Presentation is loading. Please wait.

Presentation is loading. Please wait.

DLX computer Electronic Computers M.

Similar presentations


Presentation on theme: "DLX computer Electronic Computers M."— Presentation transcript:

1 DLX computer Electronic Computers M

2 RISC architectures RISC vs CISC (Reduced Instruction Set Computer vs Complex Instruction Set Computer In CISC architectures the 10% of the instructions are used in 90% of cases Waste of silicium Bottleneck: the bus Mid ‘80s a new architecture: RISC Solution: reduction of instruction number and complexity (fewer simpler machine instructions) Fixed instruction format (simpler instruction decoders) Simpler control logic network increasing the number of on-chip registers Reduction of bus/memory accesses Increase of machine instructions needed for a job which is (in many cases) more than compensated (in term of time) by the reduction of bus accesses CISC and RISC are each one the best solution in different application fields Nowadays coexistence of both architectures in the same processor: analysis at the end of the course A simplified RISC architecture: DLX (implemented as real processor in the ‘80s as R4000)

3 DLX (fixed) instruction format
6 bit 5 bit 5 bit 5 bit 11 bit R Op-code RS1 RS2 Rd Cod. op (11 bit) extension Arithmetic or logic instructions as Rd  RS1 op RS2 or Set Conditions between registers I Op-code RS1 RS2 16 bit immediate operand Load, Store, conditional Branch , JR and JALR (Control transfer via register), Set Condition e ALU with immediate operator. In LD and ALU instructions RS2=destination, in the ST RS2=source. -- RS1 used as base address or as ALU value for the immediate instructions J Op-code 26 bit (PC relative) offset Direct and unconditional control transfer(J e JAL)

4 DLX non floating-point instructions
(31x32bit registers R31…R1 - R0=0 fixed - Ra and Rb any of the 32 registers) Data Transfer LW Ra, offset(Rb) LB Ra, offset(Rb) LBU Ra, offset(Rb) LHU Ra, offset(Rb) LH Ra, offset(Rb) SW Ra, offset(Rb) SH Ra, offset(Rb) SB Ra, offset(Rb) LHI Ra, value Arithmetic/Logic ADD Ra,Rb,Rc ADDI Ra,Rb,value ADDU Ra,Rb,Rc ADDUI Ra,Rb, value SUB Ra,Rb,Rc SUBI Ra,Rb,value SUBU Ra,Rb,Rc SUBUI Ra,Rb, value DIV Ra,Rb,Rc DIVI Ra,Rb,value MULU Ra,Rb,Rc MULI Ra,Rb, value SLL Ra ,Rb,Rc SLLI Ra,Rb;value SHR Ra,Rb.Rc SHRI Ra,Rb,value SLA Ra,Rb,Rc SLAI Ra,Rb,value OR Ra,Rb,Rc ORI Ra,Rb,value XOR Ra,Rb,Rc XORI Ra,Rb,value AND Ra,Rb,Rc ANDI Ra,Rb,value Control SETx Ra,Rb,Rc SETIx Ra,Rb,value BEQZ Ra, offset BNEQZ Ra, offset J offset JR Ra JL offset JLR Ra N.B. x can be LT, GT, LE, GE, EQ, NE JLx-> Jump and link saving PC in R31 Offset is a value within the instruction Postfix I means «immediate» (value within the instruction) PostfixA means «arithmetic» (sign extension) Postfix U means «unsigned» Postfix «x» is the ste condition Value is the immediate within the instruction

5 DLX ALU operations ALU is a combinatorial circuit !!!
S1 , S2 => ALU inputs (32 bit) S1 + S2 S1 – S2 S1 and S2 S1 or S2 S1 exor S2 Left Shift S1 of S2 positions Right Shift S1 of S2 positions Arithmetic Right Shift S1 of S2 positions S1 S2 1 Output Flags Zero Negative sign ALU is a combinatorial circuit !!!

6 Abstract instruction execution
Ready ? INSTR <= M [PC] INSTRUCTION FETCH INSTRUCTION DECODE* PC <= PC +4 A <= RS1 B <= RS2 Data transfer ALU Set Jump Branch A and B two internal registers unknown to the programmer

7 Example: LB (LOAD BYTE format I)
INSTR < M [PC] Op-code RS1 RS2 16 bit immediate operand PC < PC +4 A < RS1 B < RS2 LB Ra, offset(Rb) LOAD Address < A + (Instr15)16 ## Instr15..0 (A) = (RS1) Instr15.0. is the instruction offset Address 32 bit 31 MBbit LSbit Sign extension Dest. Reg. < (M[Addr]7)24 ## M[Addr]7..0 (Dest. Reg. = RS2) Sign extension !! Example M[Addr]7..0=A7H => ( )b Dest.REG <= FFFFFFA7H ## => JOIN operator Next Instruction Memory byte

8 Sign extension From the Control Unit IR 15 31 31 30…………17 16 15-0
(IR15)16 ## IR15..0 From the Control Unit IR 15 31 31 30…………17 16 15-0 BUS S1 o S0

9 Data transfer Instructions (R format) Examples
Addr. <- A + (Instr15)16 ## Instr15..0 A unsigned Data transfer Instructions (R format) Examples M[Addr]<=B SW LB Dest. <(M[Addr]7)24 ## M[Addr]7..0 LH Dest. < (M[Addr]15)16 ## M[Addr]15..0 Signed LBU Dest. < (0)24 ## M[Addr]7..0 . LHU LW Dest. <(0)16 ## M[Addr]15..0 Unsigned LW Ra, offset(Rb) LB Ra, offset(Rb) LBU Ra, offset(Rb) LHU Ra, offset(Rb) SW Ra, offset(Rb)

10 Register (format R) Immediate (format I) T<= B T<= (Instr15)16 ## Instr15..0 Register content signed if arithmetic operations ALUinstructions examples (I format) (T is a temporary hidden register unknown to the programmer) Dest <= A + T Dest <= A xor T Dest <= A = T Dest <= A and T Dest <= A or T ADD AND SUB XOR OR ADD Ra,Rb,Rc ADDI Ra,Rb,value ADDU Ra,Rb,Rc ADDUI Ra,Rb, value ……………………… The same scheme for the shift etc. A and B generic registers (RS1, RS2)

11 Register (format R) Immediate (format I) T<= B T<= (Instr15)16 ## Instr15..0 SET instructions (see branch) ex. SLT R1,R2,R3 Set R1=1 if R2 is less than R3 Dest=1 if A = T SEQ SLT SGE SNE SGT SLE Dest=1 if A < T Dest=1 if A >= T Dest=1 A <= T Dest=1 A > T Dest=1 if A! = T Register content as signed

12 JUMP Instructions JAL JALR JR JMP JAL JALR JAL JALR T <= PC
For saving PC in R31 T <= PC JALR JAL T <= PC JR JALR JMP JAL PC <= PC + (Instr25)6 ## Instr25..0 PC <= A format I format J JUMP Instructions J offset JR Ra JL offset JLR Ra JALR JAL R31 <= T

13 Branch Instructions A = 0 A! = 0 Ex. BNEQZ R5, 100
BEQZ BNEZ A = 0 A! = 0 YES YES NO NO Ex. BNEQZ R5, 100 Jump to PC+100 if R5 not equal 0 PC <= PC + (Instr15)16 ## Instr15..0 INIT

14 The Pipelining Principle
Pipelining is the main basic technique used for “speeding-up” a CPU. The key idea for pipelining is general, and is currently applied to several industry fields (productions lines, oil pipelines, …) A system S must execute N times a task A: A1 , A2 , A3 …AN S R1 , R2 , R3 …RN Latency : time occurring between the beginning and the end of task A (TA ). Throughput : frequency of each task completion

15 The Pipelining Principle
1) Sequential System A1 A2 A3 AN t TA Latency (execution time of a single instruction) = TA 2) Pipelined System (instruction are subdivided in stages – each stage during one nth – 4 in this example - of the entire instruction) – Instructions overlap S A P1 P2 P3 P4 t S1 S2 S3 S4 Si: pipeline stage

16 The Pipelining Principle
TP A1 P1 P2 P3 P4 TP : pipeline cycle Each cycle one instruction terminates P1 A2 P2 P3 P4 P1 A3 P2 P3 P4 P1 A4 P2 P3 P4 t An S S1 S2 S3 S4 L’intervallo di tempo Tp , detto cycle time della pipeline, costituisce la durata dell’intervallo elementare di funzionamento e determina il ritmo con cui le attività attraversano la pipeline: tutti gli stadi sono perfettamente sincronizzati in modo che allo scadere di ogni intervallo di funzionamento una attività viene completata, ed abbandona la pipeline, una nuova attività viene inserita nella pipeline e le altre attività presenti avanzano di uno stadio.

