Product Overview
2
ACCESS DEVICES
3
BladelessPyramidalShieldedHasson Ports
4
THREADED CANNULAE Rotate Clockwise to Insert Rotate Counter-Clockwise to Remove Beveled and Angled Distal Tip- For less insertion force and better visualization CO2 Port 45° angle to reduce CO2 tubing kinking Slide Valve Located on winged handle Red – Closed Green – Open 70 / 100 lengths
5
Threaded Cannulae
6
Smooth Cannulae Beveled and Angled Distal Tip - For less insertion force and better visualization Clear – for easy specimen retrieval CO2 Port 45° angle to reduce CO2 tubing kinking Slide Valve Located on winged handle Red – Closed Green – Open Available sizes 5mm,7/8mm, 10mm, 12mm, 15mm Sizes are stamped on Cannula Body Available lengths 70mm, 100mm,150mm
7
BLADELESS TROCARS
9
Bladeless Tip Trocar Allows for visualization during insertion Distinctive engineered visual tip Separates and dissects abdominal wall Available sizes -5mm -7/8 mm -10mm -12mm -15mm Available length 70mm, 100mm 150mm
10
Unique Features Smaller wound defect size than most trocar products Less insertion force Less incidence of internal injuries Greater visualization of tissue layers w/scope use Separates and dissects abdominal wall Smooth insertion reducing pre- peritoneal tenting Less insertion force Ergonomic handle – easy grip for insertion Scope seal 5– 10mm
11
Bladeless Trocar Configurations Part NumberDescriptionUOM 200-005-0505mm x 70mm Bladeless Trocar5 200-005-1505mm x 100mm Bladeless Trocar5 200-005-2505mm x 150mm Bladeless Trocar5 200-008-1507/8mm x 100mm Bladeless Trocar5 200-010-15010mm x 100mm Bladeless Trocar5 200-010-25010mm x 150mm Bladeless Trocar5 200-012-15012mm x 100mm Bladeless Trocar5 200-012-25012mm x 150mm Bladeless Trocar5 200-015-15015mm x 100mm Bladeless Trocar5 200-015-25015mm x 150mm Bladeless Trocar5 200-005-0515mm x 70mm Bladeless Trocar and One Cannula (Threaded)5 200-005-1515mm x 100mm Bladeless Trocar and One Cannula (Threaded)5 200-010-15110mm x 100mm Bladeless Trocar and One Cannula (Threaded)5 200-012-15112mm x 100mm Bladeless Trocar and One Cannula (Threaded)5 200-005-0525mm x 70mm Bladeless Trocar and Two Cannulae (Threaded)5 200-005-1525mm x 100mm Bladeless Trocar and Two Cannulae (Threaded)5 200-010-15210mm x 100mm Bladeless Trocar and Two Cannulae (Threaded)5 200-012-15212mm x 100mm Bladeless Trocar and Two Cannulae (Threaded)5
12
Bladeless Trocar Configurations (continued) Part NumberDescriptionUOM 200-005-0515mm x 70mm Bladeless Trocar and One Cannula (Smooth)5 200-105-1515mm x 100mm Bladeless Trocar and One Cannula (Smooth)5 200-105-2515mm x 150mm Bladeless Trocar and One Cannula (Smooth)5 200-108-1517/8mm x 100mm Bladeless Trocar and One Cannula (Smooth)5 200-110-15110mm x 100mm Bladeless Trocar and One Cannula (Smooth)5 200-110-25110mm x 150mm Bladeless Trocar and One Cannula (Smooth)5 200-112-15112mm x 100mm Bladeless Trocar and One Cannula (Smooth)5 200-112-25112mm x 150mm Bladeless Trocar and One Cannula (Smooth)5 200-115-15115mm x 100mm Bladeless Trocar and One Cannula (Smooth)5 200-115-25115mm x 150mm Bladeless Trocar and One Cannula (Smooth)5 200-105-0525mm x 70mm Bladeless Trocar and Two Cannulae (Smooth)5 200-105-1525mm x 100mm Bladeless Trocar and Two Cannulae (Smooth)5 200-110-15210mm x 100mm Bladeless Trocar and Two Cannulae (Smooth)5 200-112-15212mm x 100mm Bladeless Trocar and Two Cannulae (Smooth)5
13
SHIELDED TIP TROCAR
14
Shielded Tip Trocar Wedge Tip Design Minimizes defect size Maintains low insertion force Point is sharp – Sides are dull Spring Loaded Shield No locking mechanism in case of need to re- enter the cavity Color Coded for Size Differentiation Orange – 5mm Green – 10mm Purple – 12mm
15
