Download presentation
Presentation is loading. Please wait.
Published byAlanis Speed Modified over 9 years ago
1
1 Mixing Zones, Reasonable Potential Analysis, and Permit Limits A Quick Overview Steve Schnurbusch Oregon Department of Environmental Quality schnurbusch.steve@deq.state.or.us (503) 378-8240 x284 1
2
2 Brief discussion of mixing zones Mixing Zone definitions and terminology Application of mixing zones Types of mixing zone evaluations Performing a reasonable potential analysis Developing water quality-based effluent limits (WQBELs) 2
3
3 3
4
4 Ambient density stratification causes boundary interaction in the form of terminal level formation (Image: Hotler, ETH).density stratification (Photo: I. Wood, Univ. of Canterbury) 4
5
5 5
6
6 Alien Waste Management 6
7
7 A small area around an outfall pipe where water quality criteria are allowed to be violated The Clean Water Act allows the use of mixing zones. EPA does not have any mixing zone rules. Each state must adopt their own rules subject to EPA approval. Mixing zones are allowed for the initial mixing of waste but not for treatment. 7
8
8 Zone of Initial Dilution (ZID) – small area in the immediate vicinity of the outfall where acute toxicity is allowed (also called the “acute” mixing zone) Dilution – the combined flow of the effluent and stream flow divided by the effluent flow Acute Toxicity – The ability of a substance to cause severe biological harm or death soon after a single exposure or dose. Chronic Toxicity – The capacity of a substance to cause long-term or delayed adverse health effects. Mixing Zone – small area in the vicinity of the outfall where chronic toxicity is allowed (also called the “chronic” mixing zone) 8
9
9 Dilution Factor = Dilution Ratio = (Used by Cormix and Visual Plumes) 8a
10
10 Acute Criterion – the highest instream concentration of a toxicant or an effluent to which organisms can be exposed for a brief period of time without causing an acute effect. Chronic Criterion – the highest instream concentration of a toxicant or an effluent to which organisms can be exposed indefinitely without causing unacceptable effect. Human Health Criterion – the highest concentration of a pollutant in water that is not expected to pose a significant risk to human health. 9
11
11 Acute Mixing Zone - must be limited in size to prevent lethality to drifting organisms – acute criteria must be met at the edge of this zone (ZID). Chronic Mixing Zone - sized to protect the integrity of the waterbody as a whole – chronic criteria must be met at the edge of this zone (Mixing Zone). Human Health - allows complete mix with the waterbody 10
12
12 Prevent lethality to drifting organisms Protect overall integrity of the water body Allow for fish passage Avoid shore hugging plumes Avoid bottom attachment Avoid overlap with critical habitat 11
13
13 The allowable mixing zone is that portion of the Sandy River from the point of discharge to 100 feet downstream of the point of discharge. The zone of initial dilution (ZID) shall be defined as that portion of the allowable mixing zone that is within 10 feet of the point of discharge. 12
14
14 The allowable mixing zone is that portion of the Pacific Ocean contained within a radius of two hundred fifty (250) feet from the outfall. The Zone of Immediate Dilution (ZID) shall be defined as that portion of the allowable mixing zone that is within twenty five (25) feet of the point of discharge. 13
15
15 That portion of the Willamette River extending from 10 feet upstream to 500 feet downstream and no more than ¼ the stream width at the point that the City of Eugene Millrace Stormwater System discharges to the Willamette River. The Zone of Immediate Dilution (ZID) shall be defined as that portion of the allowable mixing zone that is within fifty (50) feet from the point of discharge. 14
16
16 Dye Studies MZ Modeling 15
17
17 CORMIX Applicable for riverine, estuary, and ocean outfalls Simulates boundary interactions, bottom attachments, and unstable discharges Visual Plumes Applicable for “unbounded” water bodies only Simulates stable discharges with no boundary interactions CORMIX Simulation 16
18
18 2. Dilution at Edge of Mixing Zone 1. Dilution at Edge of ZID 17
19
19 18
20
20 Statistical method used to determine if a discharge causes, has the reasonable potential to cause, or contribute to an in-stream excursion above a water quality standard The EPA methodology takes into account: TThe variability of the pollutant parameter TThe available dilution BBackground concentration of pollutant upstream 19
21
21 Lead:n = 20Max = 25 ug/L Mean = 15 ug/LStddev = 6 Available dilution at MZ = 50 RPA Steps: 1.CV = stddev/mean = 6/15 = 0.4 2.Multiplying factor based on 20 samples and CV of 0.4 = 1.4 3.Maximum probable value = 25 x 1.4 = 32.5 ug/L 4.Instream concentration at MZ = 32.5/50 = 0.65 ug/L 5.Chronic lead criterion = 0.60 mg/L 6.0.65 > 0.60 mg/L so there is a reasonable potential to violate lead 20
22
22 CFR 122.44(d)(1)(ii) states that if the permitting authority determines a pollutant has the reasonable potential to cause or contribute to an excursion above a water quality criteria, the permit must contain effluent limits for that pollutant. EPA has developed a permit limit derivation methodology that takes into account: Background concentration of pollutant Available dilution Variability of the effluent data Water quality criteria 21
23
23 22
24
24 Brief overview of mixing zones Applied results of a mixing zone analysis to a Reasonable Potential Analysis Developed WQBELs that will be used in the Local Limits Evaluation 23
Similar presentations
© 2024 SlidePlayer.com. Inc.