17 Instruction write-back Instruction execution
Instruction stages IF ID EX MEM WB Instruction fetch (from memory) Instruction write-back (if needed) Instruction decode Data memory access (if needed) Instruction execution (ALU)

18 Pipelining of a CPU (DLX)
Instruction sequence: I1 , I2 , I3 …IN Instruction j IF ID EX MEM WB t Combinatorial circuits IF/ID ID/EX EX/MEM MEM/WB IF ID EX MEM WB Registers (Pipeline D FF) CPU (datapath) Delay of the slowest stage Pipeline Cycle Clock Cycle CPI=1 (ideally !)

19 DLX Pipeline CPI (ideally) = 1 Tclk = Td + TP + Tsu Instr i Instr i+1
IF ID EX MEM WB CPI (ideally) = 1 Instr i IF ID EX MEM WB Instr i+1 Instr i+2 IF ID EX MEM WB IF ID EX MEM WB Instr i+3 IF ID EX MEM WB Instr i+4 Overhead introduced by the Pipeline Registers: Tclk = Td + TP + Tsu Clock Cycle Switch delay of the input stage register Delay of the slowest combinatorial stage Set-up time of the output stage register

20 Tp Delay of the slowest combinatorial stage Set-up time of the
Circuit Delay of the slowest combinatorial stage D Set-up time of the output stage register D Switch delay of the input stage register

21 Pipeline implementation requirements
Each stage is active at each clock cycle. The PC is incremented in the IF stage. PC Always 0 An ADDER should be introduced (PC <=PC+4) in the IF stage. But instructions are aligned then a 30 bit register (counter) is used, incremented by 1 each clock cycle Two Memory Data Registers are required (referred to as LMDR e SMDR). In fact when a LOAD is immediately followed by a STORE there is a WB/MEM stages overlap – two data waiting therefore to be written (one onto the memory, the other onto the RF). Each clock cycle 2 memory accesses must be possibly executed (IF, MEM): Instruction Memory (IM) and Data Memory (DM): “Harvard” Architecture The CPU clock is determined by the slowest stage: Pipeline Registers store both data and control information ( “distributed” control unit)

22 DLX Pipelined Datapath
Actually a programmable counter For Set Condition (also <0 and >0) [it acts on the output] IF ID EX MEM WB for Branch if jump For computing new PC value when branch JL and JLR (PC in R31) 4 A D M U X PC DEC =0? =0? INSTR MEM RF PC M U X RS1 A L U RS2 DATA MEM M U X RD M U X D I passi in cui viene suddivisa l’esecuzione di un’istruzione DLX sono quelli che abbiamo anticipato precedentemente: click , vengono giù. Come già anticipato, ogni passo Dell’esecuzione dell’istruzione viene eseguito da un’unità funzionale detta stadio click ed appaiono gli stadi; per consentire agli sia stadi di operarare simultaneamente su istruzioni diverse sia di scambiarsi informazioni fra gli stadi vengono inseriti dei registri, detti pipeline registers. Per semplicità pensiamo che siano dei registri edge-triggered che camponano sui fronti del clock della CPU, anche se è possibile utilizzare dei latch ed una diversa strategia di clocking. In un generico ciclo di clock ogni stadio elabora le informazioni presenti sul suo registro di ingresso, relative ad una data istruzione K e produce delle nuove informazioni, anch’esse relative all’istruzione K: all’inizio del ciclo successive queste informazioni vengono campionate sul regsitro d’uscita dello stadio, che è il regsistro d’ingresso dello stadio successivo: in questo modo lo stadio successivo esegue il passo che gli compete dell’istruzione K. Lo stadio su cui abbiamo focalizzato la nostra attenzione campionerà invece le informazioni provenienti dallo stadio a valle ed eseguirà il proprio passo sull’istruzione precedente (K-1). In sostanza, grazie ad i registri di pipeliene, in un dato ciclo ogni stadio lavora su informazioni relative ad un’istruzione diversa, e le istruzioni presenti nella pipeline avanzano di uno stadio ad ogni clock. L’uso dei pipeline regsister non è specifico del datapath dl DLX, ogni CPU in pipeline usa questi registri per trasportare le informazioni relative ad una sequenza di istruzioni attraverso gli stadi della pipeline. Vediamo invece ora come sono fatti gli stadi della pipeline del DLX. I primi due stadi sono indipendenti dal tipo di istruzione, mentre il tipo di elaborazione che viene eseguito nei 3 stadi successivi dipende dal tipo di istruszione. Ci limiteremo a 2 delle 3 istruzioni che abbiamo introdotto precedentemente: ALU e LOAD. Discuteremo successivamente il caso dei BRANCH. IF: Il PC fornisce l’indirizzo usato per accedere alla IM e prelevare l’istruzione: simultaneamente il PC viene incrementato al fine di ottenere l’indirizzo che sarà usato Per prelevare la prossima istruzione. Ignoriamo per ora la presenza del MUX. ID: l’istruzione prelevata nello stadio IF viene campionata su IF/ID e decodificata nello stadio ID: la rete di decodifica genera i segnali di controllo che vengono propagati verso tutti gli stadi attraverso i regsitri: in ID il decoder genera i segnali che verranno poi utilizzati nei vari stadi man mano che l’istruzione procede nella pipeline. Quasi tutte le istruzioni del DLX prevedono l’accesso in lettura ad uno o due registri: i campi dell’istruzione che specificano i registri da leggere occupano una posizione fissa nell’istruzione e nettamente separata dall’opcode: è possibile allora utilizzare questi campi per accedere ai regsitri e prelevare gli operandi dell’istruzione simultaneamente alla fase di decodifica: leggiamo gli operandi mentre siamo decodificando l’istruzione, senza sapere bene ancora cosa dovremo fare: poco male, se ci servirà un solo operando, o nessuno non li useremo, ma non ci costa nulla leggerli. I tre stadi successivi sono dipendenti dall’ istruzione: istruzione ALU: dobbiamo eseguire un’operazione logico/aritmetica sui registri letti in ID: i MUX selezioneranno come ingressi della ALU i valori dei registri provenienti dal regsitro ID/EX i segnali di controllo della ALU, provenienti dallo stadio precedente, selezioneranno l’operazione da eseguire: il risultato sarà pronto all’uscita della ALU alla fine del ciclio di clock e camponato sul regsitri EX/MEM all’inizio del clock successivo. Se l’istruzione è una LOAD, lo stadio EX è usato per calcolare l’indirizzo: ricordando che la modalità di indirizzamento è displacement, e che il registro che contiene la base dell’indirizzo è già stato letto in ID, quello che è necessario fare è abilitare la via in basso del MUX e come secondo operando abilitare il displacement: questo è contenuto nell’istruzione e viene estratto e cooertito a 32 bit nello stadio ID e passato allo stadio EX mediante il regsisto di pipeline ID/EX. Quindi dopo lo stadio EX il registro EX/MEM contiene il risultato dell’elaborazione, se è un’istruzione ALU, l’indirizzo se è una LOAD. MEM: se è una ALU, non bisogna accedere alla memoria: il risultato verrà semplicemente passato allo stadio WB attraverso il registro di pipeline MEM/WB. se è una LOAD, si accede alla memoria tramite l’indirizzo presente su EX/MEM ed il dato letto viene campionato poi sul registro MEM/WB. Stadio di WB: è attivo sia per una LOAD sia per un’istruzione di tipo ALU: in entrambi i casi bisogna scrivere sul Register File: nel primo caso il valore da scrivere è quello proveniente dalla data-memory, nel secondo caso è quello che è stato propagato dallo stadio EX: il MUX consente di selezionare fra i due valori quello che viene inviato sulla porta di scrittura del RF. L’identificatore del registro che deve essere scritto (campo Rd dell’istruzione) viene anch’esso dallo stadio WB, su cui è stato propagato da ID: difatti non possiamo usare il campo Rd dell’istruzione correntemente in ID Perché cosi’ facendo scriveremmo erroneamente sulla destinazione dell’istruzione correntemente in ID che non è qiuella di cui staimo seguendo l’evoluzione attraverso la pipeline ma bensi’ quella che la segue di 3 clock (è stata prelevata con 3 clock di ritardo) SE For operations with immediates Sign extension Number of dest. registers in case of LOAD and ALU instr. destination register number Data IF/ID ID/EX EX/MEM MEM/WB

