Download presentation
1
Thermal Imaging Cameras and Their Uses
2
Objectives Student will know each thermal imagers operation and features Students will understand the basic mechanics of thermal images Student will understand applications
3
Countryside Cameras 4131 Bullard T3 Max 4110 MSA Evolution 5200
4
Camera Features Bullard T3 Max Microbolometer Core EI mode
Will Shutter EI mode Relative Heat Indicator Electronic Thermal Throttle Super Red Hot Feature
5
Camera Features MSA Evolution 5000 and 5200 Microbolometer Core
Will Shutter Optional quick temp indicator with digital measurement Low sensitivity mode indicator Shutter indicator Heat seeker plus indicator Over temperature indicator
6
Bullard T3, MSA 5000 & 5200 Shutter The unit has an automated shutter used to calibrate or change sensitivity Fires about every seconds depending on environment When it fires screen will freeze for 1-2 seconds
7
Bullard T3 Max EI mode 2 levels of operation Normal- low temp scenes
EI –elevated temperatures Automatically switch when object viewed >300 degree F Will shutter between modes
8
Low Sensitivity Mode Indicator
MSA Evolution 5000 and 5200 Low Sensitivity Mode Indicator Will automatically switch when TIC senses environment about 300 degrees F “L” appears on lower right corner of screen
9
Relative Heat Indicator
Bullard T3 Max Relative Heat Indicator Bar graph on right side of screen Temp accuracy decreases as distant from object increases Accuracy of indicator dependent on; Distance from object Emissivity (ability to radiate heat)
10
Optional quick temp indicator with digital measurement
MSA Evolution 5000 and 5200 Optional quick temp indicator with digital measurement Similar to relative heat indicator Temperatures from 32 degrees F to 300 degrees in high sensitivity mode and 32 degrees to 1000 degrees in low sensitivity mode Digital value only displays approximate value
11
Relative Heat Indicator
Bullard T3 Max Relative Heat Indicator
12
Bullard T3 Max Thermal Throttle
Enables firefighters to optimize the scene with the touch of a button Pinpointing hot spots during overhaul, searching for overheated electrical equipment, and distinguishing hotter objects from cooler ones Paints the hottest objects in the scene blue, leaving other hot objects white
13
Thermal Throttle
14
Bullard T3 Max Thermal Throttle
For firefighter safety, the ETT blue feature does not operate when the T3 MAX detects it should be operating the Super Red Hot feature
15
Bullard T3 Max Super Red Hot Feature
Heat levels are identified by color Starting at 500 degrees, heated objects are yellow transitioning to orange then red Provides enhanced visual awareness
16
Optional Heat Seeker PLUS Indicator
MSA Evolution 5000 and 5200 Optional Heat Seeker PLUS Indicator Graduated color (yellow to orange to red) of portions of a scheme that are above 275°F(135°C)-yellow, 297°F-red, in High Sensitivity, or 842°F-yellow, 914°F-red, in Low Sensitivity mode
17
Over Temperature Warning
MSA Evolution 5000 and 5200 Over Temperature Warning Lower left below screen Flashing red indicates exceeded recommended operational thermal limits Tests on the Evolution TIC’s indicate that it will provide an acceptable image when subjected to an ambient temperature or approx. 248 degrees for about ten minutes. Exposure to conditions exceeding these will result in deterioration and loss of image.
18
Emitters Active Passive Direct Produce own heat Human
Object that can be heated or cooled Does not produce own heat Direct Source of heat Sun, fire
19
Active emitter exercise
20
Passive Emitter Exercise
21
What a TIC will do Allows you to “see” the area that you are working in. Dramatically cuts down the time for a primary search. Narrows down the search area. Locate the seat of the fire quicker. Assist with size-up.
22
What a TIC Won’t Do Won’t “see” through water, windows or windshields.
Infrared wavelengths won’t pass through those types of mediums.
23
What a TIC Won’t Do Won’t “see” through furniture.
Won’t “see” through walls, floors, etc. It will “see” heat transferred through walls.
