STAND TEST 3MeV AB-PO-PH mars 2007Jean-Pierre ROYER POWER CONVERTERS AB-PO-PH ( Pulsed and High voltage converters) WHERE ARE WE ?

Similar presentations


Presentation on theme: "STAND TEST 3MeV AB-PO-PH mars 2007Jean-Pierre ROYER POWER CONVERTERS AB-PO-PH ( Pulsed and High voltage converters) WHERE ARE WE ?"— Presentation transcript:

1 STAND TEST 3MeV AB-PO-PH mars 2007Jean-Pierre ROYER POWER CONVERTERS AB-PO-PH ( Pulsed and High voltage converters) WHERE ARE WE ?

2 AB-PO-PH – mars 2007J.P. Royer AB-PO-PH SOURCE H- 1 High Voltage Converter (40kV, 15 mA, dc) 1 High Voltage Converter (65kV, 4 mA, dc) PLCs for converters 40 and 65 kV 1 Screen bias Converter 2 kV, 1A, dc 1 Grid bias Converter 500V, 500mA dc 1 Anode bias Converter (5 kV to 20 kV, 20A pulsed 2msec, I dc 20 mA) LEBT (SOURCE H-) 2 pulsed solenoids converters (1200A, 800 microsec., 2 Hz) 4 « LPSS » for steerer (70V, 10A bipolar, dc) 1 « LPS2 » for bending (50A, 35V, dc) CHOPPER LINE 11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz) 2 « LPSS » for steerer (35V, 20A, dc) KLYSTRON MODULATEUR Prototype AB-PO (100kV, 20A, 800 microsec, 2Hz) Indian collaboration (100kV, 20A, 800 microsec, 2Hz) Power converters summary STAND TEST 3MeV

3 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV SOURCE H- 1 High Voltage Converter (40kV, 10 mA, dc) 1 High Voltage Converter (65kV, 2 mA, dc) Technical Specification For DC High Voltage Power Converters Rated - 40 kV, 10 mA- 65 kV, 2 mA AB-POEDMS No.: 799586 DO  FUG, HEINZINGER, TECHNIX  order: TECHNIX 22 kFS ( 40kV 15mA + 65 kV 4 mA) delivery time ~ April 2007 PLC’s for converters 40 and 65 kV

4 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV

5 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV SOURCE H- 1 Screen bias Converter 2 kV, 1A, dc  order FUG 6384 Euros (similar LEIR) may 2007 1 Grid bias Converter 500V, 200mA dc  order FUG 3258 Euros (similar LEIR) may 2007 1 Anode bias Converter (5 kV to 20 kV, 20A pulsed 2msec, I dc 20 mA)  order capacitor 46 microf. 26 kV: delivery 11-6-2007  specification for “capacitors charging power converter” done and sent for DO (demand offer) FUG, Heinzinger, Technix: answer foreseen end of march, then order and manufacturing, cabling the cabinet at CERN with the different elements.

6 AB-PO-PH mars 2007J.P. Royer AB-PO-PH LEBT (SOURCE H-) 2 pulsed solenoid converters (1200A, 800 microsec., 2 Hz) STAND TEST 3MeV 2 power converters modified (ex septa EPA-PS) : -No matching transformer -Third harmonic to be modified and adjusted -Active filter must work for 800 microseconds -Modifications and adjustments on regulation loops and electronics.

7 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV CHOPPER LINE 11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz) Market survey and call for tender for consolidation Linac 2 and Stand Test 3 MeV :  Contract placed at OCEM. Delivery of 11 units foreseen for end May 2007  12 kFS / power converter (power and electronics)

8 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV CHOPPER LINE 11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz)

9 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV Example of current and voltage waveforms delivered by a maxidiscap on a LEIR magnet The flat top will be increase until 800 microsec. voltage current

10 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV  Maxidiscap E1 to E4 

11 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV LEBT (SOURCE H-) 4 « LPSS » for steerer (10A bipolar, dc) 1 « LPS2 » for bending (50A, 35V, dc) CHOPPER LINE 2 « LPSS » for steerer (20A, dc)  Power part: Delta power converters ordered and at CERN  Electronic crates and different electronics cards are in progress for manufacturing.

12 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV  LPSS LPS2 E5 to E6 

13 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV KLYSTRON MODULATOR 1-Indian collaboration (100kV, 20A, 800 microsec, 2Hz) 2-Prototype AB-PO (100kV, 20A, 800 microsec, 2Hz) It was foreseen to start the stand test 3MeV with the Indian modulator but now, due to the delay, the PO prototype will be installed for operation.

14 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV

15 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV MODULATOR PROTOTYPE -The most important parts have been ordered ( ex: capacitors, high voltage pulse transformer, power converters for charging capacitors and for filament heater, H.V. switch, etc…). - Mechanical assembling has begun. - Preliminary tests of components in lab are in progress. Planning: first tests with klystron foreseen 15-9-2007

16 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV Pulsed power converter for Klystron

17 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV Power converters AB-PO

18 AB-PO-PH mars 2007J.P. Royer AB-PO-PH STAND TEST 3MeV CONCLUSION for the different power converters: -Team PO/PH responsibility for 27 power converters ( High Voltage, pulsed or DC) -The planning is well followed to respect the general planning STAND TEST 3MeV. -Effort will be necessary to integrate, to test and to commissioning equipments -Permanent effort (mechanical design, manufacturing) for the high voltage pulsed power converter for klystron modulator. -Sometimes conflicts with other business: work for shut down, hardware test for start–up accelerators etc… So we continue to go ahead ……..