Basic Refrigeration, Its Components, and Its Cycle
Mingledorff’s, Inc. Basic Refrigeration, Its Components, and Its Cycle
2
Introduction to Refrigeration
Refrigeration: Cooling to preserve products and provide comfort. Types of Refrigeration Processes High Temperature - Air conditioning (comfort cooling) Medium Temperature - Food preservation (keeping product cool) Low Temperature - Food preservation (freezing of the product)
3
What is Refrigeration? Remember: Heat flows from warm to cold.
The process of transferring heat from a place where it is not wanted to a place where it makes little or no difference. Remember: Heat flows from warm to cold.
4
One ton of Air Conditioning = The removal of 12,000 Btu per hour.
How Do We Rate Air Conditioning Equipment? One ton of Air Conditioning = The removal of 12,000 Btu per hour.
5
Four Major Refrigeration System Components
The evaporator The compressor The condenser The metering device
6
The Four Major Components
7
The Evaporator A heat exchanger to absorb heat
Evaporator coil - used to absorb heat from the conditioned space or product Located on the low side of the sealed system between the metering device and low side of the compressor
8
The Evaporator Operates at temperatures colder than the medium passing across the coil Absorbs heat by boiling a low temperature liquid to a low temperature vapor Metering device feeds liquid refrigerant into the evaporator. Under standard conditions, the mixture coming into the evaporator is 75% liquid and 25% vapor
9
The Evaporator Superheat - the heating of a vapor above the refrigerant saturation temperature Superheat ensures that no liquid returns to the compressor Design evaporator superheat ranges from 8 to 12 degrees F Superheat is determined by subtracting the evaporator's saturation temperature from the temperature of the outlet of the evaporator
10
The Evaporator
11
The Compressor Pumps heat laden vapor from the evaporator to the condenser The compressor reduces the pressure on the low side of the system The compressor increases the pressure on the high side of the system
12
The Compressor Most common types of compressors used are the reciprocating, the rotary, and the scroll Positive displacement compressors require that the compressed gas be moved into the condenser or damage will occur
13
The Compressor
14
The Compressor
15
The Condenser Rejects sensible and latent heat from the system that was absorbed by the evaporator and the compressor Located on the high side of system
16
The Condenser The heat is released from the refrigerant in the condenser causing it to change state from a high-temperature, high-pressure vapor to a high-pressure high-temperature liquid Condensing temperature is determined by the system's head pressure
17
The Condenser The condenser normally subcools the liquid at the end of the condenser Subcooling is lowering the temperature of a liquid below saturation Standard air cooled condensers are designed to subcool the liquid by a minimum of 10 degrees F below the saturation temperature Amount of subcooling is determined by subtracting the outlet temperature of the condenser from the condenser saturation temperature
18
The Condenser
19
The Refrigerant Metering Device
Controls the flow of subcooled liquid refrigerant into the evaporator Orifice Metering Device-Creates a pressure drop between the high side and low side of the sealed system 25% of the liquid leaving the metering device turns to vapor called flash gas
20
The Refrigerant Metering Device
21
The Refrigerant Metering Device
22
Low Side/High Side
23
The Refrigeration System
COMPRESSOR LOW PRESSURE VAPOR LOW PRESSURE LIQUID HIGH PRESSURE LIQUID HIGH PRESSURE VAPOR LIQUID REFRIGERANT RECEIVER EVAPORATOR CONDENSER TX VALVE ACCUMULATOR OIL SEPARATOR DRIER SOLENOID SIGHT GLASS
24
Now, Lets Play Lets Put What We Have Learned and Apply It To The Refrigeration Trainer