23 ID stage (N.B. stage layout different from previous slide!)
IF/ID ID/EX IR (Jump; Jump and Link) 32 I R 26 (J and JL) IR (Offset/Immediate– Dest. reg. in R instr. ) LB IR31-26 (Opcode) SW DEC IR10-00 (R Istr.) Info travelling with the instruction IR25-21 RS1 A 32 P C 32 IR20-16 RS2 RF B DR 32 D Sign extension IR15 (31-16) Immed./Branch 16 IR25 SE (31-26) Jump 6 Sing extension PC (JL and JLR) 32 Data (from WB stage) Number of the dest. register (from WB stage)

24 DLX Pipelined Datapath
SMDR => Store Memory Data Register LMDR => Load memory data Register IRi => Instruction Register i for Set Condition (also <0 e >0) [it acts on output] IF ID for Branch EX MEM WB JL JLR (PC saved in R31) 4 A D M U X P C 1 P C 2 P C 3 P C 4 DEC C O N D =0? Address =0? PC M U X Data A A L U IM I R 1 RF L M D R X M U X B M U X DM S M D R I passi in cui viene suddivisa l’esecuzione di un’istruzione DLX sono quelli che abbiamo anticipato precedentemente: click , vengono giù. Come già anticipato, ogni passo Dell’esecuzione dell’istruzione viene eseguito da un’unità funzionale detta stadio click ed appaiono gli stadi; per consentire agli sia stadi di operarare simultaneamente su istruzioni diverse sia di scambiarsi informazioni fra gli stadi vengono inseriti dei registri, detti pipeline registers. Per semplicità pensiamo che siano dei registri edge-triggered che camponano sui fronti del clock della CPU, anche se è possibile utilizzare dei latch ed una diversa strategia di clocking. In un generico ciclo di clock ogni stadio elabora le informazioni presenti sul suo registro di ingresso, relative ad una data istruzione K e produce delle nuove informazioni, anch’esse relative all’istruzione K: all’inizio del ciclo successive queste informazioni vengono campionate sul regsitro d’uscita dello stadio, che è il regsistro d’ingresso dello stadio successivo: in questo modo lo stadio successivo esegue il passo che gli compete dell’istruzione K. Lo stadio su cui abbiamo focalizzato la nostra attenzione campionerà invece le informazioni provenienti dallo stadio a valle ed eseguirà il proprio passo sull’istruzione precedente (K-1). In sostanza, grazie ad i registri di pipeliene, in un dato ciclo ogni stadio lavora su informazioni relative ad un’istruzione diversa, e le istruzioni presenti nella pipeline avanzano di uno stadio ad ogni clock. L’uso dei pipeline regsister non è specifico del datapath dl DLX, ogni CPU in pipeline usa questi registri per trasportare le informazioni relative ad una sequenza di istruzioni attraverso gli stadi della pipeline. Vediamo invece ora come sono fatti gli stadi della pipeline del DLX. I primi due stadi sono indipendenti dal tipo di istruzione, mentre il tipo di elaborazione che viene eseguito nei 3 stadi successivi dipende dal tipo di istruszione. Ci limiteremo a 2 delle 3 istruzioni che abbiamo introdotto precedentemente: ALU e LOAD. Discuteremo successivamente il caso dei BRANCH. IF: Il PC fornisce l’indirizzo usato per accedere alla IM e prelevare l’istruzione: simultaneamente il PC viene incrementato al fine di ottenere l’indirizzo che sarà usato Per prelevare la prossima istruzione. Ignoriamo per ora la presenza del MUX. ID: l’istruzione prelevata nello stadio IF viene campionata su IF/ID e decodificata nello stadio ID: la rete di decodifica genera i segnali di controllo che vengono propagati verso tutti gli stadi attraverso i regsitri: in ID il decoder genera i segnali che verranno poi utilizzati nei vari stadi man mano che l’istruzione procede nella pipeline. Quasi tutte le istruzioni del DLX prevedono l’accesso in lettura ad uno o due registri: i campi dell’istruzione che specificano i registri da leggere occupano una posizione fissa nell’istruzione e nettamente separata dall’opcode: è possibile allora utilizzare questi campi per accedere ai regsitri e prelevare gli operandi dell’istruzione simultaneamente alla fase di decodifica: leggiamo gli operandi mentre siamo decodificando l’istruzione, senza sapere bene ancora cosa dovremo fare: poco male, se ci servirà un solo operando, o nessuno non li useremo, ma non ci costa nulla leggerli. I tre stadi successivi sono dipendenti dall’ istruzione: istruzione ALU: dobbiamo eseguire un’operazione logico/aritmetica sui registri letti in ID: i MUX selezioneranno come ingressi della ALU i valori dei registri provenienti dal regsitro ID/EX i segnali di controllo della ALU, provenienti dallo stadio precedente, selezioneranno l’operazione da eseguire: il risultato sarà pronto all’uscita della ALU alla fine del ciclio di clock e camponato sul regsitri EX/MEM all’inizio del clock successivo. Se l’istruzione è una LOAD, lo stadio EX è usato per calcolare l’indirizzo: ricordando che la modalità di indirizzamento è displacement, e che il registro che contiene la base dell’indirizzo è già stato letto in ID, quello che è necessario fare è abilitare la via in basso del MUX e come secondo operando abilitare il displacement: questo è contenuto nell’istruzione e viene estratto e cooertito a 32 bit nello stadio ID e passato allo stadio EX mediante il regsisto di pipeline ID/EX. Quindi dopo lo stadio EX il registro EX/MEM contiene il risultato dell’elaborazione, se è un’istruzione ALU, l’indirizzo se è una LOAD. MEM: se è una ALU, non bisogna accedere alla memoria: il risultato verrà semplicemente passato allo stadio WB attraverso il registro di pipeline MEM/WB. se è una LOAD, si accede alla memoria tramite l’indirizzo presente su EX/MEM ed il dato letto viene campionato poi sul registro MEM/WB. Stadio di WB: è attivo sia per una LOAD sia per un’istruzione di tipo ALU: in entrambi i casi bisogna scrivere sul Register File: nel primo caso il valore da scrivere è quello proveniente dalla data-memory, nel secondo caso è quello che è stato propagato dallo stadio EX: il MUX consente di selezionare fra i due valori quello che viene inviato sulla porta di scrittura del RF. L’identificatore del registro che deve essere scritto (campo Rd dell’istruzione) viene anch’esso dallo stadio WB, su cui è stato propagato da ID: difatti non possiamo usare il campo Rd dell’istruzione correntemente in ID Perché cosi’ facendo scriveremmo erroneamente sulla destinazione dell’istruzione correntemente in ID che non è qiuella di cui staimo seguendo l’evoluzione attraverso la pipeline ma bensi’ quella che la segue di 3 clock (è stata prelevata con 3 clock di ritardo) SE Y X: Computed data or Memory Address or Branch Address I R 2 I R 3 I R 4 Y: Computed data from the previous stage destination register number IF/ID ID/EX EX/MEM MEM/WB

