Download presentation
1
M iniature circuit breakers to UL 489
On this page, only the title and product photos should be changed. Siemens Energy & Automation, Inc.
2
5SJ4…-.HG4. HG40 HG41 HG42 Siemens
3
Products Type Poles Range (A) Voltage Characte-ristics
Breaking Capacity According to norm HG40 "Same Polarity only" 1 6 – 63 A 120 / 240 V AC 60 V DC (1 pole) B, C & D 14 kA / 10KA UL489 HG41 1, 2, 3 0.3 – 63 A 240 V AC 60 V DC (1 pole) 125 V DC (2 poles) C & D HG42 0.3 – 40 A C Characteristic 480Y/277 V C &, D 10 kA 0.3 – 32 A D Characteristic Siemens
4
Accessories Product Description Planned for… According to norm
Auxiliary switches 1NC or 1NO April 2009 UL489 Fault signal contacts Shunt trips 12 – 60 V AC/DC 110 – 415 V AC 110 – 250 V DC April. 2009 Busbars 1, 2 and 3 phases with 6,12 and 18 pins Availability to be Announced Feeder terminals Busbar touch protection Siemens
5
ABB S201 K S200 U S200 UP S201 Z S2C-H6 RU S2C-S6 RU
6
Products and Accessories
Type Poles Range (A) Voltage Characte-ristics Breaking Capacity According to norm S 201 DC acc. to UL489A 1 1 – 25 A 60 V AC/DC K & Z 10 kA UL489A. With or without integrated auxiliary switch S 200 U 1, 2, 3, 4 0.2 – 63 A 240 V AC UL489 S 200 UP 1, 2, 3, 4 0.2 – 25 A 480Y/277 V AC ABB Product Model Description According to norm Auxiliary contacts 2SC-H6RU 1NO, 1NC UL489 Fault signal contacts 2SC-S6RU Shunt trips S2C-A1U 12 … 60 V AC/DC S2C-A2U 110 … 415 V AC 110 … 250 V DC Feeder terminals 2CL200489R500 Busbars 2CDL R16 (06,12,18) 6, 12, 18 pins
7
Moeller FAZ-RT (Ring-Tongue) FAZ-NA
8
Products Product Poles Range (A) Voltage Characteristics
Breaking Capacity According to Norm FAZ-NA 1, 2 and 3 0.5 – 20 A 277 V AC and 480Y/277 V AC C & D 10 kA UL489 25 – 40 A 240 V AC 1 2 – 40 A 125 V DC C UL489A FAZ-RT 277V AC and 480Y/277 V AC Moeller
9
Accessories Product Model Description According to Norm
Auxiliary contact or Auxiliary/Trip-indicating contact Z-NHK 300 V AC UL489 Z-IHK-NA 480Y/277 V A, Same Polarity, 1NO 1NC. Shunt trip FAZ-XAA-NA 110 – 415 V AC 12 – 110 V AC Padlock hasp IS/SPE-1TE Prevents reactivation of the device during maintenance Busbar Z-SV/UL-16/ 1P-1TE 6, 12 and 18 terminals. 80 A. max. 480V AC, 50/60 Hz; 96 V DC Handle locking devices ZV-BS-UL 3 pole busbar cover Extension Terminal Z-EK/35/UL max. 480 V AC, 50/60 Hz; 96 V DC Moeller
10
Manufacture Rockwell
11
Manufacture Products 240 V AC 30 – 40 A 10 kA Breaking Capacity UL489
C & D 96 V DC 0.5 – 40 A 2 48 V DC 1 277 V AC and 480Y/277 V AC 0.5 – 25 A 1,2 & 3 Bulletin 1489 According to norm Characte-ristics Voltage Range (A) Poles Product Rockwell
12
Manufacture Accessories Product Model Description According to norm
Lockout Attachment 1489-AALOA UL489 Auxiliary Contact 1489-AAHH3 2 A, 240 V AC. 0.5 A. 110 V DC UL489 Auxiliary/Signal Contact 1489-AAHS3 2 A, 240 V AC. 0.5 A, 110 V DC Shunt Trip Module 1489-AASTA1 110 … 415 V AC. 110 … 230 V DC 1489-AASTA2 V AC. 12 … 60 V DC Rockwell
13
Fingersafe protection
Ring tongue terminals Box lug Box lug/RT terminals Fingersafe protection C60N UL489A Schneider
14
Products Type Poles Range (A) Voltage Characte-ristic
Breaking capacity According to norm C60 N Box lug, C60 N Ring Tongue, C60 N Box lug/RT 1 0.5 … 35 A 120 V AC C & D 10 kA UL489 240 V AC 5 kA 2 and 3 60 V DC C 2 125 V DC 40 … 63 A 1, 2 and 3 0.5 … 20 A 480Y/277 V AC C60 UL489A 0.5 … 63 A UL489A Schneider
