Download presentation
Presentation is loading. Please wait.
Published byMarcel Wolman Modified over 9 years ago
1
ARCs cut definition for TEC modules Javier Fernandez Menendez Institut für Experimentelle Kernphysik Karlsruhe University TEC meeting 14 th July 2004
2
Javier Fernandez (IEKP/UniKa)2 ARCs TEC Data on the web R1: 31N + 19S from Hamburg R2: 21S + 26N from Wien (problem in 2 APVs) R3: 31 from Ka + 23 from Ham (x-check) R4: 26 modules from Zurich R5: not enough statistics yet in community… R6: 23 from Aachen R7: 24 from Strasbourg Total: ~230 modules = ~2.5Gb of data in files
3
Javier Fernandez (IEKP/UniKa)3 What cuts can be defined? PinholeOpen Healthy Noisy No statistical criteria here: tagged as bad channels anyway in DB Statistical and graphical criteria Not use APV border channels for cuts definition
4
Javier Fernandez (IEKP/UniKa)4 Methodology Noise for all modules from one geometry in one single APV mode
5
Javier Fernandez (IEKP/UniKa)5 Methodology: an example Border Channels: 1,2, 128, 129, 255, 256, 384, 385, 511, 512 Next to border channels: 127, 130, 254, 258, 383, 386 0.9 (~4 1.3 (~4 Symmetric 4 cut from mean for healthy region definition
6
Javier Fernandez (IEKP/UniKa)6 Final result of cuts 1.3 (~4 ) 0.9 (~4 ) Noisy channels perfectly tagged!!! Still room for fluctuations (4 = 99.95% probability) Healthy region
7
Javier Fernandez (IEKP/UniKa)7 Summary of noise 4 cuts ModeR1R2R3R4R6R7 Mean1.01.021.111.131.331.44 0.050.070.050.040.050.06 Plow0.800.750.900.951.101.20 Phigh1.201.30 1.551.70 Mean1.371.401.541.591.701.80 0.050.080.070.050.06 Dlow1.151.101.251.401.451.55 Dhigh1.601.701.851.801.952.05 Stereo and Normal R1 show ~equal noise values Noise and cuts increase with R#
8
Javier Fernandez (IEKP/UniKa)8 R2 modules problem Lower average noise in central APVs Effect not seen in other geometries with 6 APVs (R1 and R5)
9
Javier Fernandez (IEKP/UniKa)9 It makes distribution not gaussian Central APVs Not-central APVs contribution
10
Javier Fernandez (IEKP/UniKa)10 Not an apparent Wien test problem PIO PIOn DIO DIOn Wien Karlsruhe R2 Module 26690
11
Javier Fernandez (IEKP/UniKa)11 Not an apparent Wien test problem PIOPIOn DIO DIOn Wien Aachen R2 Module 26697
12
Javier Fernandez (IEKP/UniKa)12 Conclusions There is a clear behavior difference between: channels at the borders of the APV and channels next to channel border Noise cuts defined/confirmed for TEC mods. –Program mainAnalyzer (in DefAna package) allows to redefine them in an easy way if needed and do extensive module analysis/comparisons Noise ~equal in stereo and normal modules Statistical gaussian method: first iteration 4 symmetric criterium maybe too tight ? But 5 could be too loose in some cases…
Similar presentations
© 2025 SlidePlayer.com. Inc.