A Mechanism for Data Quality Estimation of On-Body Cardiac Sensor Networks Sunghoon Ivan Lee * Charles Ling * Ani Nahapetian *† Majid Sarrafzadeh * *Computer Science, UCLA †Computer Science, CSUN Copyright: UCLA Wireless Health Institute
2
Wireless Health Institute (WHI) - UCLA Campus Community – School of Medicine – Medical Center – School of Engineering – School of Nursing – School of Public Health – College of Letters & Science – Anderson School of Management Unique approach – End-to-end integration from sensing to medical informatics to call center – Develop and verify new healthcare methods and services – Establish standards for efficacy, reliability, interoperability, and security
3
Cardiac-Monitoring Sensors BANs or PANs involve various types of wearable and non- invasive sensors on body – Cardiac Sensor, EMG, EEG, Glucose sensor, Motion sensor, etc. Cardiac monitoring sensors are the most common and widely used sensors – For example, in the survey on wearable sensor-based systems for health monitoring [17], 90% of the introduced systems involve cardiac monitoring sensors. Copyright: UCLA Wireless Health Institute3
4
Problems with Wearable Cardiac Sensors Sensors often suffer from high level of noise Types of possible noise include i.Channel noise produced by human body [11, 19] ii.Noise caused by environments [5] iii.Noise from loose physical contact of the sensor node to the human body Motion artifacts have the most significant degradation effect on the quality of sensor data, especially when the subject is highly mobile (e.g., at-home remote health care applications). 4
5
Motivation Example This signal was obtained from one of our participants wearing an on-body ECG sensor (Alive Heart Monitor [1]) at wrist. Copyright: UCLA Wireless Health Institute 5
6
Motivation Example Therefore, multiple sensors are often mounted at different parts of the body to provide higher data quality in a highly mobile environment. Copyright: UCLA Wireless Health Institute6
7
Data Quality Information For continuous and pervasive health monitoring environment, data quality information can be very useful – Automatically detecting sensors producing clean data In the field of medicine, extra manpower is required to manually filter out polluted data [20] – Improving continuous monitoring of patients – The data quality information can be also used to optimize the resources the pervasive system. This is a very important issue for pervasive systems Copyright: UCLA Wireless Health Institute7
8
Objective Our work introduces a mechanism for data quality estimation of a BAN composed of cardiac sensors specifically considering resource scarceness Copyright: UCLA Wireless Health Institute8
9
Considered BAN Structure The mechanism considers a BAN structure that all cardiac sensors transmit data to a single aggregator Copyright: UCLA Wireless Health Institute9 Sensor node #1 Sensor node #2 Aggregator Body Sensor Network
10
Summary of the Proposed Mechanism STEP 1: Local Data Quality Estimation Individual sensors filter out most of the normal events and recognize any abnormal events (motion artifact noise + health hazardous events) Copyright: UCLA Wireless Health Institute10 Sensor node #1 Sensor node #2 Aggregator Body Sensor Network
11
Summary of the Proposed Mechanism STEP 2: Global Data Quality Estimation Aggregates information about the local data quality and fuses the information to estimate the data quality of the overall BAN. Copyright: UCLA Wireless Health Institute11 Sensor node #1 Sensor node #2 Aggregator Body Sensor Network
12
Local Data Quality Estimation Detect any abnormal events in data generated from a single cardiac sensor This method is based on a well known fact that amplitude of cardiac signal and inter- pulse interval (IPI) variability are effect bedside measurements to detect any abnormal events [4], [8], [9]. Copyright: UCLA Wireless Health Institute12
13
The overview of the local data quality estimation Digital filters include [16] i.An integer coefficient band-pass filter ii.A derivative filter combined with an amplitude square process iii.Moving window integrator Peak detection logic locates cardiac cycles [18] Copyright: UCLA Wireless Health Institute13
14
The overview of the local data quality estimation Using the location of cardiac cycles, we extract the time length of each cardiac cycle (i.e., IPI) We define this high pass filtered IPI time series as IPI variation, and denote it as v[n] Copyright: UCLA Wireless Health Institute14
15
The overview of the local data quality estimation The time series of average amplitude of cardiac cycle is denoted as Copyright: UCLA Wireless Health Institute15
16
Irregular Fluctuation Now we have new time seriesand The proposed mechanism focuses on discarding most of normal cardiac cycles based on observing irregular fluctuation – Irregular fluctuation describes erratic movements in a time series that follow no recognizable or regular patter [5]. – Health hazardous events carry irregular fluctuation in and/or. [14] – Our observation verifies that motion artifact noise also carries irregular fluctuation in and/or Copyright: UCLA Wireless Health Institute16
17
