1 ULTRASONIC WATER AND FLOW METERS
ELIS PLZEŇ a. s. PRODUCTS ULTRASONIC WATER AND FLOW METERS ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic ELIS PLZEŇ a. s., Luční 15, Plzeň, Cyech Republic

2 ULTRASONIC FLOW METERS
Intended for measurement of conductive and non- conductive clean liquids as water, demineralized water, fuel, oil, etc. Principal: transit time (measurement of time of flying ultrasonic beam from one to second transductor in direction of flow and in opposite direction of flow). The flow rate is calculated from difference of time. Flow meters are produced in single and dual beam version. They don’t have any moving parts They have min. pressure loses ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

3 ULTRASONIC FLOW METERS
Produced categories of ultrasonic flow meters: Battery supplied single or dual beam: FLOMIC FL5024, FL5044 (DN32 to DN200) FLOMIC FL5034, FL5054 (DN32 to DN300) FLOMIC FL3085 (DN200 to DN1200) FLOMIC FL3005 (DN200 to DN2000) for direct assembly into piping ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

4 ULTRASONIC FLOW METERS
Main powered single or dual beam: SONOELIS SE404X, SE406X (DN32 to DN300) SONOELIS SE401X, SE402X (DN200 to DN1200) SONOELIS SE804X, SE806X (DN200 to DN1200) for direct assembly in to piping ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

5 BATTERY POWERED ULTRASONIC WATER METERS
FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

6 BATTERY POWERED ULTRASONIC WATER METERS
FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) Certified according to MID (European metrology certificate) and OIML R49 Designed in observance of standard EN14154 Intended for measurement of clean water and substitution of mechanical water meters WOLTMAN type Intended for diagnostic of general condition of water network and water leakages in piping They can measure instantaneous flow rate in both direction, consumption of water, pressure They don’t have any moving parts They have very low pressure loses ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

7 BATTERY POWERED ULTRASONIC WATER METERS
FLOMIC FL5024 (single beam), FLOMIC FL5044 (dual beam) Nominal diameter: DN32 to DN200 (single beam), DN65 to DN200 (dual beam) Technical parameters FLOMIC FL5024 FLOMIC FL5044 Nominal diameter 32 40 50 65 80 100 125 150 200 Overload flow [m3/hr] 12,5 20 31,25 78,75 312,5 500 Permanent flow [m3/hr] 10 16 25 63 160 250 400 Transition flow [m3/hr] 0,32 0,512 0,8 1,28 2,016 3,2 5,12 8,0 12,8 0,64 1,0 1,6 2,5 4,0 6,4 Min. flow [m3/hr] 0,2 0,5 1,26 2,0 5,0 0,4 0,63 Pulse number [liters/pulse] ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

8 BATTERY POWERED ULTRASONIC WATER METERS
FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) Material of sensor: casting from cast iron Connection: flanges (EN, ANSI, JIS) Water pressure class: MAP16 Temperature class: T50 Flow-profile sensitivity class: U5 (FL5044), U10 (FL5024) – in front of meter D3 (FL5044), D5 (FL5024) – behind meter Pressure loss class: ∆P10 Climatic and mechanical class: B Electromagnetic environment: E1, E2 Display unit: single-line 8 character LC display Flow rate sampling period: 1 sec Protection class: IP68 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

9 BATTERY POWERED ULTRASONIC WATER METERS
FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) Power supply: Li battery 3,6 V/19Ah – live time 8 years Output: passive pulse output (U= 3 to 30V, I = 0,002 to 10mA, timp = 30ms) passive current output 4 to 20mA (U = 10 to 24 V) Optional equipment: bi-directional measurement (± passive pulse output) passive current output 4 to 20mA in combination of electrical contact for flow direction USB, RS232 or RS232 + USB converter GSM module FLODAT FD1.00 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

10 BATTERY POWERED ULTRASONIC WATER METERS
FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) BASIC DIMENSIONS and WEIGHT Diameter 32 40 50 65 80 100 125 150 200 L [mm] 260 300 350 S [mm] 140 145 155 160 165 180 190 205 Weight [kg] 4,5 7 10 11 15 17,5 22,5 26 36,5 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

11 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) 11 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

12 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) Intended for measurement of clean water They can measure instantaneous flow rate in both direction, consumption of water, pressure They don’t have any moving parts They have very low pressure loses 12 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

13 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL5034 (single beam), FLOMIC FL5054 (dual beam) Nominal diameter: DN32 to DN300 (single beam), DN40 to DN300 (dual beam) Technical parameters FL5034 FL5054 Nominal diameter 32 40 50 65 80 100 125 150 200 250 300 Overload flow [m3/hr] 20 31,25 78,75 312,5 500 787,5 1250 Permanent flow [m3/hr] 16 25 63 160 400 630 1000 Transition flow [m3/hr] 0,4 0,635 1,02 1,6 2,52 4,0 5,0 6,3 12,8 20,1 32,0 0,32 0,51 0,8 1,28 2,05 2,56 3,2 6,4 10,08 16,0 Min. flow [m3/hr] 0,25 0,397 1,0 1,587 2,54 3,17 3,97 8,0 12,6 20,0 0,2 0,5 2,0 10,0 Pulse number [liters/pulse] 10 13 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

