Tapping band material AISI 316 stainless steel Supplied in 2/4/6 sections depending on pipe size SITRANS F US Wetted SITRANS F US in-line ultrasonic flow meters
10
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 10 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Siemens offers a comprehensive selection of clamp-on ultrasonic flow meters for Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical Paper & pulp Power & utilities SITRANS F US clamp-on ultrasonic flow meters SITRANS F US Clamp-on Ultrasonic Flow meters Delivering industry-leading performance SITRANS F US Clamp-on
11
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 11 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation F US 1010 Clamp-on Flow meters Ideal for measuring HVAC, power, water & waste water, natural & process gas, liquid hydrocarbons and other general industries. Patented WideBeam technology combines the advantages of the non-intrusive clamp-on technology with a high precision accuracy. SITRANS F US clamp-on ultrasonic flow meters Install easily without cutting the pipe or shutting down operation No periodic cleaning and no moving parts to wear or foul No pressure drop or energy loss Flow surveys or temporary installation Large pipe diameters up to 9140 mm (360”) Wide turn down ratios Ultrasonic clamp-on flow meters from Controlotron strengthens Process Instrumentation of Siemens SITRANS F US Clamp-on
12
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 12 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SITRANS FUE1010 Multi-purpose flow meter for HVAC and power industries Have built-in BTU calculators, measuring hot and chilled water Measure both flow and energy; don’t require a separate energy measurement system Offer dedicated and portable meters Accuracy ±0.5%...1.0% of flow, for velocities greater than 0.3 m/s (1 ft/s) Flow range 0...18 m/s (0...60 ft/s), bidirectional Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 6.4 mm...9.14 m (0.25”...360”) Communications RS232, MODBUS/ N2, modem SITRANS F US clamp-on ultrasonic flow meters SITRANS F US Clamp-on
13
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 13 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SITRANS FUS1010 and FUS1020 Ultrasonic flow meters engineered to measure applications found in municipal and industrial water and wastewater industries Offer high precision, quick installation and low maintenance Have transit-time and doppler modes of operation Accuracy better than 0.5 % SITRANS FUP1010 is available in a standard portable or rugged submersible portable enclosure. SITRANS FUS1020 is a basic flow meter that provides affordable high performance for many flow measurement applications. WideBeam Transit-Time operation is provided but Doppler SITRANS F US clamp-on ultrasonic flow meters SITRANS F US Clamp-on
14
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 14 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SITRANS FUH1010 Are ideal for crude oil, refined petroleum or liquefied gas applications Minimal maintenance with no moving parts to wear or foul and no pressure drop or energy loss 3 meter catagories: Interface detectors/density meters, Viscosity compensated volumetric flowmeter, and Standard volume (net) mass flowmeter Accuracy better than 0.5 % Repeatability ±0.15%...0.3% of flow, depending on version ±0.05 of API # for interface detectors/density meters Flow range ±12 m/s (± 40 ft/s), bi- directional Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 6.4 mm...9.14 m (0.25”...360”) Communications RS232, MODBUS, Ethernet, modem SITRANS F US clamp-on ultrasonic flow meters SITRANS F US Clamp-on
15
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 15 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SITRANS FUG1010 Ideal for most natural and process gas industry applications, including checkmetering, allocation, flow survey verification, production, and more. There is no need to cut the pipe or stop the flow External transducers do not require periodic cleaning No moving parts to wear or foul Eliminates the pressure drop or energy loss Wide turn-down ratio Accuracy 1%...2% of actual volume reading (higher accuracy is pipe condition and flow profile dependent) 7...10 bar (100...145 psi), typical Flow range ±30 m/s (± 100 ft/s), bidirectional Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 25 mm...1.52 m (1”...60”) Communications RS232 SITRANS F US clamp-on ultrasonic flow meters SITRANS F US Clamp-on
16
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 16 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SITRANS FUP1010 Ideal portable solution for plant surveys Easily moved from one job site to another A standard portable meter with a compact plastic IP40 (NEMA 12) enclosure intended for indoor use. A waterproof portable meter with an IP67/63 (NEMA 6/3R) enclosure ideal for outdoor use. Both meters operate with transit-time and doppler Flow range ± 12 m/s (±40 ft/s), bidirectional Accuracy ±0.5%...2% of flow, for velocities greater than 0.3 m/s (1 ft/s) Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 6.4 mm...9.14 m (0.25”...360”) Communications RS232 SITRANS F US clamp-on ultrasonic flow meters SITRANS F US Clamp-on
17
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 17 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation SITRANS F US applications Siemens delivers industry specific solutions for Off-Shore and On-Shore Installations Liquid Hydrocarbon Water & Wastewater Natural and Process Gas HVAC and Power Chemical Processes Pulp & Paper Irrigation Cryogenics SITRANS F US Applications
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.