Presentation is loading. Please wait.

Presentation is loading. Please wait.

Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Similar presentations


Presentation on theme: "Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008."— Presentation transcript:

1 Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008

2 EIF FILTRES French compagny specialized since 30 years in filtration equipments and sampling treatments. January 30,2008 IFPAC 2008 – Baltimore January 29,2008

3 Our philosophy:  Leave the contaminants in process  Separate as fast as possible the contaminants from the sample  Reduce the treated volumes  Reduce and make easier the maintenance January 30,2008 IFPAC 2008 – Baltimore January 29,2008

4  Cross flow filtration with blow back systems  Liq/liq coalescing filter with jet fuel separator  Gas treament column  L Type housings  Modular and smart systems For that, we have developed : IFPAC 2008 – Baltimore January 29,2008

5 CROSS FLOW FILTRATION / BLOW BACK SYSTEMS IFPAC 2008 – Baltimore January 29,2008

6 High flow rate High contaminant amount Process Analyser Process Pipe IFPAC 2008 – Baltimore January 29,2008

7 High flow Process Analyser Process Pipe Traditional solutio n Filter 1 Large Coalescor filter 2 IFPAC 2008 – Baltimore January 29,2008

8 Low flow rate Process Analyser Process Pipe Alternative way Cross flow filter Small Coalescor Fast loop Fine filtration Small contaminant amount IFPAC 2008 – Baltimore January 29,2008 Low drain flow

9 Cross flow filters IFPAC 2008 – Baltimore January 29,2008

10 LIF – LIF GM – LIF - Mini with Sintered St/St element TAN - TAN GM with different kind of elements CROSS FLOW FILTERS IFPAC 2008 – Baltimore January 29,2008

11 MINI – CROSS FLOW FILTER  Low dead volume  Low flow fast loop IFPAC 2008 – Baltimore January 29,2008

12 Sizing reduction IFPAC 2008 – Baltimore January 29,2008

13 BLOW BACK SYSTEM IFPAC 2008 – Baltimore January 29,2008

14

15 Hydrophobic membrane Liquid / Liquid coalescor Coalescing Element IFPAC 2008 – Baltimore January 29,2008

16

17 NESSI  Global industry initiative, formed June 2000 to drive permanent change in how process Analytical is done  CPAC sponsorised ( Center of Process Analytical Industrial)  Modular, miniature & smart sample system technilogy  SP 76 standard  Micro analytical devices IntraFlow ™ IFPAC 2008 – Baltimore January 29,2008

18 This New technology Reduce the System Design Time Cut the Fabrication Expenses Improve the Analyzer Reliability Advance the Process Maintenance Easier IntraFlow ™ IFPAC 2008 – Baltimore January 29,2008

19 EIF Filtres Parker representative for French analytical market IntraFlow ™ IFPAC 2008 – Baltimore January 29,2008

20 IntraFlow ™ Parker IntraFlow ™ Patent Pending IntraFlow ™ IFPAC 2008 – Baltimore January 29,2008

21 Realisations IFPAC 2008 – Baltimore January 29,2008

22 Realisations IFPAC 2008 – Baltimore January 29,2008

23 COALESCING FILTER GAS EJECTOR SEPARATOR SPECIFIC ADAPTATOR FOR ROTAMETER BLOW BACK SYSTEM EIF TOPWORK COMPONENTS ISA/ANSI S 76.00.02 Compliant

24 Petrochemical application IFPAC 2008 – Baltimore January 29,2008

25 Typical gazoline sampling in front of Chromatograph IFPAC 2008 – Baltimore January 29,2008

26

27 Specifications :  Fluid : gazoline  Filtration needed  liquid-liquid coalescing needed IFPAC 2008 – Baltimore January 29,2008

28 New design in beginning of 2006  Cross flow filtration with blow back system  modular Intraflow assy  liquid-liquid coalescing with separator  Pneumatic control ( specific for the test) IFPAC 2008 – Baltimore January 29,2008

29 Gazoline sampling for sulphur analyzer IFPAC 2008 – Baltimore January 29,2008

30 TM Cross flow filtration Blow back system DECLIF HP MINI (low dead volume) To analyzer via Intra flow Fast loop Cross flow filter 2S2LIF GM MINI 2 microns (low dead volume) IFPAC 2008 – Baltimore January 29,2008

31 TM Gazoline treatment Séparator Coalescing housing IFPAC 2008 – Baltimore January 29,2008

32 first installations comments  Flow sheet needed  Free space needed around components with maintenance ( filters for example …)  How to install, vertically or horizontally  Drain and vent take into consideration IFPAC 2008 – Baltimore January 29,2008

33 The Answer !! IFPAC 2008 – Baltimore January 29,2008

34 3 D Solution IFPAC 2008 – Baltimore January 29,2008

35 The solution = 3D Patent Application Pending IFPAC 2008 – Baltimore January 29,2008

36 Video

37 The same sampling evolution IFPAC 2008 – Baltimore January 29,2008

38 TM  Compact  Top equipment easily accessible  Low dead volume Fast loop Astute SCF with tangential element 0,5 microns IFPAC 2008 – Baltimore January 29,2008

39 ASTUTE :  SP 76 compliant  Integrated cross flow filter  Modular  Compact  Low dead volume  Upgradeable IFPAC 2008 – Baltimore January 29,2008

40 ASTUTE :  Top equipment easily accessible  Vertical and horizontal position installation possible  On the fast loop or in derivation  All the different paths on the same module( sample, standard, drain, vent..) IFPAC 2008 – Baltimore January 29,2008

41 For the sampling:  Reduce or eliminate the sampling line  Decrease the response time  Reduce the product and drain volumes  Temperature control and heating easier  Reduce the sample contamination risk IFPAC 2008 – Baltimore January 29,2008

42 ASTUTE contribute to :  Measurement quality improvement  Cost of build and operating cost reduction  Maintenance easier  Installations sécurity improvement IFPAC 2008 – Baltimore January 29,2008

43 APPLICATIONS IFPAC 2008 – Baltimore January 29,2008

44 Moisture sensor Pressure regulator filter Flow meter IFPAC 2008 – Baltimore January 29,2008

45 TM ISOLATING VALVES PROCESS PIPE DIRECT CONNECTION ON PROCESS CCIMS CLAMPS CCIMS System IFPAC 2008 – Baltimore January 29,2008

46  Direct connection on process  Very short response time  Easy maintenance clamp connection  Low contamination level  Sampling reduction cost  No drain IFPAC 2008 – Baltimore January 29,2008