Download presentation
Presentation is loading. Please wait.
Published byIsabella Ramshaw Modified over 9 years ago
1
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Effektivare kylsystem för kyl & och frysskåp Erik Björk, PhD student, KTH Björn Palm, Supervisor, KTH Per Wennerström, controller, Electrolux/RDE
2
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Background Black box Rule of thumb design Copy old designs Open box Design based on science (heat transfer, pressure drop and charge) Energy consumption Legislations Customers demand Reduced Energy consumption compressor evaporator cap. tube condenser
3
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden The plate evaporator (ER8893C) Aluminium, 660 x 490 mm Thickness 1.4 mm 1.35 kg White coated Tube length 6.22 m Hydraulic diameter 3.2 mm Total internal volume 115.7 ml Accumulator volume 45.6 ml
4
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden The plate evaporator (ER8893C)
5
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden On-off cycling characteristics
6
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Charge distribution – experimental results
7
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Comparison theory - experimental results Evaporator Condenser
8
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Activation delayed by redistribution process
9
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Downward slope reduces activation time
10
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Accumulator delays activation
11
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Air side heat transfer – experimental results
12
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Refrigerant side heat transfer – experimental results Mass flow
13
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Refrigerant side pressure drop – experimental results
14
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Optimum pitch
15
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Fin efficiency for the whole evaporator ≈ 97,2%
16
Erik Björk, M.Sc. Dept. of Energy Technology Div. of Applied Thermodynamics and Refrigeration Royal Institute of Technology Sweden Increased pitch Distributed accumulator Downward sloping channels Small diameter at inlet – large at outlet Channels close to plate edges Conclusions improved evaporator design
Similar presentations