Presentation is loading. Please wait.

Presentation is loading. Please wait.

Round Robin II Calibration/Test Results Impact of Burner Tab and Intake Duct on Calibration/Test Results Variations in Burner Air Turbulators Discovered.

Similar presentations


Presentation on theme: "Round Robin II Calibration/Test Results Impact of Burner Tab and Intake Duct on Calibration/Test Results Variations in Burner Air Turbulators Discovered."— Presentation transcript:

1 Round Robin II Calibration/Test Results Impact of Burner Tab and Intake Duct on Calibration/Test Results Variations in Burner Air Turbulators Discovered

2 Round Robin II Calibration Requirements Thermocouple Rake Temperatures: 1850+/- 100 o F Heat Flux: 16.0 +/- 0.8 Btu/ft 2 sec Air Intake Velocity: 2150 +/- 50 ft/min

3 Round Robin II Recommended Burner Configuration Igniters @ 10:00 Position 1 Tab in Top Left Position 3.75-Inch Distance from Nozzle Tip to Turbulator Static Disc In Draft Tube

4 Round Robin II Material Combinations: 1) 2 Layer 0.60 lb/ft 3 Fiberglass 2) 1 Layer Nextel Ceramic Paper/2 Layer 0.42 lb/ft 3 Fiberglass 3) 2 Layer 0.60 lb/ft 3 Curlon 4) 1 Layer TTI Felt/1 Layer 0.42 lb/ft 3 Fiberglass

5 FAATC Round Robin II Tab/Igniter Arrangement

6

7 Various Burner Arrangements Used in Round Robin II

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24 Influence of Tab and Intake Duct on Calibration and Test Results

25 Position of Flame Deflection Tab

26 No Tab/With Duct (NTWD) 4 Burner Configurations: With Tab/With Duct (WTWD) No Tab/No Duct (NTND) With Tab/No Duct (WTND)

27

28

29

30

31

32 Tab/Intake Duct Test Conclusions Burner Calibration Influenced More From Tab Than Duct Test Results Influenced More From Burner Set-up Than Calibration No Tab = Temp Calibration = Quicker Failure Time/

33 Influence of Turbulator on Calibration and Test Results

34 Differences Between “Old” and “New” Park Burners OldNew No Static DiscStatic Disc 2 3/4 -Inch Turbulator2 5/8 -Inch Turbulator Opposing Turbulator FlowIdentical Turbulator Flow

35 Old and New Style Turbulators OldNew 2 3/4 ” I.D.2 5/8 ” I.D. C.C.W. C.W. 4” O.D. 3 7/8 ” O.D. C.W. No Disc Disc

36 Burner Equipment Assortment

37 Monarch H215 Turbulator with Static Disc

38

39