25 Pipelined execution of an “ALU” instruction
IF IR <= M[PC] ; PC <= PC + 4 ; PC1 <= PC + 4 A <= RS1; B <= RS2; PC2 <= PC1; IR2<=IR1 ID/EX <= Instruction decode; ID NOTE: IRi bits which are dropped stage by stage when no more needed for all instructions. X <= A op B or X <= A op [(IR215)16 ## IR215..0] [PC3 <= PC2] EX [IR3 <= IR2] Decoded opcode travels through all stages MEM Y <= X (temp. Storage for WB) Why ? [IR4 <.= IR3] [PC4 <= PC3] WB RD <= Y X : “ALUOUTPUT” (in EX/MEM), Y : “ALUOUTPUT1”

26 Pipelined execution of a “MEM” instruction
IF IR <= M[PC] ; PC <= PC + 4 ; PC1 <= PC + 4 A <= RS1; B <= RS2; PC2 <= PC1; IR2<=IR1 ID/EX <= Instruction decode; ID MAR <= A op (IR215)16 ## IR215..0 SMDR <= B EX [IR3 <= IR2 [PC4 <= PC3] [PC3 <= PC2] Decoded opcode travels through all stages LMDR <= M[MAR] (if LOAD) or M[MAR] <= SMDR (if STORE) MEM [IR4 <= IR3] WB RD <= MDR (if LOAD) [Sign ext.]

27 Pipelined execution of a “BRANCH” instruction (normally after a SCn instruction – see later)
IF IR <= M[PC] ; PC <= PC + 4 ; PC1 <= PC + 4 A <= RS1; B <= RS2; PC2 <= PC1; IR2<=IR1 ID/EX <= Instruction decode; ID X <= PC2 op (IR15)16 ## IR15..0 Cond <= A op 0 [PC3 <= PC2] EX [IR3 <= IR2] Decoded opcode travels through all stages MEM if (Cond) PC <= X [PC4 <= PC3] [IR4 <= IR3 New value in PC in this interval . When Branch is taken 3 new unwanted instructions are already started (NOP) WB X : “BTA (BRANCH TARGET ADDRESS)” Branch on Reg A value (0/1)

28 Pipelined execution of a “JR” instruction
ID IF IR <= M[PC] ; PC <= PC + 4 ; PC1 <= PC + 4 A <= RS1; B <= RS2; PC2 <= PC1; IR2<=IR1 ID/EX <= Instruction decode; ID X <= A EX MEM [IR3 <= IR2] [PC4 <= PC3] [PC3 <= PC2] Decoded opcode travels through all stages WB MEM PC <= X [IR4 <= IR3] New value in PC in this interval . When Jump executed 3 new unwanted instructions are already started (NOP) WB Which would be the stage sequence for a J instruction?

29 Pipelined execution of a “JL or JLR” instruction
ID IF IR <= M[PC] ; PC <= PC + 4 ; PC1 <= PC + 4 A <= RS1; B <= RS2; PC2 <= P1; IR2<=IR1 ID/EX <= Instruction decode; ID PC3 <= PC2 X <= A (If JLR) X <= PC2 + (IR25)6 ## IR25..0 (If JL) [IR3 <= IR2] EX MEM PC <= X ; PC4<= PC3 [IR4 <= IR3] New value in PC in this interval . When Jump executed 3 new unwanted instructions are already started WB R31 <= PC4 In this case PCi values are used Decoded opcode through all stages NOTE: Write on R31 CANNOT be performed on-the fly since it could overlap with another register write

30 Which would be the sequence in case of SCn (ex SLT R1,R2,R3) ?
ID IF IR <= M[PC] ; PC <= PC + 4 ; PC1 <= PC + 4 A <= RS1; B <= RS2; PC2 <= P1; IR2<=IR1 ID/EX <= Instruction decode; ID EX ? MEM ? WB ?

31 Pipeline Hazards A “Hazard” occurs when during a clock cycle an instruction currently in a pipeline stage can’t be executed in the same clock cycle. Structural Hazards – The same resource is used by two different pipeline stages: the instructions currently in those stages can not be executed simultaneously. Data Hazards – they are due to instruction dependencies. For example, an instruction that needs to read a register not yet written by a previous instruction (Read After Write). Control Hazards – Instructions following a branch depend from the branch result (taken/not taken). L’indirizzo virtuale si compone di un page number ed un page offset. La traslazione avviene a livello di page number, l’offset rimane invariato. Il numero di bit del page offset determina la dimensione della pagina. Il numero di pagine indirizzabili con l’indirizzo virtuale non deve necessariamente essere Pari a quello indirizzabile con l’indirizzo fisico. Nel caso in cui lo sia, tipicamente la memoria fisica avrà comunque dimensioni minori dello spazio Virtuale, quindi in pratica, verrano usati meno indirizzi. Se anche la memoria fisica fosse pari allo spazio virtuale non dobbiamo dimenticare che La memoria virtuale fa si che più processsi vedano simultaneamente lo stesso spazio di indirizzamento virtuale, ragion per cui lo Spazio fisico sarà comunque insufficiente. The instruction that cannot be executed must be stalled (“pipeline stall” or “pipeline bubbling”), together with all the following instructions, while the previous instructions must proceed normally (so as to eliminate the hazard).

32 Hazards and stalls T5 = 8 * CLK = (5 + 3) * CLK
The consequence of a data hazard: if instruction Ii needs the result of instruction Ii-1 (data are read in ID stage), must wait until after WB of Ii-1 Clk 1 Clk 2 Clk 3 Clk 4 Clk 5 Clk 6 Clk 7 Clk 8 Clk 9 Clk 10 Clk 11 Clk 12 Ii-3 IF ID EX MEM WB Ii-2 IF ID EX MEM WB Ii-1 IF ID EX MEM WB ID Ii IF Ii+1 WB S Stall: the clock signal for Ii, Ii+1 …etc. is blocked for three periods T5 = 8 * CLK = (5 + 3) * CLK T5 = 5 * (1 + 3/5 ) * CLK Instruction stalls L’ESEMPIO CHE STIAMO CONSIDERANDO VIENE DAL LUCIDO PRECEDENTE: è UN’ALEA RAW DEL DLX: e spieghiamo bene la situazione. Poi il calcolo di sinistra, Che fa ancora riferimento al caso di sinistra. Infine, prima del clock che attiva la parte di destra la generalizzazione: le ALEE fanno si che un’istruzione non possa procedere nella pipeline a causa della presenza nella stessa di un’sitruzione precedente: l’istruzione e la quelle che la seguono devono essere stallate, quelle che la precdeno vanno avanti. L’istruzione rimane stallata fino a che il procedere delle istruzioni che la precedono non rimuove la causa dell’alea. Gli stalli introdotti nella pipeline riducono le prestazioni della pipeline stessa: da CPI=1 si va a CPI>1. Qui un discorso semplice del perché un set di istruzioni RISC porta ad un pipelining più efficiente: tanto più il set di istruzioni è complesso, vario, con istruzioni molto diverse fra loro tanto più queste daranno luogo a dipendenze se eseguite in pipeline. Poi la formula per le prestazioni con la percentuale di stalli.

