Grating Phase-Contrast Imaging for Diagnostic of High Energy Density Plasmas D. Stutman, M.P. Valdivia, M. Finkenthal Department of Physics & Astronomy.

Similar presentations


Presentation on theme: "Grating Phase-Contrast Imaging for Diagnostic of High Energy Density Plasmas D. Stutman, M.P. Valdivia, M. Finkenthal Department of Physics & Astronomy."— Presentation transcript:

1 Grating Phase-Contrast Imaging for Diagnostic of High Energy Density Plasmas D. Stutman, M.P. Valdivia, M. Finkenthal Department of Physics & Astronomy Johns Hopkins University, USA Work supported by US DoE/NNSA Grant DENA0001B35 Presented at the 2014 International Workshop on X-ray and Neutron Phase Imaging with Gratings Garmisch-Partenkirchen, January 22 2014, Germany

2 High Energy Density Plasmas are extreme state of matter ICF ignition 10 8 10 6 10 4 10 20 10 22 10 26 Temperature (K) Electron density (cm -3 ) Solar core Planetary cores ICF compression Solids 10 24 Energy density> 10 5 J/cm -3 (p>1 Mbar ) 10 2

3 HEDP in Inertial Confinement Fusion D-T fuel 300 TW laser power for 4 ns 6mm Be shell 200µm 600 g/cm 3 10 8 K IgnitionNuclear burn (100x energy gain) CompressionAblation

4 Density is fundamental plasma parameter in HEDP Koch et al JAP 2009 2 10 24 1 10 24 2 10 24 1 10 24 Electron density N at mid-compression in ICF (cm-3) 00.61.2 R (mm) 0.530.540.550.56 10-1000 µm scales 10 µm resolution Density -> Confinement Gradient-> Stability

5 Capsule mixing (HYDRA computation) Density (g/cm -3 ) Burn possible Burn not possible Clark et al LLNL report 2011 Plasma turbulence makes gradients also on the µm scale 50 µm

6 X-ray radiography for density diagnostic in HEDP 10 µm pinhole Target plasma Gated X-ray detector Backlighter laser 100 cm Main laser 2 cm Pinhole backlighters for <10 keV radiography Hot V-Ge plasma

7 Micro-foil backlighters for 20-75 keV radiography High-Z foil 10µm K-a 100ps/1 kJ (1 petawatt) laser Poor attenuation contrast in low-Z plasmas Density gradient hard to diagnose

8 Refraction angles in the 100 µrad range expected in HEDP Koch et al JAP 2009 Refraction angles for 8 keV photons in ICF (µrad) R (mm) 0.530.540.550.56 200 100 0 -100

9 Talbot-Lau radiography has great potential for HEDP Attenuation radiograph T-L Moiré deflectometry 3 mm Be rod M=25x 25kVp Mo tube 1 mm Much more sensitive than attenuation Direct density gradient diagnostic

10 How to implement Talbot-Lau interferometry in HEDP Small G0 ≤ 2.5 µm (A=G0/P≈100 µrad) High Talbot magnification, Talbot order Moiré deflectometry with ≥10% contrast for 10s of µm fringe period at object In-situ phase background Removable X-ray tube G0 Detector P≈2.5 cm shield G1 G2

11 Good fringe contrast achieved at high Talbot magnification G0=2.4 µm, G1=3.8 µm, G2=10 µm (M T =5.2) E~17 keV (Mo anode 25 kVp), A=80 µrad M.P. Valdivia et al JAP 2013 m=3 100 µm fringe period at object SNR fringe period limit of ~30 µm

12 Accurate, high resolution density profiles Remarkable accuracy for angles << interferometer angular width Density gradient in 3 mm Be rod Mo anode 25 kVp, M=20x Areal density profile

13 Simultaneous density gradient and attenuation maps Refraction Attenuation Simultaneous density and Z eff diagnostic 1.5 mm Al rod, 17 keV, M=20x

14 1.5 mm Plastic doped with micro-particles Scatter imaging also works Scatter image µ-turbulence diagnostic without µm spatial resolution T-L Moiré deflectometry at 8 keV also very encouraging

15 High magnification interferometry below 10 keV Free-standing phase grating Au grating on membrane MICROWORKS INC 40 mm Early ICF stages, smaller HEDP experiments

16 >30% fringe contrast with free-standing grating Moiré deflectometry at 8 keV (Cu anode) Fruit-fly Wax drop Be rod

17 Pinhole aperture (µm) Will G0 survive long enough to produce useful images? Pinhole closure experiments Reighard et al RSI 2008 1 GW/cm 2 soft X-rays on G0 Few ns lifetime for G0 on Si substrate + photoresist

18 Alternate G0 solutions explored Micro-periodic mirror Micro-layered backlighter 1 µm 100 ps laser

19 SUMMARY Talbot-Lau method has great potential for HEDP diagnostic G0 survival, 2-D gratings, phase-retrieval without Moiré fringes High M interferometry for biomedical, material applications

20 Moiré deflectometry demonstrated in low density plasmas Grava et al 2008 Moiré deflectometry of 10 20 cm -3 plasma jet using soft X-ray laser

21 Resolution improves with smaller source size 80 micron 40 micron 10 micron M O = 8-25 W eff = 80 µrad 58 µm 30 µm 8 µm M=20