15
2 Ring Tongue Terminals, 2 Isolation Shrouds. 25 mm screws.
Accessories Product Model Description According to norm MX+OF Shunt trip + Aux switch 27118, 27110, CO 24, 48, , V AC. 24, 48 and 125 V DC UL489 MN Under voltage release 27108, 27106, 27107, 27105 24, 48, 120 and 240 V AC. 24 and 48 V DC OF Auxiliary Switch MG26925 V AC V DC (1CO) SD Alarm switch MG26928 V AC V DC Ring lug terminal kit 17400 2 Ring Tongue Terminals, 2 Isolation Shrouds mm screws. UL489A, UL1077, IEC Schneider
16
Techna
17
Products Type Poles Range (A) Voltage Characte-ristic
Breaking capacity According to norm JTEC 489 AC 1 A 277 V AC, 240 V AC, 240/120 V AC, 120 V AC. 125 V DC B, C, K & D 10 kA UL489 35 … 63 A 240 V AC, 240/120 V AC, 120 V AC 2 to 4 480Y/277 V AC, 240/120 V AC, 120 V AC. 250 V DC (for 2 poles only) UL498 35 … 6 3A 240 V AC, 240/120 V AC, 120 V AC V DC (for 2 poles only) Techna
18
Accessories Product Description According to norm N Pole Switch
32 A and 63A 240 V AC, 480Y/277 V AC UL489 Auxiliary Switches 1 CO. 2CO.1CO + 1SCO.1CO + 1S + 1TB 120 V AC, 240 V AC 3 A and 6 A Fault signal contacts Shut trips 12/24/48/110 V AC/DC, 60/120/230/277/400 V AC Under voltage releases Handle locking devices Black and yellow Techna
19
Altech L Series
20
Products and Accessories
Type Poles Range (A) Voltage Characte-ristic Breaking capacity According to norm L Series 1 0.2 – 32 A 120, 240, 277 V AC V DC C & D 10 kA UL489 35 – 63 A 120, 240 V AC V DC 2 to 4 120, 240 V, 480Y/277 V AC. 250 V DC (for 2 poles only). Ul489 120, 240 V AC V DC (for 2 poles only) Altech Product Description According to norm N Pole Switch 32 A and 63 A 240 V AC, 480Y/277 V AC UL489 Auxiliary Switches 1 CO. 2CO.1CO + 1SCO.1CO + 1S + 1TB 120 V AC 240 V AC 3 A and 6 A Fault signal contacts Shut trips 12/24/48/110 V AC/DC, 60/120/230/277/400 V AC Under voltage releases Handle locking devices Black and yellow
21
GE E2000
22
Products and Accessories
Type Poles Range (A) Voltage Characte-ristic Breaking capacity According to norm EP100 ULH 1 0.5 – 32 A 120 V AC B, C & D 10 kA UL489 2 and 3 240 V AC Product Description According to norm Series CB auxiliary switch and bell alarm 5 A 240 V AC UL489 Auxiliary switch and bell alarm Shut trip and under voltage release 110/415, 110/125, 24/60, 24/48 V DC Walls For use between – pole breaker of opposite polarity mounted side by side Padlocking bracket For use in cutting off numbers of poles needed GE
23
Eaton WMT
24
Products and Accessories
Type Poles Range (A) Voltage Characteristic Breaking capacity According to norm WMT 1 0.5 – 40 A 240 V AC B, C & D 10 kA UL489 Eaton Product Description Padlocking Attachment WMBL2 Padlock Key WPKEY
25
Competitive Summary Products Siemens ABB Moeller Rockwell Schneider
Siemens ABB Moeller Rockwell Schneider 120/240 V AC HG A 0.2-63A No 0.5-35A 240 V AC HG A 0.5-40A A 480/277 V AC HG A 0.2-25A 0.5-20A A 0.5 – 20A 60 V DC (1 pole) HG40/HG41/ HG42 1 - 25A 6 - 40A No 0.5 – 63A 125 V DC (1 pole) 2-40A 125 V DC (2 pole) HG41/HG42 250 V DC (2 pole) Summary
26
Competitive Summary Products Siemens Techna Altech GE Eaton Summary
Siemens Techna Altech GE Eaton 120/240 V AC HG A No 240 V AC HG A 0.2-63A 0.5-32A 0.5-40A 480/277 V AC HG A 0.2-32A 60 V DC (1 pole) HG40/HG41/ HG42 No No 125 V DC (1 pole) 125 V DC (2 pole) HG41/HG42 250 V DC (2 pole) 0.2-32A 35-63A Summary
27
Competitive Summary Accessories Siemens ABB Moeller Rockwell Schneider
Siemens ABB Moeller Rockwell Schneider Busbars Yes No Handle locking devices yes Auxiliary switches Yes (mar 09) Fault signal contacts Yes (feb 09) Shunt trips Under voltage releases N-Pole-switch Mounting Base Summary
28
Competitive Summary Accessories Siemens Techna Altech GE Eaton Summary
Siemens Techna Altech GE Eaton Busbars Yes No Handle locking devices yes Auxiliary switches Yes (mar 09) Fault signal contacts Yes (feb 09) Shunt trips Under voltage releases N-Pole-switch Mounting Base Summary
29
M iniature circuit breakers to UL 489
On this page, only the title and product photos should be changed. Siemens Energy & Automation, Inc.