Shielded Trocar Configurations Part NumberDescriptionUOM 100-005-0905mm x 70mm Shielded Tip Trocar10 100-005-1905mm x 100mm Shielded Tip Trocar10 100-010-09010mm x 100mm Shielded Tip Trocar10 100-012-09012mm x 100mm Shielded Tip Trocar10 100-005-0915mm x 70mm Shielded Tip Trocar and One Cannula (Threaded)5 100-005-1915mm x 100mm Shielded Tip Trocar and One Cannula (Threaded)5 100-010-191 10mm x 100mm Shielded Tip Trocar and One Cannula (Threaded)5 100-012-191 12mm x 100mm Shielded Tip Trocar and One Cannula (Threaded)5 100-005-0925mm x 70mm Shielded Tip Trocar and Two Cannulae (Threaded)5 100-005-192 5mm x 100mm Shielded Tip Trocar and Two Cannulae (Threaded)5 100-010-19210mm x 100mm Shielded Trocar and Two Cannulae (Threaded)5
16
PYRAMIDAL TIP TROCAR Very sharp pyramidal point Ease of insertion Less tissue trauma with straight stick – do not twist Palm piece has comfortable feel Easy to handle
17
PYRAMIDAL TROCAR CONFIGURATIONS Part NumberDescriptionUOM 100-005-0005mm x 70mm Pyramidal Tip Trocar10 100-005-1005mm x 100mm Pyramidal Tip Trocar10 100-005-001 5mm x 70mm Pyramidal Tip Trocar and One Cannula (Threaded)5 100-005-101 5mm x 100mm Pyramidal Tip Trocar and One Cannula (Threaded)5 100-005-002 5mm x 70mm Pyramidal Tip Trocar and Two Cannulae (Threaded)5 100-005-102 5mm x 100mm Pyramidal Tip Trocar and Two Cannulae (Threaded)5 100-105-001 5mm x 70mm Pyramidal Tip Trocar and One Cannula (Smooth)5 100-105-101 5mm x 100mm Pyramidal Tip Trocar and One Cannula (Smooth)5 100-105-002 5mm x 70mm Pyramidal Tip Trocar and Two Cannulae (Smooth)5 100-105-102 5mm x 100mm Pyramidal Tip Trocar and Two Cannulae (Smooth)5
18
Blunt Port (Hasson)
20
Blunt Port Suture Anchoring Device Malleable silicone Reduces defect size Makes a better seal Adjustable for precise depth insertion Available size 12mm 45º angle anchors for easy wrap Suture grooves vs. wheels for better fixation
21
Hasson/Blunt Port Configurations Part NumberDescriptionUOM Hasson / Blunt Tip 400-012-130 10-12mm x 110mm Blunt tip Obturator w/ Suture Anchoring Device5 400-012-131 12mm x 100mm Blunt tip Obturator and Cannula w/ Suture Anchoring Device5
22
Reducer Valve 5mm7/8mm10mm12mm15mm 5mm baseball cap 7/8mm to 15mm Reducer Valve (For instruments 5mm to 10mm)
23
Reducer Valves All 5mm cannula have the same baseball cap valve (single tab) Easily removed – Easy grip tab Plug reducer value (double tab) can be used with all 3mm- 5mm instruments in conjunction with universal valve All 7/8mm – 15mm cannula have the same Universal Valve Fits instruments from 5mm – 15mm without losing pneumoperitoneum Air tight – dual seal technology Bumps on inner/outer distal end of primary valve to reduce drag Can be easily removed from cannula for specimen retrieval
24
Trocar In-Service Techniques
25
VERESS NEEDLE
26
Spring mechanism Easy to use No valve adaptor needed Available sizes 120mm 150mm
27
VERESS NEEDLE ORDERING INFORMATION Part NumberDescriptionUOM 130-120-001 120 mm VERESS NEEDLE20 130-150-001150 mm VERESS NEEDLE20
28
Laparoscopic Instrumentation
29
Reusable Manual Instrumentation Mono-polar Bi-polar
30
Reusable Monopolar Instruments
31
Reusable Mono-Polar Modular system –3 Components Handle Insulated Shaft Insert INSULATED SHAFTINSERT Sterilization –Autoclave –EtO
32
Advantages of Reusable Mono-Polar Easy assembly Easy cleaning Lumen brush Components apart Insert jaws open Handle open Inserts provide excellent conductivity
33
Advantages of the GENICON Mono-Polar Variety of handles Rotates 360 degrees Comfortable and Light-weight One-Piece vs. Modular System Two Components Three Components
34
Reusable Laparoscopic Mono-Polar Instrumentation Handles Rotating Insulated Handle with HF Connector Rotating Insulated Handle with HF Connector and switchable ratchet Rotating Insulated Handle with HF Connector and ratchet Axial Metal Handle with Ratchet
35
Handle-to-Insert Harmonization Scissors Free-moving Graspers Ratching or Switchable Ratchet Dissectors Free-moving Needle Holders Axial
36
HANDLES: –Free-Moving, Standard Ratchet, Switchable Ratchet, Axial INSERTS: –Graspers, Scissors, Dissectors, Specialty Instrumentation (Biopsy Punch, Needle Holders) SHAFTS: –Two standard lengths: 33cm or 45cm –Available Sizes: 3mm, 5mm and 10mm Mono-polar Options
