Excavation Lesson 3 M. S. Martin Sept 2009
2
De - Watering The removal of ground water and / or accumulated rainwater from within excavations or earthworks by means of mechanical pumps. Usually to enable continuation of work.
3
Typical Footings
9
Shoring
10
Shoring or Trench Support Manually or mechanically excavated trenches over 1.5m in depth require some form of support for the sides, to prevent possible collapse, while working in the trench. This is typically done by benching battering or ‘shoring’. Open or closed support systems are available in timber, steel or combinations of both.
11
Shoring – Add definition to P. 31 Trench support to sides of excavations to prevent possible collapse, typically trenches over 1.5m deep, must be benched, battered or ‘shored’.
12
Timber Shoring Bracket head of screw jack Waler Waling hook Plate head Poling boards Wedges Waling Cleat Strut Bevelled ends OPEN TIMBERING OPEN METAL SHEETING
13
Timber Shoring
15
Report if you see any of the following Next two slides from J. Bridges (SWSI) slides on shoring & trenching
16
Warning Signs If you notice any of the following situations, take remedial action and/or notify your supervisor immediately. Subsidence alongside trench Water entering trench
17
Warning Signs - Cont’d Earth Fretting from sides Tension Cracks Deflection in Shoring Excessive creaking in shoring
18
Surface & Sub-Surface Drainage: P. 20 It is a mandatory Local Council requirement to prevent surface eroded surface materials ending up in the street gutters and storm water pits/drains These fences may be constructed of –Polypropylene (shade cloth) –Straw bales –Geotech fabrics, etc. Geotextile filter fabric 3000 max. Drainage area 0.6ha. max Slope gradient 1:2 max. Slope length 60m max. DISTURBED AREA UN-DISTURBED AREA Posts driven 0.6 into ground SEDIMENT FENCE 600mm 200mm
20
Types of Drainage Surface Drains Dish Drains Rubble Drains Sub-surface drains
22
Cut & Fill Sites – P. 21 these types of sites need to have sufficient consideration to ensure adequate site drainage, and will typically use all of the drainage types mentioned above.
23
Slabs Types: –Slab on ground, basic garage, paths –Raft Slab –Waffle slab –Stiffened Raft –Any others ?
24
Stiffened Raft
25
Waffle Slab
26
Slab Calc’s
28
Volume Slab Break the slab into two areas, i.e. the slab and the thickened splayed edge beam. Firstly, calculate the volume of the slab; L x W x T =7.5x3.8x0.1 =2.850m³
29
Volume Beam The simplest way of calculating the beam is to calculate the average area of the beam section and multiply it by the centre line length of the beam L x W 0.350 x 0.100 = 0.035m² Now calculate the centre line length of the beam
30
Beam Length Now multiply the average beam area by the average length to calculate the volume of the beam; Area x Length 0.035x21.200 0.742m³
31
Totals To calculate the total volume of concrete in the slab and the beam, add the two separate volumes together; Volume of slab + Volume of beam 2.850+0.742 = 3.592m³ ORDER - 3.6m³ of concrete