14 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) Material of sensor: weldment (measuring part is made from ss-steel , flanges and cover from carbon steel) Connection: flanges (EN, ANSI, JIS) Water pressure class: MAP16, MAP40 Temperature class: T50 Flow-profile sensitivity class: U5 (FL5044), U10 (FL5024) – in front of meter D3 (FL5044), D5 (FL5024) – behind meter Pressure loss class: ∆P10 Climatic and mechanical class: B Electromagnetic environment: E1, E2 Display unit: single-line 8 character LC display 14 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

15 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) Flow rate sampling period: 1 sec Power supply: Li battery 3,6 V/19Ah – live time 8 years Protection class: IP68 Output: passive pulse output (U= 3 to 30V, I = 0,002 to 10mA, timp = 30ms) passive current output 4 to 20mA (U = 10 to 24V) Optional equipment: complete ss-sensor bi-directional measurement (± passive pulse output) passive current output 4 to 20mA in combination of electrical contact for flow direction USB, RS232 or RS232 + USB converter GSM module FLODAT FD1.00 15 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

16 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) BASIC DIMENSIONS and WEIGHT Diameter 32 40 50 65 80 100 125 150 200 250 300 L [mm] 360 450 S [mm] 175 180 185 190 210 225 235 255 280 305 Weight [kg] 1,6 MPa 18 19 20 29 46 59 Weight [kg] 4,0 MPa 10 12 13 16 21 22 38 71 85 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

17 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3085 (single beam) 17 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

18 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3085 (single beam) Intended for measurement of clean water in big dimensions Measurement of instantaneous flow rate in both direction and consumption of water Storage data They don’t have any moving parts They have very low pressure loses 18 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

19 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3085 (single beam) Nominal diameter: DN200 to DN1200 Material of sensor: weldment, material from carbon steel, painted Connection: flanges (EN, ANSI, JIS) Nominal pressure: PN6, PN10, PN16, PN40 Temperature of liquid: 0 to 150°C Ultrasonic transductors: 2 pcs of US2.1 (manufactured by ELIS PLZEŇ a. s.) Display unit: single-line 8 character LC display Power supply: Li-battery + 2 x Alkali batteries 9V, live time 4 years Transductors connection cable: max. 20m Accuracy: ±1% in range 1:20 19 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

20 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3085 (single beam) Flow rate sampling period: 1 sec Protection class: of electronic: IP65 Protection of sensor: IP54/IP68 Outputs: passive pulse output (U= 30V, I = 10mA) passive current output 4 to 20mA (U = 24V) Optional equipment: complete ss-sensor bi-directional measurement (± passive pulse output) passive current output 4 to 20mA in combination of electrical contact for flow direction USB, RS232 or RS232 + USB converter 20 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

21 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3085 (single beam) 21 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

22 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3005 (single beam) 22 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

23 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3005 (single beam) 23 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

24 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3005 (single beam) Intended for measurement of clean water on big piping Installation directly to existing piping Measurement of instantaneous flow rate in both direction and consumption of water Theoretical calibration after installation Storage data 24 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

25 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3005 (single beam) Nominal diameter: DN200 to DN2000 Nominal pressure: PN40 Temperature of liquid: 0 to 150°C Ultrasonic transductors: 2 pcs of US2.1 (manufactured by ELIS PLZEN a. s.) Display unit: single-line 8 character LC display Flow rate sampling period: 1 sec Power supply: Li-battery + 2 x Alkali batteries 9V, live time 4 years Transductors connection cable: max. 20m Protection class of electronic: IP65 Protection of sensor: IP54/IP68 25 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

26 BATTERY POWERED ULTRASONIC FLOW METERS
FLOMIC FL3005 (single beam) Output: passive pulse output (U= 3 to 30V, I = 10mA) passive current output 4 to 20mA, (U = 24V) communication interface RS232 Accuracy: ± 2% in range 1:20 Optional equipment: bi-directional measurement (± passive pulse output) passive current output 4 to 20mA in combination of electrical contact for flow direction USB, RS232 or RS232 + USB converter 26 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

27 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) 27 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

28 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) Intended for measurement of non conductive and conductive clean liquids as water, demineralized water, condensate, fuel, diesel, oil Measurement of instantaneous flow rate in both direction and consumption of water Measurement of mass flow and mass of water with connection of temperature sensor Pt100 They don’t have any moving parts They have very low pressure loses 28 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

