Presentation is loading. Please wait.

Presentation is loading. Please wait.

To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼

Similar presentations


Presentation on theme: "To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼"— Presentation transcript:

1 To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼ 3-Point (a-b) ▼ 3-Point ▼ Repeated Küpfmüller ▼ Capacitive unbalance ▼ Resistance difference Low level Constant level Intermittent low level Intermittent Strongly changing fault resistance Flooded cable Insulation faults Sensitive Protected Sensitive Protected Which one is the Proper Fault Location Method ? ELEKTR NIKA

2 Disturbers The expected disturbing voltage depends on: A.) The function of neighboring pairs in the cable Intermittent disturbing voltages are expected if the neighboring pairs are used for POTS DC disturbing voltage is expected if the neighboring pairs are used only for ISDN No disturbing voltage is expected if the neighboring pairs are used only for data transfer B.) The distance to electrical railway High disturbing AC voltage is expected if the cable is very close to the track Low disturbing AC voltage is expected if the cable is fare enough from the track ELEKTR NIKA

3 Murray Method in Sensitive mode The result of Murray measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 450 uA ■ Ф wire a=Ф wire b ■ FbE>1000 x FaE ■ FbE>10 MOhm If the disturbing voltages overload the input repeat the measurement in Protected mode Recommended when: ■ only one wire of a pair is faulty ■ the level of disturbing voltages are low The Murray method consists of 2 measurements: ■ Measurement of disturbing voltages ■ Bridge measurement with strap on the far end ELQ 30A automatically performs the 2 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA

4 Murray Method in Protected mode The result of Murray measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 7 mA ■ Ф wire a=Ф wire b ■ FbE>1000 x FaE ■ FbE>10 MOhm Recommended when: ■ only one wire of a pair is faulty ■ the disturbing voltages are not intermittent The Murray method consists of 2 measurements: ■ Measurement of disturbing voltages ■ Bridge measurement with strap on the far end ELQ 30A automatically performs the 2 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA

5 Küpfmüller Method in Sensitive mode The result of Küpfmüller measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE and FbE insulation resistances ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 450 uA ■ Ф wire a=Ф wire b ■ 0,5>FaE / FbE>2 ■ FaE + FbE>100 x R loop If the disturbing voltages overload the input repeat the measurement in Protected mode Recommended when: ■ booth wires of a pair are faulty ■ the level of disturbing voltages are low The Küpfmüller method consists of 2 measurements: ■ First measurement with open far end ■ Second measurement with strap on the far end ELQ 30A calculates the Lx/L value from the results of the two measurements The far end can be automatically closed and open with the help of the remote controlled switch ELC 30 ELEKTR NIKA

6 Küpfmüller Method in Protected mode The result of Küpfmüller measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE and FbE insulation resistances ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 7 mA ■ Ф wire a=Ф wire b ■ 0,5>FaE / FbE>2 ■ FaE + FbE>100 x R loop Recommended when: ■ booth wires of a pair are faulty ■ the disturbing voltages are not intermittent The Küpfmüller method consists of 2 measurements: ■ First measurement with open far end ■ Second measurement with closed loop ELQ 30A calculates the Lx/L value from the results of the two measurements The far end can be automatically closed and open with the help of the remote controlled switch ELC 30 ELEKTR NIKA

7 Repeated Küpfmüller Method in Sensitive mode Recommended when: ■ The level disturbing voltages are low ■ The fault resistances are strongly changing That method is a sequence of repeated Küpfmüller measurements consisting of 15 part measurements alternating : ■ 8 measurements with open loop (L) ■ 7 measurements with closed loop (K) The far end is automatically closed/open with the help of the remote controlled switch ELC 30 When the sequence is completed ELQ 30A selects the acceptable Lx/L results and calculates the average of the accepted results. The unacceptable results are omitted and marked with asterisks. The Lx/L results are displayed in two columns and a histogram ELEKTR NIKA

8 Repeated Küpfmüller Method in Protected mode Recommended when: ■ The disturbing voltages are intermittent ■ The fault resistances are strongly changing That method is a sequence of repeated Küpfmüller measurements consisting of 15 part measurements alternating : ■ 8 measurements with open loop (L) ■ 7 measurements with closed loop (K) The far end is automatically closed/open with the help of the remote controlled switch ELC 30 When the sequence is completed ELQ 30A selects the acceptable Lx/L results and calculates the average of the accepted results. The unacceptable results are omitted and marked with asterisks. The Lx/L results are displayed in two columns and a histogram ELEKTR NIKA

9 3-Point (a-b) Method in Sensitive mode Recommended when: ■ the insulation between wires and ground is good ■ the insulation resistance between wires a and b is low ■ some healthy pairs are available ■ the level of disturbing voltages are low The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 450 uA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. If the disturbing voltages overload the input repeat the measurement in Protected mode The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty pairFaE

10 3-Point (a-b) Method in Protected mode Recommended when: ■ the insulation between wires and ground is good ■ the insulation resistance between wires a and b is low ■ some healthy pairs are available ■ the disturbing voltages are not intermittent The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 7 mA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty pairFaE

11 The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 450 uA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. If the disturbing voltages overload the input repeat the measurement in Protected mode Recommended when: ■ the gauge of wires in a pair are different ■ some healthy pairs are available ■ the level of disturbing voltages are low The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty wire FaE 3-Point Method in Sensitive mode

12 The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 7 mA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. Recommended when: ■ the gauge of wires in a pair are different ■ some healthy pairs are available ■ the disturbing voltages are not intermittent The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty wire FaE 3-Point Method in Protected mode

13 ELQ 30A provides the following results: ■ Ra and Rb wire resistances ■ RL loop resistance ■ Δ R resistance difference ■ % The condition of accurate results is: Ia and Ib < 450 uA If the disturbing voltages overload the input repeat the measurement in Protected mode ELQ 30A automatically performs the measurements with the help of the remote controlled switch ELC 30 The resistance difference measurement is recommended if the balance of the tested pair is poor Resistance Difference Measurement in Sensitive mode ELEKTR NIKA

14 Resistance Difference Measurement in Protected mode ELQ 30A provides the following results: ■ Ra and Rb wire resistances ■ RL loop resistance ■ Δ R resistance difference ■ % The condition of accurate results is: Ia and Ib < 7 mA That condition is practically always fulfilled. ELQ 30A automatically performs the measurements with the help of the remote controlled switch ELC 30 The resistance difference measurement is recommended if the balance of the tested pair is poor ELEKTR NIKA

15 ELQ 30A provides the following results: ■ Lx/L ■ CaE and CbE wire capacitances ■ Δ C capacitance difference in nF ■ Δ % capacitance difference in % The condition of accurate results is: Ia and Ib < 450 uA If the disturbing voltages overload the input repeat the measurement in Protected mode The resistance difference measurement is recommended if the balance of the tested pair is poor Capacitance Unbalance Measurement in Sensitive mode ELEKTR NIKA

16 Capacitance Unbalance Measurement in Protected mode ELQ 30A provides the following results: ■ Lx/L ■ CaE and CbE wire capacitances ■ Δ C capacitance difference in nF ■ Δ % capacitance difference in % The condition of accurate results is: Ia and Ib < 7 mA That condition is practically always fulfilled. The resistance difference measurement is recommended if the balance of the tested pair is poor ELEKTR NIKA

17 THANK YOU FOR YOUR ATTENTION!


Download ppt "To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼"

Similar presentations


Ads by Google