33 Data are read from registers in the ID stage
Forwarding Data are read from registers in the ID stage Clk 6 Clk 7 Clk 8 MEM WB IF ID EX Clk 1 Clk 2 Clk 3 Clk 4 Clk 5 Clk 9 ADD R3, R1, R4 SUB R7, R3, R5 hazard ID OR R1, R3, R5 hazard ID LW R6, 100 (R3) hazard ID Here too the requested data is not yet in RF since it is written on the positive clock edge at the end of WB (register value is read in ID!) AND R9, R5, R3 no hazard Forwarding allows eliminating almost all RAW hazards of the pipeline without stalling the pipeline. (NOTE: in DLX, registers are modified only in WB stage)

34 Forwarding implementation
Comparison between RS1, RS2 and RD1, RD2 and the Opcodes Alternatively, SPLIT-CYCLE (see next slide) write before read RD1 (destination register/OpCode) RD2/OpCode FU1 RS1/RS2 OPCODE IR3 IR4 Bypass RF M U X A M U X Memory A L U B M U X M U X M U X M U X ALU Offset ID/EX EX/MEM MEM/WB Often performed inside the RF It allows “the anticipation” of the register on ID/EX MUX control: IF/ID opcode and comparison of RD with RS1 and RS2

35 Data hazard due to LOAD instructions
LW R1,32(R6) MEM WB IF ID EX ADD R4,R1,R7 SUB R5,R1,R8 AND R6,R1,R7 NOTE: the data required by the ADD is available only at the end of MEM stage. This hazard cannot be eliminated by forwarding (unless there is an additional input in the MUXs between memory and ALU – delays!) Actually the clock signal is not generated. The clock block is propagated along the pipeline one stage at a time. LW R1,32(R6) ADD R4,R1,R7 SUB R5,R1,R8 AND R6,R1,R7 IF ID EX MEM WB S The pipeline needs to be stalled From the end of this stage onwards: standard forwarding

36 with a “useful” instruction
Delayed load In many RISC CPUs, the hazard associated with the LOAD instruction is not handled by HW by stalling the pipeline but by software through the compiler (delayed load): LOAD Instruction The compiler tries to fill the delay-slot with a “useful” instruction (worst case: NOP). delay slot Next instruction LW R1,32(R6) LW R3,10 (R4) ADD R5,R1,R3 LW R6, 20 (R7) LW R8, 40(R9) LW R1,32(R6) LW R3,10 (R4) ADD R5,R1,R3 LW R6, 20 (R7) LW R8, 40(R9)

37 Control Hazards PC BEQZ R4, 200 PC+4 SUB R7, R3, R5 PC+8 OR R1, R3, R5
Next Instruction Address PC BEQZ R4, 200 R4 = 0 : Branch Target Address (taken) R4  0 : PC+4 (not taken) PC+4 SUB R7, R3, R5 PC+8 OR R1, R3, R5 PC+12 LW R6, 100 (R8) PC AND R9, R5, R3 (BTA) New computed PC value (Aluout) New value in PC (one clock after) Clk 1 Clk 2 Clk 3 Clk 4 Clk 5 Clk 6 Clk 7 Clk 8 Fetch with the new PC BEQZ R4, 200 IF ID EX MEM WB SUB R7, R3, R5 IF ID ID EX MEM WB L’indirizzo della prossima istruzione è noto solo quando è terminata l’istruzione di branch, , ma l’esecuzione in pipeline implica il fetch di una nuova istruzione ad ogni ciclo di clock OR R1, R3, R5 IF ID ID EX MEM WB LW R6, 100 (R8) ID IF EX WB MEM ID IF EX WB MEM

38 DLX Pipelined Datapath (Branch or JMP)
NOTE if the feedback signal of the new PC were output directly from the ALU instead than from ALUOUT the required stalls would be only two – slower clock! Instruction Fetch Instruction Decode Execute Write Back Memory BEQZ R4, 200 4 A D M U X DEC M U X =0? =0? PC M U X DM A L U IM RF M U X When the new PC acts on the IM three instructions have already travelled through the first three stages (EX included) SE IF/ID ID/EX EX/MEM MEM/WB

39 Handling the Control Hazards
Always Stall (three-clock block being propagated) Fetch at new PC Clk 1 Clk 2 Clk 3 Clk 4 Clk 5 Clk 6 Clk 7 Clk 8 IF BEQZ R4,200 ID EX MEM WB S IF ID IF here: the previous instruction has not been yet decoded Real situation Repeated IF PC <= PC - 4 S S S IF Here the new value is sampled by the PC Branch Completion Predict Not Taken Clk 1 Clk 2 Clk 3 Clk 4 Clk 5 Clk 6 Clk 7 Clk 8 Flush: they become NOP BEQZ R4, 200 IF ID EX MEM WB NOP IF ID ID EX MEM WB SUB R7, R3, R5 NOP IF ID EX MEM WB OR R1, R3, R5 ID NOP IF ID ID EX MEM WB LW R6, 100 (R8) No problem because no instruction in WB stage

40 Three NOPs MUST replace the 3 unwanted instructions already started
Stalls with jumps (1/3) When the Branch Target Address is clocked into the PC three unwanted instructions are already in IF/ID, ID/EX and EX/MEM IF ID EX MEM WB if jump Jump forced NOP N O P N O P N O P 4 A D M U X PC DEC =0? =0? INSTR MEM RF PC M U X RS1 A L U RS2 DATA MEM M U X DR M U X D I passi in cui viene suddivisa l’esecuzione di un’istruzione DLX sono quelli che abbiamo anticipato precedentemente: click , vengono giù. Come già anticipato, ogni passo Dell’esecuzione dell’istruzione viene eseguito da un’unità funzionale detta stadio click ed appaiono gli stadi; per consentire agli sia stadi di operarare simultaneamente su istruzioni diverse sia di scambiarsi informazioni fra gli stadi vengono inseriti dei registri, detti pipeline registers. Per semplicità pensiamo che siano dei registri edge-triggered che camponano sui fronti del clock della CPU, anche se è possibile utilizzare dei latch ed una diversa strategia di clocking. In un generico ciclo di clock ogni stadio elabora le informazioni presenti sul suo registro di ingresso, relative ad una data istruzione K e produce delle nuove informazioni, anch’esse relative all’istruzione K: all’inizio del ciclo successive queste informazioni vengono campionate sul regsitro d’uscita dello stadio, che è il regsistro d’ingresso dello stadio successivo: in questo modo lo stadio successivo esegue il passo che gli compete dell’istruzione K. Lo stadio su cui abbiamo focalizzato la nostra attenzione campionerà invece le informazioni provenienti dallo stadio a valle ed eseguirà il proprio passo sull’istruzione precedente (K-1). In sostanza, grazie ad i registri di pipeliene, in un dato ciclo ogni stadio lavora su informazioni relative ad un’istruzione diversa, e le istruzioni presenti nella pipeline avanzano di uno stadio ad ogni clock. L’uso dei pipeline regsister non è specifico del datapath dl DLX, ogni CPU in pipeline usa questi registri per trasportare le informazioni relative ad una sequenza di istruzioni attraverso gli stadi della pipeline. Vediamo invece ora come sono fatti gli stadi della pipeline del DLX. I primi due stadi sono indipendenti dal tipo di istruzione, mentre il tipo di elaborazione che viene eseguito nei 3 stadi successivi dipende dal tipo di istruszione. Ci limiteremo a 2 delle 3 istruzioni che abbiamo introdotto precedentemente: ALU e LOAD. Discuteremo successivamente il caso dei BRANCH. IF: Il PC fornisce l’indirizzo usato per accedere alla IM e prelevare l’istruzione: simultaneamente il PC viene incrementato al fine di ottenere l’indirizzo che sarà usato Per prelevare la prossima istruzione. Ignoriamo per ora la presenza del MUX. ID: l’istruzione prelevata nello stadio IF viene campionata su IF/ID e decodificata nello stadio ID: la rete di decodifica genera i segnali di controllo che vengono propagati verso tutti gli stadi attraverso i regsitri: in ID il decoder genera i segnali che verranno poi utilizzati nei vari stadi man mano che l’istruzione procede nella pipeline. Quasi tutte le istruzioni del DLX prevedono l’accesso in lettura ad uno o due registri: i campi dell’istruzione che specificano i registri da leggere occupano una posizione fissa nell’istruzione e nettamente separata dall’opcode: è possibile allora utilizzare questi campi per accedere ai regsitri e prelevare gli operandi dell’istruzione simultaneamente alla fase di decodifica: leggiamo gli operandi mentre siamo decodificando l’istruzione, senza sapere bene ancora cosa dovremo fare: poco male, se ci servirà un solo operando, o nessuno non li useremo, ma non ci costa nulla leggerli. I tre stadi successivi sono dipendenti dall’ istruzione: istruzione ALU: dobbiamo eseguire un’operazione logico/aritmetica sui registri letti in ID: i MUX selezioneranno come ingressi della ALU i valori dei registri provenienti dal regsitro ID/EX i segnali di controllo della ALU, provenienti dallo stadio precedente, selezioneranno l’operazione da eseguire: il risultato sarà pronto all’uscita della ALU alla fine del ciclio di clock e camponato sul regsitri EX/MEM all’inizio del clock successivo. Se l’istruzione è una LOAD, lo stadio EX è usato per calcolare l’indirizzo: ricordando che la modalità di indirizzamento è displacement, e che il registro che contiene la base dell’indirizzo è già stato letto in ID, quello che è necessario fare è abilitare la via in basso del MUX e come secondo operando abilitare il displacement: questo è contenuto nell’istruzione e viene estratto e cooertito a 32 bit nello stadio ID e passato allo stadio EX mediante il regsisto di pipeline ID/EX. Quindi dopo lo stadio EX il registro EX/MEM contiene il risultato dell’elaborazione, se è un’istruzione ALU, l’indirizzo se è una LOAD. MEM: se è una ALU, non bisogna accedere alla memoria: il risultato verrà semplicemente passato allo stadio WB attraverso il registro di pipeline MEM/WB. se è una LOAD, si accede alla memoria tramite l’indirizzo presente su EX/MEM ed il dato letto viene campionato poi sul registro MEM/WB. Stadio di WB: è attivo sia per una LOAD sia per un’istruzione di tipo ALU: in entrambi i casi bisogna scrivere sul Register File: nel primo caso il valore da scrivere è quello proveniente dalla data-memory, nel secondo caso è quello che è stato propagato dallo stadio EX: il MUX consente di selezionare fra i due valori quello che viene inviato sulla porta di scrittura del RF. L’identificatore del registro che deve essere scritto (campo Rd dell’istruzione) viene anch’esso dallo stadio WB, su cui è stato propagato da ID: difatti non possiamo usare il campo Rd dell’istruzione correntemente in ID Perché cosi’ facendo scriveremmo erroneamente sulla destinazione dell’istruzione correntemente in ID che non è qiuella di cui staimo seguendo l’evoluzione attraverso la pipeline ma bensi’ quella che la segue di 3 clock (è stata prelevata con 3 clock di ritardo) Three NOPs MUST replace the 3 unwanted instructions already started SE Data IF/ID ID/EX EX/MEM MEM/WB

