www.hoarelea.com Wind Farm Noise Impact Assessment NOISE PREDICTIONS – SOURCE DATA AND PROPAGATION
2
www.hoarelea.com Source Propagation Receiver The situation to be assessed ….
3
www.hoarelea.com VHVH V 10 SWL v = SPL v + 10 x log ( 4 x p x r 2 ) – 6dB Source Sound Power (IEC 61400-11) r H
4
www.hoarelea.com ISO 61400-11: Frequency based data Third octave SWL Narrow band tonal assessment
5
www.hoarelea.com Sound power values? Tested sound power (IEC 61400-11) with reported test uncertainty σ Warranted values: includes “safety margin” of typically up to 2dB(A) …… but sometimes not (commercial considerations) Turbine specification: additional uncertainty in warranty? Declared values: procedure of IEC 61400-14 for adding uncertainties (1.654 σ) N.B: test results are L Aeq data, so L A90 prediction is obtained by subtraction of 2dB
6
www.hoarelea.com Source Propagation Receiver The situation to be assessed ….
7
www.hoarelea.com Propagation models ‘Exact’ numerical methods (e.g. parabolic equation, fast field program) Approximate semi-analytical methods (e.g. ray tracing) Empirical ‘engineering’ methods (e.g. ISO 9613-2, Concawe) Input data Calculation implementation Output results
8
www.hoarelea.com Factors affecting sound propagation
9
www.hoarelea.com Factors affecting sound propagation - 1 Spherical spreading of noise Atmospheric attenuation
10
www.hoarelea.com Factors affecting sound propagation - 1
11
www.hoarelea.com Factors affecting sound propagation - 1
12
www.hoarelea.com Factors affecting sound propagation - 2
13
www.hoarelea.com Factors affecting sound propagation - 2 In ISO 9613-2: modelled by ground factor coefficient G (0 to 1)
14
www.hoarelea.com Factors affecting sound propagation - 2 G = 1 : soft, porous ground ground covered by grass or trees cultivated farming land Not used as it will often under-predict G= 0: hard ground paving, water ice, concrete, etc. Industrial ground Robust but can over-predict, particularly with warranted source data G= 0.5: mixed ground Used with warranted source data or tested data + uncertainty
15
www.hoarelea.com Factors affecting sound propagation - 3 Refraction effects…
16
www.hoarelea.com Factors affecting sound propagation - 3 Hot Cold Temperature lapse Upwind
17
www.hoarelea.com Factors affecting sound propagation - 3 Hot Cold Temperature inversion Downwind
18
www.hoarelea.com Factors affecting sound propagation - 4
19
www.hoarelea.com Factors affecting sound propagation - 4 Sound energy enters ‘shadow region’ via turbulent scattering
20
www.hoarelea.com Factors affecting sound propagation – 3 + 4
21
www.hoarelea.com Comparison of PE and ISO 9613 results 20m 200m 1000m Harmonoise PE model (based on annual measured meteorological conditions [Salomons]) ISO 9613 (based on typical downwind propagation conditions) Percentage of time below stated noise level, % Calculated noise level, dB
22
www.hoarelea.com Factors affecting sound propagation - 6
23
www.hoarelea.com Factors affecting sound propagation - 6 In downwind conditions: limited to no more than 2 to 3 dB Terrain = noise barrier?
24
www.hoarelea.com Factors affecting sound propagation - 6 “Valley effect”: +3 dB h m ≥1.5 abs(h s -h r )/2
25
www.hoarelea.com Measurement studies 3 Separate wind farm sites, both located in rural environments and each comprising more than 20 turbines Two-speed turbines rated at over 2MW peak generating capacity, 60 to 70m hub height Type 1 sound meters continuously sampling statistical and equivalent data at varying distances, with double wind-shield arrangements Published 2007-2009
26
www.hoarelea.com Measurement locations: from approximately 100m to 750 m from nearest turbine Very flat terrain Minimal vegetation Propagation path covered by peat bog Ground prone to flooding – saturated for duration of survey Wind Farm Envelope N Site B
27
www.hoarelea.com Site B Single site wind speed (G = 0 / 754m)
28
www.hoarelea.com Turbine specific wind speed (G = 0 / 754m) Site B
29
www.hoarelea.com Turbine specific wind speed (G = 0 / 754m) Site B
30
www.hoarelea.com Turbine specific wind speed (G = 0 / 754m) Site B
31
www.hoarelea.com Turbine specific wind speed (G = 0 / 754m) +2dB(A) “warranty” margin added ~5dB Site B
32
www.hoarelea.com Main measurement locations: from approximately 100m to 820 m from nearest turbine Lightly undulating but acoustically flat terrain Minimal vegetation surrounding turbines, forestry close to locations Ground cover of mixed soft ground and flooded areas N Wind Farm Envelope P1 P2 P3 P4 P5 Predictions are made for: high speed mode only G=0.5 tested sound power data + 1dB (Stated test uncertainty) Site C
33
www.hoarelea.com Location P4: 700 m distance Turbine only (predicted) Turbine + background Site C
34
www.hoarelea.com Additional research Evans and Cooper Comparison of predicted and measured wind farm noise levels and implications for assessments of new wind farms Paper Number 30, Proceedings of ACOUSTICS 2011 2-4 November 2011, Gold Coast, Australia “Steady slope”“Concave”
35
www.hoarelea.com Recommendations For use and application of ISO 9613-2 to WTN L A90 = L Aeq – 2 dB Use spectrum data if available 4m receiver height 10 degrees / 70% humidity Do not use G=1 G=0.5 recommended, with source levels which incorporate test uncertainties (as in most warranties or “declared“ values as per IEC 61400-14) For propagation across a valley add +3dB Terrain screening: no more than -2dB State all assumption and input data
36
www.hoarelea.com Thank you