29 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) Nominal diameter: DN32 to DN300 Nominal pressure: PN16, PN40 Measurement accuracy: ±1% for velocity of liquid v>0,5 m/s (SE404X) ±0,5% for velocity of liquid v>0,5 m/s (SE406X) Temperature of liquid: 0 to 150°C Ambient temperature: +5 to +55°C Display unit: alpha-numerical LCD unit, 2 lines, 16 characters each Power supply: 90 to 230V AC, 50 to 60Hz Protection class: electronics IP65, sensor IP67 29 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

30 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) Material of sensor: weldment (measuring part is made from ss-steel , flanges and cover from carbon steel) Flow-profile sensitivity class: U5 (SE406X), U10 (SE404X) – in front of meter D3 (SE406X), D5 (SE404X) – behind meter Outputs: pulse output (selected 0.1 to 1,000 l/pulse) Frequency output, selected 0 t 1,000 Hz or 10kHz Relay type 24V AC/0,1A 30 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

31 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) Optional equipment: communication line RS485 extended temperature range for sensors: - 20° to 180°C Current output (0)4 to 20mA Mass-flow rate measurement capability Flow rate measurement in two directions sensor protection class IP68 100 m (max.) transductors connection cable 31 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

32 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) METER VERSION, CONFIGURATION and TYPE DESIGNATION VERSION COMPACT REMOTE CONFIGURATION Economic Standard Comfort SINGLE-BEAM SENSOR SE4040 SE4042 SE4044 SE4041 SE4043 SE4045 DUAL-BEAM SENSOR SE4060 SE4062 SE4064 SE4061 SE4063 SE4065 32 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

33 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) 33 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

34 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) 34 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

35 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) Intended for measurement of non conductive and conductive clean liquids as water, demineralized water Measurement of instantaneous flow rate in both direction and consumption of water Measurement of mass flow and mass of water with connection of temperature sensor Pt100 They don’t have any moving parts They have very low pressure loses 35 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

36 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) Nominal diameter: DN200 to DN1200 Nominal pressure: PN16, PN40 Measurement accuracy: ±1% for velocity of liquid v>0,5 m/s (SE401X) ±0,5% for velocity of liquid v>0,5 m/s (SE402X) Temperature of liquid: 0 to 150°C Ambient temperature: +5 to +55°C Display unit: alpha-numerical LCD unit, 2 lines, 16 characters each Power supply: 90 to 230V AC, 50 to 60Hz Protection class: electronics IP65, sensor IP54 36 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

37 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) Material of sensor: weldment (material of measuring part flanges from carbon steel) Flow-profile sensitivity class: U5 (SE402X), U10 (SE401X) – in front of meter D3 (SE402X), D5 (SE401X) – behind meter Outputs: pulse output (selected 0.1 to 1,000 l/pulse) Frequency output, selected 0 t 1,000 Hz or 10kHz Relay type 24VAC/0,1A 37 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

38 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) Optional equipment: communication line RS485 extended temperature range for sensors: ° to 180°C Current output (0)4 to 20mA Mass-flow rate measurement capability Flow rate measurement in two directions sensor protection class IP68 100 m (max.) transductors connection cable 38 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

39 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) METER VERSION, CONFIGURATION and TYPE DESIGNATION VERSION REMOTE CONFIGURATION ECONOMIC STANDARD COMFORT SINGLE-BEAM SENSOR SE4011 SE4013 SE4015 DUAL-BEAM SENSOR SE4021 SE4023 SE4025 39 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

40 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) 40 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

41 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) 41 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

42 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) 42 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

43 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) Intended for measurement of clean water on big piping Installation directly to existing piping Measurement of instantaneous flow rate in both direction and consumption of water Measurement of mass flow and mass of water with connection of temperature sensor Pt100 Theoretical calibration after installation 43 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

44 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) Nominal diameter: DN200 to DN1200 Nominal pressure: PN40 Temperature of liquid: 0° to 150°C Ultrasonic transductors: 2 pcs of US2.1 (manufactured by ELIS PLZEŇ a. s.) Display unit: single-line 8 character LC display Power supply: 90 to 250VAC, 50 to 60Hz Transductors connection cable: max. 100m Protection class of electronic: IP65 Protection of sensor: IP54 44 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

45 MAIN POWERED ULTRASONIC FLOW METERS
SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) Output: passive pulse output (U= 3 to 30V, I = 10mA) passive current output 4 to 20mA, (U = 24V) communication interface RS232 Accuracy: ± 2% in range 1:20 Optional equipment: communication line RS485 extended temperature range for sensors -20° to 180°C Current output (0) 4 to 20mA Mass-flow rate measurement capability Flow rate measurement in two directions sensor protection class IP68 100 m (max.) transductors connection cable 45 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic

46 Thank you for your attention
ELIS PLZEŇ a. s. Luční Plzeň Czech Republic Phone: Fax: 46 ELIS PLZEŇ a. s., Luční 15, Plzeň, Czech Republic