41 Two NOPs MUST replace the 2 unwanted instructions already started
Stalls with jump (2/3) NOTE in this case the jump condition detection and the new PC value are input to the MUX in the same clok interval IF ID EX MEM WB if jump forced NOP when jump N O P N O P 4 A D M U X PC DEC =0? =0? INSTR MEM RF PC M U X RS1 A L U RS2 DATA MEM M U X DR M U X D I passi in cui viene suddivisa l’esecuzione di un’istruzione DLX sono quelli che abbiamo anticipato precedentemente: click , vengono giù. Come già anticipato, ogni passo Dell’esecuzione dell’istruzione viene eseguito da un’unità funzionale detta stadio click ed appaiono gli stadi; per consentire agli sia stadi di operarare simultaneamente su istruzioni diverse sia di scambiarsi informazioni fra gli stadi vengono inseriti dei registri, detti pipeline registers. Per semplicità pensiamo che siano dei registri edge-triggered che camponano sui fronti del clock della CPU, anche se è possibile utilizzare dei latch ed una diversa strategia di clocking. In un generico ciclo di clock ogni stadio elabora le informazioni presenti sul suo registro di ingresso, relative ad una data istruzione K e produce delle nuove informazioni, anch’esse relative all’istruzione K: all’inizio del ciclo successive queste informazioni vengono campionate sul regsitro d’uscita dello stadio, che è il regsistro d’ingresso dello stadio successivo: in questo modo lo stadio successivo esegue il passo che gli compete dell’istruzione K. Lo stadio su cui abbiamo focalizzato la nostra attenzione campionerà invece le informazioni provenienti dallo stadio a valle ed eseguirà il proprio passo sull’istruzione precedente (K-1). In sostanza, grazie ad i registri di pipeliene, in un dato ciclo ogni stadio lavora su informazioni relative ad un’istruzione diversa, e le istruzioni presenti nella pipeline avanzano di uno stadio ad ogni clock. L’uso dei pipeline regsister non è specifico del datapath dl DLX, ogni CPU in pipeline usa questi registri per trasportare le informazioni relative ad una sequenza di istruzioni attraverso gli stadi della pipeline. Vediamo invece ora come sono fatti gli stadi della pipeline del DLX. I primi due stadi sono indipendenti dal tipo di istruzione, mentre il tipo di elaborazione che viene eseguito nei 3 stadi successivi dipende dal tipo di istruszione. Ci limiteremo a 2 delle 3 istruzioni che abbiamo introdotto precedentemente: ALU e LOAD. Discuteremo successivamente il caso dei BRANCH. IF: Il PC fornisce l’indirizzo usato per accedere alla IM e prelevare l’istruzione: simultaneamente il PC viene incrementato al fine di ottenere l’indirizzo che sarà usato Per prelevare la prossima istruzione. Ignoriamo per ora la presenza del MUX. ID: l’istruzione prelevata nello stadio IF viene campionata su IF/ID e decodificata nello stadio ID: la rete di decodifica genera i segnali di controllo che vengono propagati verso tutti gli stadi attraverso i regsitri: in ID il decoder genera i segnali che verranno poi utilizzati nei vari stadi man mano che l’istruzione procede nella pipeline. Quasi tutte le istruzioni del DLX prevedono l’accesso in lettura ad uno o due registri: i campi dell’istruzione che specificano i registri da leggere occupano una posizione fissa nell’istruzione e nettamente separata dall’opcode: è possibile allora utilizzare questi campi per accedere ai regsitri e prelevare gli operandi dell’istruzione simultaneamente alla fase di decodifica: leggiamo gli operandi mentre siamo decodificando l’istruzione, senza sapere bene ancora cosa dovremo fare: poco male, se ci servirà un solo operando, o nessuno non li useremo, ma non ci costa nulla leggerli. I tre stadi successivi sono dipendenti dall’ istruzione: istruzione ALU: dobbiamo eseguire un’operazione logico/aritmetica sui registri letti in ID: i MUX selezioneranno come ingressi della ALU i valori dei registri provenienti dal regsitro ID/EX i segnali di controllo della ALU, provenienti dallo stadio precedente, selezioneranno l’operazione da eseguire: il risultato sarà pronto all’uscita della ALU alla fine del ciclio di clock e camponato sul regsitri EX/MEM all’inizio del clock successivo. Se l’istruzione è una LOAD, lo stadio EX è usato per calcolare l’indirizzo: ricordando che la modalità di indirizzamento è displacement, e che il registro che contiene la base dell’indirizzo è già stato letto in ID, quello che è necessario fare è abilitare la via in basso del MUX e come secondo operando abilitare il displacement: questo è contenuto nell’istruzione e viene estratto e cooertito a 32 bit nello stadio ID e passato allo stadio EX mediante il regsisto di pipeline ID/EX. Quindi dopo lo stadio EX il registro EX/MEM contiene il risultato dell’elaborazione, se è un’istruzione ALU, l’indirizzo se è una LOAD. MEM: se è una ALU, non bisogna accedere alla memoria: il risultato verrà semplicemente passato allo stadio WB attraverso il registro di pipeline MEM/WB. se è una LOAD, si accede alla memoria tramite l’indirizzo presente su EX/MEM ed il dato letto viene campionato poi sul registro MEM/WB. Stadio di WB: è attivo sia per una LOAD sia per un’istruzione di tipo ALU: in entrambi i casi bisogna scrivere sul Register File: nel primo caso il valore da scrivere è quello proveniente dalla data-memory, nel secondo caso è quello che è stato propagato dallo stadio EX: il MUX consente di selezionare fra i due valori quello che viene inviato sulla porta di scrittura del RF. L’identificatore del registro che deve essere scritto (campo Rd dell’istruzione) viene anch’esso dallo stadio WB, su cui è stato propagato da ID: difatti non possiamo usare il campo Rd dell’istruzione correntemente in ID Perché cosi’ facendo scriveremmo erroneamente sulla destinazione dell’istruzione correntemente in ID che non è qiuella di cui staimo seguendo l’evoluzione attraverso la pipeline ma bensi’ quella che la segue di 3 clock (è stata prelevata con 3 clock di ritardo) Two NOPs MUST replace the 2 unwanted instructions already started SE Data IF/ID ID/EX EX/MEM MEM/WB

