Inputs: 8 - 4 Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully user programmable display 6 User configurable Buttons. Back-Lit Display Modbus Ascii Communications via programming port Double the memory of Millenium II Standard Version – CD12
4
Inputs: 12 - 6 Digital and 6 configurable for Digital or 10 bit Analog Outputs:8 - 8 amp Relays or 700ma Transistors (4 PWM) 4 Line by 18 Character fully user programmable display 6 User configurable Buttons. Back-Lit Display Modbus Ascii Communications via programming port Double the memory of Millenium II Standard Version – CD20
5
Same features as Standard Controller without Display and Buttons 12 and 20 I/O Models Cost Saving Design 10 bit Analog inputs on DC powered controllers Relay and Transistor models Modbus Ascii Communications via programming port Double the memory of Millenium II Economy Version – CB Series
6
Inputs:6 - 2 Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully user programmable display 6 User configurable Buttons. Back-Lit Display Modbus Ascii Communications via programming port 4 times the memory of Millenium II Wide array of expansion modules Expandable Version – XD10
7
Inputs:16 - 10 Digital and 6 configurable for Digital or 10 bit Analog Outputs:10 – Relays(8x8a / 2x5a) or 700ma Transistors (4 PWM) 4 Line by 18 Character fully user programmable display 6 User configurable Buttons. Back-Lit Display Modbus Ascii Communications via programming port 4 times the memory of Millenium II Wide array of expansion modules Expandable Version – XD26
8
Expand up to 50 I/O RS485 Modbus Communication module Modbus TCP/IP Ethernet Communication module 2 Input 2 Output 10 bit analog expansion module 6, 10, and 14 I/O expansion modules 2 modules can be added to 1 base controller Simplified wiring and installation of modules Expansion Options
10
3 PT100 Inputs 10 bit resolution Heating Control Cooling Control XA03XA04 2 Analog 10 bit Inputs 2 Analog 10 bit Outputs 0-10VDC Input 0-20ma Input Direct Connection of PT100 Expansion Modules XA03 – PT100 Module XA04 – Analog I/O Module
11
Serial RS485 Modbus RTU or Ascii 4 16 bit Input registers 4 16 bit Output registers Perfect for external HMI’s XN03 XN05 Ethernet Modbus TCP/IP Static or Dynamic IP 8 16 bit Input registers 8 16 bit Output registers Easy SCADA Integration
12
Communications
13
Interfaces to wired or GSM cell phone modems Monitor remote applications via PC or cell phone Send text messages to cell phones Control the M3 via cell phone or PC Using M3 Alarm software use your PC to log alarms Modify or download a new program remotely M3MOD – Modem Interface Modem Communications
14
M3 Alarm Software Screen 1: Local/Remote 2:Menu Bar 3:Icon Bar 4:Alarm Display
15
Millenium 3 offers the largest display available on micro-PLC’s. The 4 line by 18 character display provides the ability to add more descriptive text to applications. No More Abbreviations!!!
16
Programming and Communications Interfaces Standard RS232 DB9 Programming Cable New USB cable- No converter required New Bluetooth Interface – Program wirelessly All interfaces can be used to access the Modbus functionality of the programming port.
17
DC to DC Converters Input 9-18 VDC output 12 VDC Input 16-36 VDC output 24 VDC Nominal Power 10W For use in applications with power fluctuations
19
Millenium 3 Software Enhancements
20
Software Enhancements Function Block Programming SFC – Sequential Flow Control Combine Function Block & SFC Ladder Logic Faster Cycle Time Create Macro – Make your own functions! New Simulation features
22
Software Enhancements All timers grouped into a single icon with dynamic operation.
23
Timer LI Function Block Added function for starting with OFF Time First
24
Software Enhancements Timers can now be configured with an external set point. The value can come from another function block or an Analog Input / Potentiometer.
25
Software Enhancements Timers can now be adjusted in units other than.1s All timers can be set for a base unit of.1s or Hours/Minutes/Seconds or based on the cycle time of the controller.
26
Software Enhancements The controller can now be switched into run mode without resetting non-retained values.
27
Software Enhancements “Save values at power break” added on all function with “actual values” “Modification allowed” added on all function with parameters “Edit” menu, added function “re-do” in addition to the “undo” (multi-level) Added new function block which gives information about the state of the controller
28
Software Enhancements Data can now be sent and retrieved through the programming port. The SL In and SL Out function blocks give access to 48 16 bit words. 24 In and 24 Out. A PLC or PC can be used to log data or set values in the controller
29
Software Enhancements Input and Output blocks can now be assigned a custom icon.
30
Software Enhancements New simulation mode features allows easy verification of Time Prog Function block events.
31
Software Enhancements Slider bars have been added to easily modify analog values durring simulation.
32
Millenium 3 Applications
33