Chimney Fires Construction, Challenges Fire Control Best Practices
2
Objectives Review different types of chimney construction Identifying lines vs. unlined flues Understand fire spread characteristics of most common chimney types Effective fire control practices
3
Chimney Construction The chimney method of smoke removal has been around for centuries Early man discovered the benefits of vertical draft methods in removing smoke from caves, huts, etc.
4
Chimney Construction (cont.) Various means to construct vertical drafts (chimneys) used: –Stone –Mud/sticks –Hollow logs –Bricks –Metal (modern)
5
Attachment Methods Interlock wall stones with chimney stone Free-standing Wall logs interlocked in stone or brick Metal ties to wall framing (20 th century) Metal bracing within wood framework (modern zero-clearance chimney piping)
6
Lined Flue Inside of chimney construction contains flue “pipe” or “lining” that minimizes openings, joints, or crevices along vertical path of heat, smoke, embers
7
Metal Chimney Liner
8
Tile Chimney Liner
9
Liner Characteristics… Each type of liner has it’s benefits and drawbacks… –Metal is expensive, but crack resistant and often installed in one piece top-to-bottom. –Most common sizes are 6- and 8- inch –Easy connection to wood/coal stoves –Can be routed through some twists and turns –Can retrofit old, unlined flues
10
Liner Characteristics (cont.) Tile, or terra cotta, offer wider passages than metal and are less expensive than metal Not used in retrofits or relining of existing flues Susceptible to temperature extremes and settling of foundations, causing cracking May consist of several joints
11
Zero-Clearance or Prefabricated Metal Chimney Flues Developed nearly 25 years ago to service the growing alternative heating market Consist of multiple layers of stainless steel separated by fire- retardant insulation
12
Unlined Flues Found in many homes built prior to 1930 May be of stone or brick construction
13
Unlined Flues (cont.)
14
Fire Spread Characteristics
15
Tile/Terra Cotta Liners Cracks appearing over time and temperature extremes provide openings for hot ash/embers to exit the flue and contact adjacent combustible framing members May also provide path into void spaces, carrying sparks into area containing combustibles (attic, behind knee wall)
16
Terra Cotta/Tile Liner (cont.) Subject to degradation from rain, ice, snow Mechanical damage from improper cleaning, previous fires Damage introduced from exterior forces (wind, trees)
17
Metal Chimney Liners May warp from extremes in temperature (burning stove too hot) Improper attachment of flue sections
18
Metal Flues (cont.) Joints may be open, allowing sparks and embers to escape into void and combustible spaces adjacent to chimney, permitting fire spread and slow detection of same. Stainless steel tubular liners are used in older unlined retrofitting, often resulting in turns and twists permitting build up of creosote and animal nests.
19
Creosote Buildup Creosote is a byproduct of INCOMPLETE combustion. Adheres to tile, unlined, flexible metal, and joints in flue liners
20
Creosote (cont.) Relatively cool temperatures in upper portion of flue condense products of combustion into potential “time bombs” on liners. Can be minimized by burning proper fuels (seasoned wood) at proper temperature recommended by stove/fireplace manufacturer
21
Animal Nest in Chimney Flue
22
Retrofitting Unlined Flues It is common to find older, unlined chimneys outfitted with new style flexible, stainless steel tubular liners Often connect to wood stove or insert May be placed in unlined flue surrounded by fire-resistant material such as a vermiculite/gypsum mix
23
Prefabricated Metal Chimneys Have Class “A” fire rating and may be used inside of wooden box framing according to building codes and Underwriter’s Laboratories test results Lock together in a twisting motion Are NOT fire PROOF!!!
24
Identifying Fire Presence and Control Options
25
Caller Complaints Hear persistent “roaring” sound from upper flue area Smoke from chimney when no active fire in fireplace/ stove Haze/smoke odor in upper floors of house and/or attic Walls adjacent to chimney hot to touch
26
Fire Control Tactics Thermal Imager A MUST!!!! Get personnel ABOVE and BELOW fireplace/stove-check walls, floor space adjacent to flue--attic Check flue clean out (if present) Roof crew to check openings at top
27
Tactics (cont.) Remove active fire from firebox Closely monitor flue for active flames Consider use of dry chemical extinguisher or “chimney bombs” (dry chem in plastic baggies dropped from top of chimney) Pressurized water extinguisher and/or preconnect should be LAST RESORT
28
Once fire controlled, occupant must be directed to have licensed chimney sweep clean and inspect chimney PRIOR to ANY additional usage. Officer should document this on NFIRS report.
29
Points to Consider… Successful control of chimney fires requires time and patience Continual monitoring of all adjacent combustible areas required during operations Older, unlined flues often contain structural framing members tying chimney to house
30
Other Important Considerations… EARLY laddering of roof Use of chimney chains to clear flaming creosote (if available on scene) Aggressive investigation of adjacent void spaces Identification of lined vs. unlined flue
31
Summary Firefighters should be familiar with the various chimney types Understand particular hazards of each type of flue Recognize signs of active fire situations in flue and execute proper control methods
32
Summary (cont.) Make every attempt to control fire while minimizing damage to chimney/flue structure Ensure safe operations when working in poor lighting and on wet/icy or steep roof pitches
33
Have a safe, happy, injury- and fire-safe holiday season!!!!!