Download presentation
Presentation is loading. Please wait.
Published byKaylie Lorton Modified over 10 years ago
1
Institute for Biomedical Engineering EXCITE Afternoon Hands-On MRI Sessions: fMRI & DTI
2
Institute for Biomedical Engineering Contrast in MRI - Relevant Parameters Relaxation times: T1Spin-lattice relaxation time (longitudinal relaxation time) Return of spin system to equilibrium state T2Spin-spin relaxation time (transverse relaxation time) Loss of phase coherence due to fluctuations of interacting spins (‘phase memory time’) T2*Decay time of free induction decay Signal loss due to magnetic field inhomogeneity (difference in magnetic susceptibility) ADCApparent diffusion coefficient Signal loss due to diffusion of water molecules in an inhomogeneous magnetic field kwater exchange rate Exchange of water between macromolecule bound fraction and bulk (free) water
3
Institute for Biomedical Engineering Sensitivity: Signal-to-Noise Ratio (SNR) Spatial resolution Temporal resolution Signal: magnetization (number of spins, magnetic field strength, …. ) Noise: thermal noise of receiver system, physiological noise, … Relations and Limitations
4
Institute for Biomedical Engineering IBT MRI Contrast
5
Institute for Biomedical Engineering MRI delivers good soft tissue contrast Tissue specific magnetic parameters for contrast generation T2 / T2*: how fast is signal lost after excitation T1: how fast is magnetization gained back after excitation for next experiments Sequence parameters and sequence type determine contrast Relaxation times
6
Institute for Biomedical Engineering 0 0.5 1.0 +1.0 0.0 time (s) M i (t)/M eq MxMx MyMy MzMz The NMR signal Relaxation exp(-t/T 2 *) 1-exp(-t/T 1 )
7
Institute for Biomedical Engineering Relevant parameters: Repetition time (TR) = time between two excitations Flip angle -> how much magnetization is left for next excitation Strong T1 weighting for large flip angle and short TR T1 weighting M xy MzMz M zA M zB θ T 1 Relaxation during TR
8
Institute for Biomedical Engineering T1 weighting: Example Two metabolites with T1=500ms (blue) and T1=250ms (red) Flip angle: 60° Signal proportional to M z TR=3000ms 01.04.20108IBT time MzMz
9
Institute for Biomedical Engineering T1 weighting: Example Two metabolites with T1=500ms (blue) and T1=250ms (red) Flip angle: 60° Signal proportional to M z TR=300ms 01.04.20109IBT time MzMz
10
Institute for Biomedical Engineering T1 weighting: Example Two metabolites with T1=500ms (blue) and T1=250ms (red) Flip angle: 60° Signal proportional to M z TR=100ms 01.04.201010IBT time MzMz
11
Institute for Biomedical Engineering Relevant parameter: Echo time (TE) = time between excitations and data acquisition Strong T2 weighting for long TE T2 / T2* weighting M xy t / ms TE short TE medium TE long
12
Institute for Biomedical Engineering Intensity scales with number of signal generating nuclei per volume element Keep influence of relaxation times small: Short TE -> small effect of T2 / T2* on signal Long TR -> small effect of T1 Proton density weighting
13
Institute for Biomedical Engineering IBT Functional MRI (fMRI)
14
Institute for Biomedical Engineering 14IBT Uses echo planar imaging (EPI) for fast acquisition of T2*-weighted images. Spatial resolution: 3 mm(standard 1.5 T scanner) < 200 μm(high-field systems) Sampling speed: 1 slice: 50-100 ms Problems: distortion and signal dropouts in certain regions sensitive to head motion of subjects during scanning Requires spatial pre-processing and statistical analysis. EPI (T2 * ) T1 dropout But what is it that makes T2* weighted images “functional”? Functional MRI (fMRI)
15
Institute for Biomedical Engineering The BOLD contrast Source: Jorge Jovicich, fMRIB Brief Introduction to fMRIfMRIB Brief Introduction to fMRI neural activity blood flow oxyhemoglobin T2* MR signal REST ACTIVITY
16
Institute for Biomedical Engineering The temporal properties of the BOLD signal sometimes shows initial undershoot peaks after 4-6 secs back to baseline after approx. 30 secs can vary between regions and subjects Brief Stimulus Undershoot Initial Undershoot Peak
17
Institute for Biomedical Engineering IBT MRI and Diffusion
18
Institute for Biomedical Engineering Brownian motion Molecules or atoms in fluids and gases move freely Collisions with other particles causes trembling movement Brownian motion: microscopic random walk of particles in fluids of gases (R. Brown 1827) Brownian motion depends on thermal energy, particle properties and fluid density
19
Institute for Biomedical Engineering Diffusion Diffusion: irreversible automatic mixing of fluids (or gases) due to Brownian motion Root mean square displacement depends on diffusion coefficient D and time (A. Einstein) Diffusion coefficient D affected by cell membranes, organelles, macromolecules (Le Bihan 1995)
20
Institute for Biomedical Engineering Anisotropy Restrictions on water diffusion usually without spherical symmetry anisotropic diffusion in biological tissue Diffusion tensor (=3x3-matrix) instead of diffusion coefficient accounts for anisotropic diffusion in 3D Principal diffusion direction: direction with largest diffusion coefficient Free Diffusion Restricted Diffusion rr rr rr
21
Institute for Biomedical Engineering Example: nerve fibre Diffusion perpendicular to fibre restricted Water diffusion indicates white matter organization
22
Institute for Biomedical Engineering Diffusion and MRI Diffusion leads to signal loss in MRI
23
Institute for Biomedical Engineering Diffusion gradients Signal attenuation depends on diffusion coefficient and gradient waveforms GE: sum of diffusion weighting gradients zero SE: diffusion weighting gradients have equal area Single shot techniques freeze out physical motion TETE 90° 180° diffusion gradient diffusion gradient EPI readout
24
Institute for Biomedical Engineering Diffusion weighted imaging DWI b-value (=b-factor) describes diffusion weighting analogous to TE in T2 weighted sequences b-value determined by diffusion weighting gradients (i.e. gradient form, strength, distance) signal b-factor [s/mm 2 ] 0 2004006008001000 S0: signal without diffusion weighting; D: diffusion coefficient in direction of gradient
25
Institute for Biomedical Engineering DTI Ellipsoid represents diffusion tensor Fibre structure via map of diffusion anisotropy: calculate fractional anisotropy (or relative anisotropy or volume ratio) P M MP S MS PS DWIs + Reference 3D ellipsoid ADC FA Color- coded FA
26
Institute for Biomedical Engineering Principal diffusion coefficient and vector: longest axis of diffusion tensor
27
Institute for Biomedical Engineering Brain structures via analysis of principle diffusion vectors Optic radiation Pons Middle cerebellar peduncle Corticospinal tract Corpus callosum Medulla Superior cerebellar peduncle Superior longitudinal fasciculus Medulla Tapetum
28
Institute for Biomedical Engineering IBT MR Angiography
29
Institute for Biomedical Engineering 01.04.201029IBT Blood flow Image Slice Saturation: apply 90° slice-selective pulse Gradient echo imaging: Don’t wait for gradient echo Bright signal from unsaturated spins in slice time Mz Stationary spins Inflowing spins saturation imaging MR Angiography
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.