37
Bi-polar Laparoscopic Instrumentation Modular system –4 Components Handle Inner Shaft Outer Shaft Working Insert Sterilization –Autoclave –EtO
38
Advantages of the GENICON Bi-Polar Ergonomic handle Rotates 45 degrees Coated non-stick inserts One-Piece vs. Modular System Two Components Three Components Four Components
39
Multiple Tip Options –Basic Four Hirsch Paddle Forceps Micro Forceps Kleppinger Bi-polar Options Available Lengths - 33cm - 45cm Adaptable to all Generators
40
Disposable Monopolar
42
Features & Benefits Full 360º Rotation Switchable ratchet easily operated with left hand or right hand Full length insulation protects tissue from electrocautery arcs Double action hinge Angled HF connector
43
Advantages Sterile (2 year shelf life) Reliable Quality with every new disposable instrument HF Connection for cauterization and dissection Full length insulation Double Action Jaws increases the range of jaw motion for easier access and precision techniques Comfortable and Easy to Use 360˚ Rotation Single finger operation
44
LAVAGE SYSTEM
45
Features and Benefits of the Suction Irrigation Handpiece High capacity tubing Easy flow Low clogging Ergonomic handpiece Easy to handle Added comfort Precision operation (double seal valves) Prevents leakage
46
Powered Suction Irrigation
47
717-000-000 Irrigation Pump: GENICON Powered Irrigation Pump Tube Set 5mm x 33cm Powered Suction Irrigation Tube Set with Handpiece (710-305-033) – Worldwide Standard
48
Irrigation pump Features and Benefits Easy Setup / Easy to Use Continuous High Flow Rate 1.8 liters per minute Quiet Reusable Compact Can be mounted on an IV pole or placed on a table
49
Lavage System Accessories J Hook Mono- Polar Probe Spatula Mono- Polar Probe L Hook Mono- Polar Probe Reusable Vent Probes Reusable vent probes and a line of mono-polar electrocautery probes
50
Parastolic design Irrigation flow rate: 1.8 L/min Irrigation pressure: 400mm Hg (± 500mm Hg) High pressure safety feature: 500mm Hg (after 5 sec) –shut down Weight: approx. 5.45 kg (12 lbs.) Technical Specifications of the 717-000-000
51
Standard Probe –Rolled Distal Tip –Numerous vents at tip Mono-Polar Cauterization Probes –Used to stop bleeding while irrigating in abdominal cavity –Ceramic tip Helps to eliminate chance of arching inside the abdominal cavity Features: Suction/Irrigation Probes:
52
Uses: Useful as blunt dissectors prior to activation Used to isolate tissue to be divided by the current –During Use: Tissue is hooked and tented up (away from underlying tissue) to limit spread of current and to prevent inadvertent damage –May also be used to mark out a line for division Use heel of hook to create a dotted line using short bursts of soft coagulating current Mono-Polar Cauterization Probes: Mono-Polar Cauterization Probes:
53
Specimen Retrieval Bag
54
Features “UP” Indicator 10mm Diameter Tube with Pre-loaded Bag 235 or 350 cc Capacity Transparent Bag 26cm Introducer
55
Specimen Retrieval Bag Ordering Information Part NumberDescriptionUOM Specimen Retrieval Bag 550-000- 003 10mm Specimen Retrieval Bag, Medium (235 cc capacity) 10 550-000- 001 10mm Specimen Retrieval Bag X-TRA Large (350 cc capacity) 10
56
Specimen Retrieval Bag - Features Facilitates Specimen removal from the abdominal cavity Minimize contamination of the abdominal cavity Large bag - 235+ CC capacity X-Large bag - 350+ CC capacity Automatically opens bag upon deployment 120mm opening For use with10mm or larger cannula Easy to read indicator for bag orientation Latex free Packaged sterile (ETO), 10 per box
57
2009 New Products Titanium Clips Clip Applicator Disposable Articulated Disector
58
6869 Stapoint Court, #114 Winter Park, FL 32792 Primary Phone +1.407.657.4851 USA Toll-Free 800.936.1020
Similar presentations