© WWW.MINDTUNER.NET MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV www.mindtuner.net
2
© WWW.MINDTUNER.NET Page: 2 MindTuner X1-10 Up to 8 channels EEG 1 ECG channel 1 EMG channel 1 GSR channel 1 TEMP channel Total 10 channels www.mindtuner.net The 10 channel solution
3
© WWW.MINDTUNER.NET Page: 3 MindTuner X1-10 Specifications 10 Channel EEG-Biofeedback 6-8 EEG 1 ECG, EMG, GSR, TEMP Dual 24-bits signal conversion Variable sampling rate Up to 13.000 samples/sec. total HW capacity USB connection System inter-connectability Software compatibility MindTuner software Bio-Explorer Neuroguide Labview More to follow soon
4
© WWW.MINDTUNER.NET Page: 4 EEG-Biofeedback features 8 Channel EEG training Combined bio-feedback EEG-ECG-EMG-GSR-TEMP Wide variety of protocols amplitude standard deviation coherence binaural beats ratio similarity synchrony comodulation etc. Mini QEEG Programmed for flexibility
5
© WWW.MINDTUNER.NET Page: 5 MindTuner Software MindTuner software
6
© WWW.MINDTUNER.NET Page: 6 Sequentiële – Bipolaire montage
7
© WWW.MINDTUNER.NET Page: 7 Multiple Channel view
8
© WWW.MINDTUNER.NET Page: 8 Session Summary
9
© WWW.MINDTUNER.NET Page: 9 Spectrum analyze
10
© WWW.MINDTUNER.NET Page: 10 Ratio Training
11
© WWW.MINDTUNER.NET Page: 11 Standard Deviation training
12
© WWW.MINDTUNER.NET Page: 12 Band Coherence
13
© WWW.MINDTUNER.NET Page: 13 Feedback Movies/games Feedback options
14
© WWW.MINDTUNER.NET Page: 14 movies
15
© WWW.MINDTUNER.NET Page: 15 Walker / Pacman variant
16
© WWW.MINDTUNER.NET Page: 16 Mini QEEG
17
© WWW.MINDTUNER.NET Page: 17 Mini QEEG Assessment
18
© WWW.MINDTUNER.NET Page: 18 Evaluation
19
© WWW.MINDTUNER.NET Page: 19 Assessment maps
20
© WWW.MINDTUNER.NET Page: 20 ECG, EMG, GSR, Temperature ECG, EMG, GSR and temperature
21
© WWW.MINDTUNER.NET Page: 21 ECG
22
© WWW.MINDTUNER.NET Page: 22 EMG, Galvanic skin response and Temperature
23
© WWW.MINDTUNER.NET Page: 23 EXTRA’S Extra’s
24
© WWW.MINDTUNER.NET Page: 24 Connection test
25
© WWW.MINDTUNER.NET Page: 25 Location
26
© WWW.MINDTUNER.NET Page: 26 Session Comments
27
© WWW.MINDTUNER.NET Page: 27 Artifact
28
© WWW.MINDTUNER.NET Page: 28 Define Bands
29
© WWW.MINDTUNER.NET Page: 29 Midi Setings
30
© WWW.MINDTUNER.NET Page: 30 Binaural Sounds
31
© WWW.MINDTUNER.NET Page: 31 Input channels10 EEG6(+2) – channel ECG1 – channel EMG1 – channel Galvanic Skin Response channel1 – channel Temperature channel1 – channel EEG band pass0,16 to 40 Hz ECG band pass0,16 to 40 Hz EMG band pass0,16 to 1000 Hz GSR range 0-200 µSiemens TEMP range 0-70 C Input Impedance 10 G Ohm Driven Right Leg frequency50 / 60 Hz Notch filter50 / 60 Hz 24 bits ADCs 2 Average power consumption0,75 W Common Mode Rejection116 dB Sampling frequency 1,024 samples / sec / channel max 13,000 samples / sec / MindTuner unit PC connectionUSB 1.1 / 2.0 compatible Power source5V USB Optical isolation8000 V Amplifier failure protection< 50 µA Electrode impedance test250 Ohm to 1 M Ohm Dimensions (l * w * h)180 * 206 * 64 mm MindTuner X1-10 - technical specifications
32
© WWW.MINDTUNER.NET Page: 32 Thank you for your attention www.mindtuner.net