Download presentation
1
Multi Functional Digital Fault Recorder
2
INTRODUCING THE BLACKBOXDFR
Fully Featured Digital Fault Recorder For Transmission & Distribution Substations PMU Class A Power Quality Monitoring Single or Double Ended Impedance-Based Fault Location Energy Metering Multi-Functional 0.1% Accuracy on Analog Channels Class A Power Quality 0.1% Power & Energy Accuracy … Surpassing: IEC Class 0.2S ANSI C Class for Energy 24 Bit Continuous 1024 Samples Per Cycle Highly Accurate PMU Measurements 1 μsecond Time Synchronization
3
BUILT-IN WEB SERVER GENERAL OVERVIEW INVESTIGATION EVENTS
Full Measurement & System Status RMS THD Trends System Information System Status Events INVESTIGATION 10,000 Parameters over 16 Analog & 96 Digital Channels: 1 μsecond Zoom Monitor Network System Condition Detect Instabilities Predict Future Failures Scopes, Trends, Statistics, Summaries, Spectrums … EVENTS Digital Input OR PQ Events: Dips, Swells, Interruptions, Transients, DI …. Custom Events Exceed Limitations Parameters DX/DT Event Aggregation Logic Operator AND, OR, XOR
4
WEB-ENABLED DEVICE FULLY FEATURED WEB SERVER - HTML5 WEB TECHNOLOGY
Utilizing …. Widely Used Web Browsers: Firefox Internet Explorer Safari & more … Common Smart Devices: Android iOS Windows 8
5
REAL-TIME MONITORING 5” COLOR TOUCH LCD 1 Point Access in Real-Time:
All System Functions Configurations Measured Values Interactive: Easy to Operate Full Color User-Friendly Interface
6
IR Port (Metering/Maintenance)
SYSTEM ARCHITECTURE LAN (PQZ, IEC 61850, DNP3, MODBUS) GPS/IRIG B Serial Port 2 x Synch Ports 2 x USB Ports IR Port (Metering/Maintenance) Power Quality PMU Metering Event Detection Fault Locator 16 AC/DC Analog Inputs Digital I/O Sensor Inputs 5” Color Touch LCD 1 Year Waveform Recording 10,000 PQ Parameters 20µs – 2 Hrs Resolution Metering
7
ARCHITECTURE – SINGLE OR DOUBLE SYSTEM ADAPTIBILITY
FRONT VIEW LCD Touch Screen 1 Handles 2 IR Data Port 3
8
ARCHITECTURE – SINGLE OR DOUBLE SYSTEM ADAPTIBILITY
REAR VIEW Communication Ports Custom Modular Design PPS / IRIG B Port Spare Slot 1 6 RS485/422 Serial Port Up to 16 Analog Channels 2 7 2 x DSP Sync In & Out Ports Up to 96 Digital Channels 3 8 LAN Port 4 Main Power ON/OFF Switch 9 2 x USB Ports 5 Main Power Inlet Socket 10
9
PORT CONFIGURATIONS Voltage Analog Inputs: 0, 4, 8, 12, 16
Current Analog Inputs: Digital Status [In] 0 to 96: Increments of 32 Control Output 0 to 48: Increments of 16 LAN Port: 1 Serial Port: IR Port: PPS Time Sync: USB Ports: 2 DSP Sync: 2 [In & Out]
10
PHYSICAL DIMENSIONS FRONT VIEW REAR VIEW FRONT VIEW SIDE VIEW
DIMENSIONS (W x H x D) EXCLUDING ENCLOSURE Single 21.5 x 22.1 x 29.1cm (8.48 x 8.7 x 11.45”) Double 43.1 x 22.1 x 29.1cm (16.96 x 8.7 x 11.45”) DIMENSIONS (W x H x D) INCLUDING ENCLOSURE Single (Side Empty) & Double 48.3 x 22.1 x 29.1 cm (19 x 8.7 x 11.45”)
11
TIME SYNCHRONIZATION GPS/IRIG B 1 µsec Accuracy to the Master Clock
SNTP 100 nsec Between Modules DSP SYNCHRONIZATION
12
DIGITAL FAULT RECORDING
1 Year Continuous Waveform Recordings 1,024 Sample/Cycle per Analog Channel (50/60Hz) 128 Sample/Cycle per Digital Channel (50/60Hz) Unlimited Triggers Digital Input Change Analog Exceed Limitations Parameters DX/DT Fault Locator One Ended Impedance-Based: Designed for Locating Faults on Single-Circuit Lines Two Ended Impedance-Based: Designed to Measure Two-Ended Synchronized Recordings of Voltage & Currents, Formulating Frequency Phasors of Symmetrical Components
13
CLASS A POWER QUALITY Measure & Record More Than 10,000 Parameters
Unbalance 511 Harmonics Inter-Harmonics THD RMS & More … Power Quality Events Voltage Dips Voltage Swells Voltage Interruptions
14
CLASS A POWER QUALITY Custom Events Transient Events Compliance Engine
Per any Measured Parameter DX/DT for any Measured Parameter Transient Events Event Capture per Waveform Signal Compliance Engine EN50160 Custom Compliance – Geared to Meet any Grid Code
15
PHASOR MEASUREMENT UNIT (PMU)
Measurement of Vector Quantities: Highly Accurate According to IEEE C – 2005 1µsec Time Synchronization On-Board Solution: Continuous Phasor Recording and Transmitting ½ Cycle Transmission Rate
16
Integrated High Precision Energy Meter – Measure & Record:
0.1% Power & Energy Accuracy … Surpassing: IEC Class 0.2S ANSI C Class for Energy Flow of Energy within a System: Reactive Power Active Power Apparent Power Power Factor Flow of Power To & From the System to the Grid: Delivered Received
17
BLACKBOX ARCHITECTURE
18
PQSCADA 5 – OVERVIEW [SINGLE MAP]
19
PQSCADA 5 – OVERVIEW [MULTIPLE MAPS]
20
PQSCADA 5 – OVERVIEW [ELECTRICAL MAP]
21
PQSCADA 5 – OVERVIEW [TOPOLOGY]
22
PQSCADA 5 – POWER QUALITY
23
PQSCADA 5 – POWER QUALITY
24
PQSCADA 5 – POWER QUALITY
25
PQSCADA 5 – POWER QUALITY
26
PQSCADA 5 - INVESTIGATOR
27
BLACKBOXDFR - THE PERFECT DFR SOLUTION
MULTI CHANNEL – UP TO 16 ANALOG & 96 DIGITAL CHANNELS PER MODULE HIGHLY ACCURATE MEASUREMENTS ULTRA FAST SAMPLING RATE INTEGRATED DB FOR SW FREE INVESTIGATION PQZIP II – FOR REAL TIME COMMUNICATION
28
THANK YOU
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.