42 A NOP MUST replace the unwanted instruction already started
Stalls with jump (3/3) NOTE In this case the jump condition and the new PC act on the MUX in the same period when the condition is detected Very slow solution ! IF ID EX MEM WB if jump NOP for jump 4 A D N O P PC M U X DEC =0? =0? INSTR MEM RF PC M U X RS1 A L U RS2 DATA MEM M U X DR M U X D I passi in cui viene suddivisa l’esecuzione di un’istruzione DLX sono quelli che abbiamo anticipato precedentemente: click , vengono giù. Come già anticipato, ogni passo Dell’esecuzione dell’istruzione viene eseguito da un’unità funzionale detta stadio click ed appaiono gli stadi; per consentire agli sia stadi di operarare simultaneamente su istruzioni diverse sia di scambiarsi informazioni fra gli stadi vengono inseriti dei registri, detti pipeline registers. Per semplicità pensiamo che siano dei registri edge-triggered che camponano sui fronti del clock della CPU, anche se è possibile utilizzare dei latch ed una diversa strategia di clocking. In un generico ciclo di clock ogni stadio elabora le informazioni presenti sul suo registro di ingresso, relative ad una data istruzione K e produce delle nuove informazioni, anch’esse relative all’istruzione K: all’inizio del ciclo successive queste informazioni vengono campionate sul regsitro d’uscita dello stadio, che è il regsistro d’ingresso dello stadio successivo: in questo modo lo stadio successivo esegue il passo che gli compete dell’istruzione K. Lo stadio su cui abbiamo focalizzato la nostra attenzione campionerà invece le informazioni provenienti dallo stadio a valle ed eseguirà il proprio passo sull’istruzione precedente (K-1). In sostanza, grazie ad i registri di pipeliene, in un dato ciclo ogni stadio lavora su informazioni relative ad un’istruzione diversa, e le istruzioni presenti nella pipeline avanzano di uno stadio ad ogni clock. L’uso dei pipeline regsister non è specifico del datapath dl DLX, ogni CPU in pipeline usa questi registri per trasportare le informazioni relative ad una sequenza di istruzioni attraverso gli stadi della pipeline. Vediamo invece ora come sono fatti gli stadi della pipeline del DLX. I primi due stadi sono indipendenti dal tipo di istruzione, mentre il tipo di elaborazione che viene eseguito nei 3 stadi successivi dipende dal tipo di istruszione. Ci limiteremo a 2 delle 3 istruzioni che abbiamo introdotto precedentemente: ALU e LOAD. Discuteremo successivamente il caso dei BRANCH. IF: Il PC fornisce l’indirizzo usato per accedere alla IM e prelevare l’istruzione: simultaneamente il PC viene incrementato al fine di ottenere l’indirizzo che sarà usato Per prelevare la prossima istruzione. Ignoriamo per ora la presenza del MUX. ID: l’istruzione prelevata nello stadio IF viene campionata su IF/ID e decodificata nello stadio ID: la rete di decodifica genera i segnali di controllo che vengono propagati verso tutti gli stadi attraverso i regsitri: in ID il decoder genera i segnali che verranno poi utilizzati nei vari stadi man mano che l’istruzione procede nella pipeline. Quasi tutte le istruzioni del DLX prevedono l’accesso in lettura ad uno o due registri: i campi dell’istruzione che specificano i registri da leggere occupano una posizione fissa nell’istruzione e nettamente separata dall’opcode: è possibile allora utilizzare questi campi per accedere ai regsitri e prelevare gli operandi dell’istruzione simultaneamente alla fase di decodifica: leggiamo gli operandi mentre siamo decodificando l’istruzione, senza sapere bene ancora cosa dovremo fare: poco male, se ci servirà un solo operando, o nessuno non li useremo, ma non ci costa nulla leggerli. I tre stadi successivi sono dipendenti dall’ istruzione: istruzione ALU: dobbiamo eseguire un’operazione logico/aritmetica sui registri letti in ID: i MUX selezioneranno come ingressi della ALU i valori dei registri provenienti dal regsitro ID/EX i segnali di controllo della ALU, provenienti dallo stadio precedente, selezioneranno l’operazione da eseguire: il risultato sarà pronto all’uscita della ALU alla fine del ciclio di clock e camponato sul regsitri EX/MEM all’inizio del clock successivo. Se l’istruzione è una LOAD, lo stadio EX è usato per calcolare l’indirizzo: ricordando che la modalità di indirizzamento è displacement, e che il registro che contiene la base dell’indirizzo è già stato letto in ID, quello che è necessario fare è abilitare la via in basso del MUX e come secondo operando abilitare il displacement: questo è contenuto nell’istruzione e viene estratto e cooertito a 32 bit nello stadio ID e passato allo stadio EX mediante il regsisto di pipeline ID/EX. Quindi dopo lo stadio EX il registro EX/MEM contiene il risultato dell’elaborazione, se è un’istruzione ALU, l’indirizzo se è una LOAD. MEM: se è una ALU, non bisogna accedere alla memoria: il risultato verrà semplicemente passato allo stadio WB attraverso il registro di pipeline MEM/WB. se è una LOAD, si accede alla memoria tramite l’indirizzo presente su EX/MEM ed il dato letto viene campionato poi sul registro MEM/WB. Stadio di WB: è attivo sia per una LOAD sia per un’istruzione di tipo ALU: in entrambi i casi bisogna scrivere sul Register File: nel primo caso il valore da scrivere è quello proveniente dalla data-memory, nel secondo caso è quello che è stato propagato dallo stadio EX: il MUX consente di selezionare fra i due valori quello che viene inviato sulla porta di scrittura del RF. L’identificatore del registro che deve essere scritto (campo Rd dell’istruzione) viene anch’esso dallo stadio WB, su cui è stato propagato da ID: difatti non possiamo usare il campo Rd dell’istruzione correntemente in ID Perché cosi’ facendo scriveremmo erroneamente sulla destinazione dell’istruzione correntemente in ID che non è qiuella di cui staimo seguendo l’evoluzione attraverso la pipeline ma bensi’ quella che la segue di 3 clock (è stata prelevata con 3 clock di ritardo) A NOP MUST replace the unwanted instruction already started SE Data IF/ID ID/EX EX/MEM MEM/WB

43 with “useful” instructions
Delayed branch Similarly to the LOAD case. In several RISC CPUs the BRANCH instructions hazard is handled by SW thorugh the compiler (delayed branch): BRANCH instruction delay slot The compiler tries to fill the delay-slots with “useful” instructions (worst case: NOP). delay slot delay slot Next instruction

44 Obviously in this instructions group there must be no jumps!!!
Delayed branch/jump Original Compiled Add R5, R4, R3 Sub R6, R5, R2 Or R14, R6, R21 Sne R1, R8, R9 ; branch condition Br R1, +100 Sne R1, R8, R9 ; branch condition Br R1, +100 Add R5, R4, R3 Sub R6, R5, R2 Or R14, R6, R21 Obviously in this instructions group there must be no jumps!!! Executed in both cases Instead of one or more “postponed” instructions, the compiler inserts NOPs when no suitable instructions are available

