Presentation is loading. Please wait.

Presentation is loading. Please wait.

GODAE Quality Control Pilot Project Status Report - June, 2008 Final IGST Meeting Washington, D.C. James Cummings Naval Research Laboratory Outline 1.Data.

Similar presentations


Presentation on theme: "GODAE Quality Control Pilot Project Status Report - June, 2008 Final IGST Meeting Washington, D.C. James Cummings Naval Research Laboratory Outline 1.Data."— Presentation transcript:

1 GODAE Quality Control Pilot Project Status Report - June, 2008 Final IGST Meeting Washington, D.C. James Cummings Naval Research Laboratory Outline 1.Data Sources 2.Output File Structure and Reference Data 3.Plans and Issues

2 UKMO –January 2003 to present, real-time push to USGODAE server BMRC –2005 and 2006 only, one time only push to USGODAE server MEDS –June 2004 to present, real-time push to USGODAE server Coriolis –January 2004 to present, pull to USGODAE server: /ifremer/coriolis/mercator at ftp.ifremer.fr –CO_BA, CO_CT, CO_MO, CO_PF, CO_TE, CO_XB FNMOC –March 2003 to present, real-time push to USGODAE server GODAE QC Pilot Project: Data Providers

3 QC results from centers separated by call sign –profile match ups based on call sign, location and observation time –database contains observed values and supplemental information to understand QC decisions –provides history of real-time QC decisions made on a platform over the lifetime of the platform call sign database format is NetCDF –based on Coriolis multiple profile NetCDF file structure –easily expanded with new QC variables or new data providers –sorted by observation time and then data center for ease of use starting point for follow-on analysis and intercomparison of QC outcomes GODAE QC Pilot Project: Call Sign Databases

4 FNMOCMEDSCoriolisUKMO GODAE QC Application Program Interface (API) read various QC data formats, check for valid call sign, match profiles (lat, lon, time, call sign), populate database structure with observation, QC codes, QC flags, and supplemental information, resolve QC conflicts, sort by observation time, update NetCDF call sign database 1900305.nc Argo Float A8ES9.nc Ship XBT 52007.nc TAO Mooring Call Sign NetCDF Databases BMRC

5 dacsource of data (FNMOC, MEDS, Coriolis, UKMO, BMRC) dtgobservation time dtg_qcquality observation time lat, lonobservation position pos_qcquality observation position n_lvlnumber levels lvlobservation depth levels salobserved salinity sal_clmsalinity climatology sal_fcstsalinity forecast sal_flgsalinity QC test failures sal_qcsalinity profile quality GODAE QC Pilot Project: Database Variables sal_qc_lvlsalinity level quality tmpobserved temperature tmp_clmtemperature climatology tmp_fcsttemperature forecast tmp_flgtemperature QC test failures tmp_qctemperature profile quality tmp_qc_lvltemperature level quality signcall sign signobservation call sign upd_dtgprofile update time at center qcprofile QC outcomes differ qc_lvllevel QC outcomes differ ndxindex to other DAC profiles

6 Analysis/Forecast backgrounds UKMO: FOAM forecast profile FNMOC: NCODA analysis profile (persistence forecast) Climatology FNMOC: Navy GDEM temperature and salinity climatology BMRC: WOA or CARS temperature and salinity climatology QC Conflict Variables – entire profile and level-by-level –simple scheme to indicate differences of QC outcomes among centers 0 – profile (level) accepted (or rejected) by all centers 1 – profile (level) temperature QC outcomes differ 2 – profile (level) salinity QC outcomes differ 3 – profile (level) temperature and salinity QC outcomes differ GODAE QC Pilot Project: Reference Data

7 Plans: initialize call sign databases with 2003-2008 production run –missing complete set of BMRC QC data files – Gary? –host call sign data files on USGODAE server –install GODAE_QC_API on USGODAE server –update call sign data base files in near real-time (daily, weekly?) Issues (1): US GODAE server hardware upgrade –GODAE_QC_API cannot run on existing hardware –still waiting on server hardware upgrade funded by ONR Issues (2) :Data problems –BMRC and Coriolis data are NetCDF – problems with corrupted data (bad values); have to work through data problems one file at a time –data corruption problems slowing down 2003-2008 production run –FNMOC, UKMO, MEDS files are Fortran readable – no data corruption problems with these files GODAE QC Pilot Project: Plans and Issues

8 END


Download ppt "GODAE Quality Control Pilot Project Status Report - June, 2008 Final IGST Meeting Washington, D.C. James Cummings Naval Research Laboratory Outline 1.Data."

Similar presentations


Ads by Google