Pattern of normal cycles We define the pattern of normal cycles as the degree of variation in normal v[n] and a[n] within a window size of N assuming Gaussian distribution – It is actually known that the distribution of normal cardiac cycles are usually skewed rather than Gaussian [12]. – However, these models are very complicated, and usually evolve over time. – Since our objective is to discard most of normal cardiac cycle rather than accurately model the distribution, Gaussian is a good approximation Copyright: UCLA Wireless Health Institute17
18
Pattern Learning Process The pattern learning process involves computing the mean and the std. dev. of normal cycles for a window size of N. – Learning process bounded by O(N). – It requires local memory to store N numbers. The proposed mechanism determines that the newest cardiac cycle of index n has high data quality if note that δ can be adaptively chosen as a result of the training process Copyright: UCLA Wireless Health Institute18
19
Local Data Quality Estimation The output of the local estimation, which is then transmitted to the aggregator is In our experiment, we asked participants to sit on a chair without any movements to acquire N=20 normal cycles. Then, δ is chosen such that all N normal cycles satisfy the above inequality. Copyright: UCLA Wireless Health Institute19 if otherwise
20
Global Data Quality Estimation The data fusion process is performed at the aggregator side. STEP 1: Temporal synchronization based on the minimum sampling rate for real-time purpose. (sensors may have different sampling rate) Copyright: UCLA Wireless Health Institute20 Synchronization t1[m]t1[m] t2[m]t2[m] t3[m]t3[m]
21
Global Data Quality Estimation Then, t k [m] is defined as t k [m] = Q k [n] for m within each cardiac cycle. (mathematical details provided in the paper) Intuitively, it is a time series for the k th sensor that shows the quality of a cardiac cycle in a synchronized sampling rate Copyright: UCLA Wireless Health Institute21
22
Global Data Quality Estimation STEP 2: we fuse the synchronized t k [m] to estimate the data quality t[m] of the overall BAN using a majority voting. Copyright: UCLA Wireless Health Institute22
23
Experimental & Simulation Results Experiment – Conducted on 4 participants to show that the proposed mechanism recognizes the noise created by motion artifacts. Simulation – Simulation on multi-variable cardiac data (from PhysioNet) to address that the mechanism can recognize the noise created by health hazardous events such as hearth arrhythmia. Copyright: UCLA Wireless Health Institute23
24
Experiment 4 Participants 3 off-the-shelf cardiac sensors (i.e., K = 3) – CHEST: Alive Heart Monitor – LEG: Vernier EKG Sensor – FINGER: Nonin Onyx 9560 SpO2 Sensors Copyright: UCLA Wireless Health Institute24
25
Experiment Set of actions that simulates the average daily activity of a person based on the American Time User Survey (ATUS) [21]. – Walking – Sitting down with no movement – Sitting down while moving upper limbs – Bending down to pick up an object – Standing up while moving upper limbs Participants performed the actions for 10 seconds and rest for another 10 seconds. Then, this combination of action and rest is repeated 3 times – clearly distinguishing the noise from normal signal We manually annotated all cardiac cycles to be either normal or abnormal (noise), and compared the detection results (i.e., t k [m] ) against this ground truth annotation for each sensor data. Copyright: UCLA Wireless Health Institute25
26
Illustrative Example of Experimental Results Copyright: UCLA Wireless Health Institute26
27
Experimental Results r d : the overall detection rate r fa : false abnormal rate r fn : false normal rate Copyright: UCLA Wireless Health Institute27 In average, the detection rate for the abnormal cycles can be detected at the rate of 90.56% when the data was fused. The false abnormal and false normal rates were 3.89% and 25.11%, respectively.
28
Simulation The database used in this simulation is the MGH/MF Waveform Database from PhysioNet [10]. – Due to the limitation and safety issues in recruiting participants with severe cardiac ailments who are likely to undergo a health hazardous cardiac problem during the experiment Includes – Three ECGs – An arterial pressure – A pulmonary arterial pressure – A central venous pressure signal. Copyright: UCLA Wireless Health Institute28
29
Simulation Two interesting observations 1.All local signals had the same IPI time series since none of the sensors is locally distorted due to motion artifacts. 2.The average ratio of the number of normal to abnormal cardiac cycles is 99.1%. We investigate detection rate for normal and abnormal cycles separately. Copyright: UCLA Wireless Health Institute29
30
Simulation Results Copyright: UCLA Wireless Health Institute30 In average, the detection rate for the abnormal cycles is 100% and the detection rate for the normal cycles is 87.8%. N’ a : # detected abnormal N a : # actual abnormal r fn : false normal rate N’ n : # detected normal N’ n : # actual normal r fa : false abnormal rate
31
Summary We introduced an efficient mechanism for estimating data quality of a BAN composed of cardiac sensors. – Low complexity The proposed method employs – Local data quality estimation – Global data quality estimation We presented experimental results based on three off-the-shelf cardiac sensor devices in order to detect motion artifact noise. We also presented simulation results to detect health hazardous events using the proposed mechanism. Copyright: UCLA Wireless Health Institute31
32
Thank you Questions? Please feel free to reach me at silee@cs.ucla.edu Copyright: UCLA Wireless Health Institute32