45 -------------------------
NOTE: in this case there is only one “stall” since the new value is inserted in the PC on the positive clock edge that ends the ID stage while, in the previous case, it was inserted after the MEM stage, that is, two clock later!!!!!! To reduce the number of stalls Independent Adder for BRANCH/JMP IF IR <- M[PC] ; PC <- PC + 4; PC1 <- PC + 4 A <- RS1; B <- RS2; PC2 <- PC1 ID/EX <- Decode; ID/EX <- Opc ext. ID BTA <=PC1+ (IR15)16 ## IR15-0 /(IR25)6 ## IR25..0 (New fetch only one stall) if Branch: if (RS1 op 0) PC <= BTA if JMP always PC <= BTA EX ALU (additional full adder) MEM WB

46 Offset and sign extension
BRANCH/JMP – 1 stall The source of the next PC is selected according to the opcode and the value of the branch test register Standard increment ID IF Displacement of the Branch instruction PC of the Branch instruction M U X A D E R 4 P C 2 P C 1 M U X DEC ## Branch PC Offset and sign extension I R 1 A IM RF B = 0 ? NOTE: for “Unconditional Jump” instructions there a similar situation : we need only to provide further inputs to the MUXs of the PC by considering either the RS1 register (JR and JRL) or the 26 less-significant bits of the IR with SE (J and JL) to be added to the instruction PC (not the current PC) I passi in cui viene suddivisa l’esecuzione di un’istruzione DLX sono quelli che abbiamo anticipato precedentemente: click , vengono giù. Come già anticipato, ogni passo Dell’esecuzione dell’istruzione viene eseguito da un’unità funzionale detta stadio click ed appaiono gli stadi; per consentire agli sia stadi di operarare simultaneamente su istruzioni diverse sia di scambiarsi informazioni fra gli stadi vengono inseriti dei registri, detti pipeline registers. Per semplicità pensiamo che siano dei registri edge-triggered che camponano sui fronti del clock della CPU, anche se è possibile utilizzare dei latch ed una diversa strategia di clocking. In un generico ciclo di clock ogni stadio elabora le informazioni presenti sul suo registro di ingresso, relative ad una data istruzione K e produce delle nuove informazioni, anch’esse relative all’istruzione K: all’inizio del ciclo successive queste informazioni vengono campionate sul regsitro d’uscita dello stadio, che è il regsistro d’ingresso dello stadio successivo: in questo modo lo stadio successivo esegue il passo che gli compete dell’istruzione K. Lo stadio su cui abbiamo focalizzato la nostra attenzione campionerà invece le informazioni provenienti dallo stadio a valle ed eseguirà il proprio passo sull’istruzione precedente (K-1). In sostanza, grazie ad i registri di pipeliene, in un dato ciclo ogni stadio lavora su informazioni relative ad un’istruzione diversa, e le istruzioni presenti nella pipeline avanzano di uno stadio ad ogni clock. L’uso dei pipeline regsister non è specifico del datapath dl DLX, ogni CPU in pipeline usa questi registri per trasportare le informazioni relative ad una sequenza di istruzioni attraverso gli stadi della pipeline. Vediamo invece ora come sono fatti gli stadi della pipeline del DLX. I primi due stadi sono indipendenti dal tipo di istruzione, mentre il tipo di elaborazione che viene eseguito nei 3 stadi successivi dipende dal tipo di istruszione. Ci limiteremo a 2 delle 3 istruzioni che abbiamo introdotto precedentemente: ALU e LOAD. Discuteremo successivamente il caso dei BRANCH. IF: Il PC fornisce l’indirizzo usato per accedere alla IM e prelevare l’istruzione: simultaneamente il PC viene incrementato al fine di ottenere l’indirizzo che sarà usato Per prelevare la prossima istruzione. Ignoriamo per ora la presenza del MUX. ID: l’istruzione prelevata nello stadio IF viene campionata su IF/ID e decodificata nello stadio ID: la rete di decodifica genera i segnali di controllo che vengono propagati verso tutti gli stadi attraverso i regsitri: in ID il decoder genera i segnali che verranno poi utilizzati nei vari stadi man mano che l’istruzione procede nella pipeline. Quasi tutte le istruzioni del DLX prevedono l’accesso in lettura ad uno o due registri: i campi dell’istruzione che specificano i registri da leggere occupano una posizione fissa nell’istruzione e nettamente separata dall’opcode: è possibile allora utilizzare questi campi per accedere ai regsitri e prelevare gli operandi dell’istruzione simultaneamente alla fase di decodifica: leggiamo gli operandi mentre siamo decodificando l’istruzione, senza sapere bene ancora cosa dovremo fare: poco male, se ci servirà un solo operando, o nessuno non li useremo, ma non ci costa nulla leggerli. I tre stadi successivi sono dipendenti dall’ istruzione: istruzione ALU: dobbiamo eseguire un’operazione logico/aritmetica sui registri letti in ID: i MUX selezioneranno come ingressi della ALU i valori dei registri provenienti dal regsitro ID/EX i segnali di controllo della ALU, provenienti dallo stadio precedente, selezioneranno l’operazione da eseguire: il risultato sarà pronto all’uscita della ALU alla fine del ciclio di clock e camponato sul regsitri EX/MEM all’inizio del clock successivo. Se l’istruzione è una LOAD, lo stadio EX è usato per calcolare l’indirizzo: ricordando che la modalità di indirizzamento è displacement, e che il registro che contiene la base dell’indirizzo è già stato letto in ID, quello che è necessario fare è abilitare la via in basso del MUX e come secondo operando abilitare il displacement: questo è contenuto nell’istruzione e viene estratto e cooertito a 32 bit nello stadio ID e passato allo stadio EX mediante il regsisto di pipeline ID/EX. Quindi dopo lo stadio EX il registro EX/MEM contiene il risultato dell’elaborazione, se è un’istruzione ALU, l’indirizzo se è una LOAD. MEM: se è una ALU, non bisogna accedere alla memoria: il risultato verrà semplicemente passato allo stadio WB attraverso il registro di pipeline MEM/WB. se è una LOAD, si accede alla memoria tramite l’indirizzo presente su EX/MEM ed il dato letto viene campionato poi sul registro MEM/WB. Stadio di WB: è attivo sia per una LOAD sia per un’istruzione di tipo ALU: in entrambi i casi bisogna scrivere sul Register File: nel primo caso il valore da scrivere è quello proveniente dalla data-memory, nel secondo caso è quello che è stato propagato dallo stadio EX: il MUX consente di selezionare fra i due valori quello che viene inviato sulla porta di scrittura del RF. L’identificatore del registro che deve essere scritto (campo Rd dell’istruzione) viene anch’esso dallo stadio WB, su cui è stato propagato da ID: difatti non possiamo usare il campo Rd dell’istruzione correntemente in ID Perché cosi’ facendo scriveremmo erroneamente sulla destinazione dell’istruzione correntemente in ID che non è qiuella di cui staimo seguendo l’evoluzione attraverso la pipeline ma bensi’ quella che la segue di 3 clock (è stata prelevata con 3 clock di ritardo) For Branches SE IF/ID ID/EX

47 Handling the Control Hazards
Dynamic Prediction: Branch Target Buffer => no stall (almost..) PC Predicted PC T/NT N.B. Here the branch slot is selected during the IF clock cycle that loads IR1 in IF/ID TAGS = HIT : Fetch with predicted PC MISS : Fetch with PC + 4 Correct prediction : no stalls Wrong prediction : stalls (correct fetch in ID or EX, see before)

48 when last branch occurred.
Prediction Buffer: the simplest implementation uses a single bit that indicates what happened when last branch occurred. When the program ends loop2, the prediction fails (branch predicted as taken but actually it is untaken), then it fails again when it predicts as untaken whilst entering once again loop2 Loop1 Loop2 In case of predominance of one prediction, when the opposite situation occurs we have two consecutive errors.

49 Usually two bits. TAKEN UNTAKEN TAKEN TAKEN TAKEN TAKEN UNTAKEN


Download ppt "DLX computer Electronic Computers M."