24
Fire in Wall
25
Practical Applications
Size-up RIT Light ballast, electrical motor/appliance issues ID spaces quickly: attics, walls, cocklofts, utility chases, roof profile Victim ejections, limb searches Overhaul Extension searches Chimney fire Search
26
Practical Applications
Roof vent location “See” the truss system Directly over the fire Cut-man can see the area in need of cutting Wildland/Brush Haz Mat incidents Top of water searching
27
Size Up – Fire location
28
Size Up – Fire location
29
RIT SCBA bottles and fittings will appear dark
Reflective trim on gear will contrast with fire resistive material Firefighters will not be located in the traditional locations that civilian victims are found Look for signs of firefighter presence (marked thermal layers, hose lines,cold/wet spots, etc.)
30
RIT SCBA bottles and fittings will appear dark while straps and padding will absorb heat
31
RIT “Reflective trim on gear will contrast with fire resistive material”
32
Electrical Outlets Obtain Thermal Image Identify problem outlet
Use traditional means to check for heat Obtain Thermal Image Identify problem outlet
33
Electrical Outlets Or if you see this starting to occur
Monitor area and ensure thermal outline decreases Decreases causing unnecessary damage When is it time to open up?? Anytime you want to.. Or if you see this starting to occur
34
ID Spaces Parapet height? Construction Type?
35
SEARCHING W/ TIC Interior searches should be approached with safety in mind. Do not abandon current safety practices Teams Patterns Organization Communications USE OTHER SENSES AS WELL Stay low REALITY CHECKS Take non-camera views- every 30 seconds
36
Six-sided Approach First (UP) Second (DOWN) THIRD, FOURTH , FIFTH
Ceiling where heat is, heated gasses, extension or collapse areas. Where is it moving? Second (DOWN) Floor. No holes, make sure you are not directly over the fire or other hazards. THIRD, FOURTH , FIFTH Right, Center, Left Look for hazards, egress SIXTH (BEHIND) Hazards, changing conditions Egress routes
37
Convection Waves
38
SEARCHES w/ TIC Camera Directed Search TIC operator makes a room
Gets 6 sided view “DIRECTS” search crews through space Stays at the door or egress point for when camera malfunctions
39
SEARCHES w/ TIC Camera Led Search TIC operator makes a room
Gets 6 sided view Camera operator with the TIC searches the space Unsighted crews stay at the door or egress point for when camera malfunctions
40
SEARCHES w/ TIC Point to Point Accelerates searches
Does not search areas he/she can see are clear When in doubt, search Utilized in conjunction with other search techniques
41
SEARCHES w/ TIC TIPS Review where you have been
Check for changing conditions Communicate often and clearly Establish landmarks, window sill tops, door jambs to evaluate thermal layer -Make one if necessary DO NOT forget the basic fundamentals of proper searching Reality checks often Scan shoulder to shoulder Let a searcher see the area prior to searching
42
SEARCHES w/ TIC TIPS TICS can fail TICS WILL FAIL
Cannot see through water, glass Depth perception is altered NOT intrinsically safe Glass or smooth surfaces will reflect an image Scan horizontal not vertical
43
Ventilation Use TIC to find ventilation points Vent over seat of fire
See” the truss system Cut-man can see the area in need of cutting
44
Overhaul Use thermal throttle Overhaul hottest areas
45
Checking for Extension
46
TACTICAL CONSIDERATIONS
Three main things we are looking for Life Safety Occupants, down fire fighters Fire Conditions Thermal Layering Convected heat and fire gasses Fire source Structural Conditions Structural integrity
47
Hazmat
48
Wildland / Brush Fires Locate hotspots faster
Better application of water Save on valuable resources
49
Water Rescue Look for shape as well as heat
50
Common Mistakes Made Neglecting the physical search
Relying SOLEY on the camera TIC operator strays from rest of crew Crews forget basics Leave walls, hose lines Communication Standing up in thermal layer Crews now WALK, or worse, RUN through buildings
51
Common Mistakes Made Crews miss exits Manpower limitations
Not clearing condensation off of lens and germanium Forgetting that the TI has no peripheral vision Missed holes in floors Water on floor will look like a hole
52
Just Another TOOL in the BOX
53
References Bob Pugh, Brian Lee and Bob Hnatko of the Chesapeake Fire Department Deepwater Fools Bullard MSA
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.