Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 SET x10/X30 On Board Data Collection On Board Data Collection using the COORD Program sokkia.

Similar presentations


Presentation on theme: "1 SET x10/X30 On Board Data Collection On Board Data Collection using the COORD Program sokkia."— Presentation transcript:

1 1 SET x10/X30 On Board Data Collection On Board Data Collection using the COORD Program sokkia

2 sokkia 2 On Board Topo Recommendations and Requirements Recommendations and Requirements SF14 Keypad is recommendedSF14 Keypad is recommended A CP7 Tubular Compass is requiredA CP7 Tubular Compass is required HI TapeHI Tape Note padNote pad This exercise assumes that there is no project control and we are starting a new job.This exercise assumes that there is no project control and we are starting a new job.

3 sokkia 3 On Board Topo Plumb and Level Instrument over a new control marker. Plumb and Level Instrument over a new control marker. You should read the first few sections of the manual to familiarize yourself with the basic operations of the instrument.You should read the first few sections of the manual to familiarize yourself with the basic operations of the instrument. Install the CP7 Tubular CompassInstall the CP7 Tubular Compass Release the needle by twisting the silver nob atop the compass. Release the needle by twisting the silver nob atop the compass. Rotate the instrument until the needle splits the hash marks Rotate the instrument until the needle splits the hash marks

4 sokkia 4 On Board Topo When the needle is properly aligned lock the Horizontal Motion When the needle is properly aligned lock the Horizontal Motion Select F3 0SET.Select F3 0SET. Now the encoders on the instrument are zero at approximately magnetic north.Now the encoders on the instrument are zero at approximately magnetic north. We have now oriented the instrument and have made it ready for Topo. We have now oriented the instrument and have made it ready for Topo.

5 sokkia 5 On Board Topo Selecting and Editing a Job Name Selecting and Editing a Job Name Select the ESC key from the key pad or instrument.Select the ESC key from the key pad or instrument. Select F3 MEMSelect F3 MEM Select JOB Select JOB Use your arrows to highlight a JOB and then select EDIT. Use your arrows to highlight a JOB and then select EDIT. Edit the name to reflect the desired designation.Edit the name to reflect the desired designation. Ensure that the Coord Job is the same as the one selected.Ensure that the Coord Job is the same as the one selected.

6 sokkia 6 On Board Topo Select the Enter key when complete. Select the Enter key when complete. Use the ESC key to get back to the Status Screen. Use the ESC key to get back to the Status Screen.

7 sokkia 7 On Board Topo Select F1 MEAS Select F1 MEAS Rotate the instrument to the BS Point and sight it on the target. Rotate the instrument to the BS Point and sight it on the target. Notice and jot down the HAR value. This number will be used later in Station Orientation.Notice and jot down the HAR value. This number will be used later in Station Orientation.

8 sokkia 8 On Board Topo Tip Tip Measure the Instrument and Prism heights before beginning the data collection process. Jot these down along with the HAR value.Measure the Instrument and Prism heights before beginning the data collection process. Jot these down along with the HAR value.

9 sokkia 9 On Board Topo Data Collection Data Collection Select F4 Coord (on page 1)Select F4 Coord (on page 1) Station Orientation Station Orientation STN Coordinate (where the instrument is located) STN Coordinate (where the instrument is located) F3 EDITF3 EDIT Complete the required fields. Complete the required fields. N, E, Z, Inst H and Tgt H. N, E, Z, Inst H and Tgt H. OK to Accept OK to Accept

10 sokkia 10 On Board Topo F2 REC F2 REC Edit the point Number if required.Edit the point Number if required. Edit the description if required.Edit the description if required. OK OK

11 sokkia 11 On Board Topo Orientation (SET H ANGLE) Orientation (SET H ANGLE) Highlight and Select SET H ANGLE Highlight and Select SET H ANGLE Enter the value you wrote down earlier.Enter the value you wrote down earlier. ENTERENTER ESCESC Prepare for BS Measurement by checking the prism for proper installation and that it is plumb over the second new reference point. Prepare for BS Measurement by checking the prism for proper installation and that it is plumb over the second new reference point.

12 sokkia 12 On Board Topo Sight The BS Prism Sight The BS Prism Highlight and select OBSERVATIONHighlight and select OBSERVATION ENTERENTER After the measurement is complete: After the measurement is complete: RECREC Edit Code field as required. Edit Code field as required. Highlight DESC and select EDIT. Select ENTER when complete.Highlight DESC and select EDIT. Select ENTER when complete. Then OK.Then OK.

13 sokkia 13 On Board Topo Select F1 OBS for the next measurement and follow the steps for editing the DESC and HTs. Select F1 OBS for the next measurement and follow the steps for editing the DESC and HTs. Repeat this process until you are done. Repeat this process until you are done.

14 sokkia 14 On Board Topo DATA TRANSFER DATA TRANSFER Start Carlson XML on your DesktopStart Carlson XML on your Desktop Turn Instrument ON.Turn Instrument ON. Select MEM from the Status ScreenSelect MEM from the Status Screen Connect the DOC 27 Download Cable to the instrument and the PC. Connect the DOC 27 Download Cable to the instrument and the PC.

15 sokkia 15 On Board Topo Set up the comm link;Set up the comm link; Carlson XML Carlson XML Select Tools|Data Collectors| Sokkia SDRSelect Tools|Data Collectors| Sokkia SDR Instrument Instrument Select Comms OutputSelect Comms Output Highlight the job, select Enter. The record on the far right will now indicate OUT. Select OK then the instrument will offer the type of file select SDR and then hit ENTER.

16 sokkia 16 On Board Topo The only bumps in the road you may experience with data transfer are comm settings and time outs. The only bumps in the road you may experience with data transfer are comm settings and time outs. Comm settings Comm settings Check them and make sure these are mirrored between the PC and Instrument.Check them and make sure these are mirrored between the PC and Instrument. Time Out Time Out Timing is everything. Try and time the final ENTER on the Instrument as close as possible to the keystrokes required by Carlson.Timing is everything. Try and time the final ENTER on the Instrument as close as possible to the keystrokes required by Carlson.

17 sokkia 17 On Board Topo Questions? Questions?


Download ppt "1 SET x10/X30 On Board Data Collection On Board Data Collection using the COORD Program sokkia."

Similar presentations