Download presentation
Presentation is loading. Please wait.
Published byLogan Hickey Modified over 11 years ago
1
The author has a financial interest in the matter under presentation Dr. Rupal Shah, New Vision Laser Centers, India
2
Uses only the femtosecond laser for completing the entire LASIK procedure No need for an excimer laser Possible only with the VisuMax Laser from Carl Zeiss Two Procedures FLEx=Femtosecond Lenticule Extraction SMILE=Small Incision Lenticule Extraction
3
All-Femto Lasik Integrated Solution Benefits and Advantages Advantages for the patient Vision correction w/o corneal ablation Result quality independent of external conditions High refractive correction with less induced aberration Fast single-step treatment Short period of stress and fear No need to change stations Potential for minimal-invasive procedure Better and faster healing (small incisions) Preserved biomechanical stability of the cornea Potential for correction of higher myopes Lower incidence of Dry-Eye syndrome (to be proven) Advantages for the surgeon Differentiation from other LVC providers Uniqueness of AIO procedure (marketing, positioning) Workflow improvements Fast bilateral treatment w/o need to change to excimer higher patient throughput Less space requirement Increased profitability Premium procedure provides higher margin potential (ex.: Intralase, Wavefront) Minimal-invasive treatment may increase demand Only one laser, with the investment, consumables and service costs for only laser
4
683 eyes treated between Aug 2008 and February 2010 Includes eyes treated with both FLEx and SMILE All consecutive eyes- All eyes treated have been included Video Illustrates technique of All in One (AiO) Femtosecond Laser Refractive Surgery
5
Subject Demographics MeanRange Age25 y18 y to 50y MR SEQ-4.56 D ± 2.04 D-0.75 D to -10.38 D MR Sphere-4.22 D ± 1.95 D-0.50 D to -10.00 D MR Cylinder-0.68 D ± 0.72 Dup to -4.50 D Pre-operative: 683 eligible eyes (339 OD, 344 OS) 429 female eyes, 254 male eyes
6
Postoperative Results MeanRange MR SEQ0.00 D ± 0.26 D1.00 D to -1.25 D MR Sphere0.00 D ± 0.21 D1.00 D to -1.25 D MR Cylinder-0.10 D ± 0.26 Dup to -1.75 D 6 month423 eyes
7
AiO Safety Change in CDVA @3 month 92% unchanged/gained
8
AiO Stability Achieved correction (MR SEQ) over time Highly stable refraction over time!
9
AiO Refractive Outcome MR SEQ Percent within Attempted @1w and @6m 1 week (639) 6 month (423) High predictability for early and late follow-ups!
10
AiO Refractive Outcome MR SEQ Percent within Attempted @1w 99% ± 1.00 D @3m 100% ± 1.00 D
11
Only 94% are 20/25 or better preOP
12
AiO-Astigmatism Correction Normalized Double Angle Minus Cylinder – Scatter Plot only eyes with myopic astigmatism preOP (485 eyes with myopic astigmatism) High predictability in cylinder correction after 1 week! 1 week (460 eyes with myopic astigmatism)