An assessment of the feasibility and effectiveness of a method of performing cardiopulmonary resuscitation during microgravity. Simon N Evetts, Lisa M Evetts, T Russomano, J Castro and J Ernsting CB OBE. Microgravity Laboratory, PUCRS, Porto Alegre, Brazil. Human Physiology and Aerospace Medicine Group, King’s College London.
2
Background CPR in microgravity. Current procedures –Restrained. –Unrestrained. Need for effective unaided, single person CPR in space.
3
Recent and current CPR guidelines European Resuscitation Council 1998: – Mouth-to-mouth ventilation requiring tidal volumes of 400 – 500 ml. – Chest compression depth of 40 – 50 mm. –Chest compression rate of ~ 100 compressions.min -1. European Resuscitation Council 2001: –Tidal volumes of 700 – 1000 ml. –Chest compression depth of 40 – 50 mm. –Chest compression rate in excess of 100 min -1.
4
Evetts, Russomano, Castro CPR Method. Human subject in microgravity (position only).
5
ERC Method. Human subject in microgravity (position only).
6
ERC Method. Manikin use in microgravity (position and CPR).
7
Study Method Subjects/investigators. Laerdal CPR Manikin adaptation. Pre & post flight procedures. In flight procedures. Measurements.
8
Results Measure+1G Z Microgravity Chest Compressions Depth (mm)43.6 ± 0.5941.3 ± 1.03 Range (min-max, mm)40.4 – 47.127.6 – 51.2 Rate (compressions.min -1 )97.1 ± 3.080.2 ± 3.4 Percent correct (depth)90%60% n225672 Volume Volume (ml)507.6 ± 11.5491 ± 50.4 Range (min-max, ml)423 – 570284 - 891 Percent correct87%69% n3032
9
Results Measure+1G Z Microgravity Chest Compressions Depth (mm)43.6 ± 0.5941.3 ± 1.03 Range (min-max, mm)40.4 – 47.127.6 – 51.2 Rate (compressions.min -1 )97.1 ± 3.080.2 ± 3.4 Percent correct (depth)90%60% n225672 Volume Volume (ml)507.6 ± 11.5491 ± 50.4 Range (min-max, ml)423 – 570284 - 891 Percent correct87%69% n3032
10
Results Measure+1G Z Microgravity Chest Compressions Depth (mm)43.6 ± 0.5941.3 ± 1.03 Range (min-max, mm)40.4 – 47.127.6 – 51.2 Rate (compressions.min -1 )97.1 ± 3.0 *80.2 ± 3.4 * Percent correct (depth)90%60% n225672 Volume Volume (ml)507.6 ± 11.5491 ± 50.4 Range (min-max, ml)423 – 570284 - 891 Percent correct87%69% n3032 * P < 0.05
11
Results Measure+1G Z Microgravity Chest Compressions Depth (mm)43.6 ± 0.5941.3 ± 1.03 Range (min-max, mm)40.4 – 47.127.6 – 51.2 Rate (compressions.min -1 )97.1 ± 3.0 *80.2 ± 3.4 * Percent correct (depth)90%60% n225672 Volume Volume (ml)507.6 ± 11.5491 ± 50.4 Range (min-max, ml)423 – 570284 - 891 Percent correct87%69% n3032
12
Discussion Reasons for insufficient rate of chest compression and greater variation of measures in microgravity. – Novelty of environment. – Variable acceleration forces. – Shortness of microgravity exposure. – Degree of manikin reliability.
13
ERC compared to other methods of performing CPR in microgravity. Current unpublished findings. Further research required: – Effects of training and expertise. – Effects of strength. – Effects of anthropometric indices. Discussion
14
Effectiveness of the ERC method for all populations will need to be ascertained before it can be considered a viable method. CPR of this nature is more difficult than at +1G Z and will therefore require appropriate pre-mission training. Preliminary results indicate that the ERC method of unaided, single person CPR in microgravity is likely to be viable for use in space. Conclusion