Download presentation
Presentation is loading. Please wait.
Published byEsperanza Waight Modified over 9 years ago
1
Topsfield Engineering Service, Inc. Figure 1 Thermoelastic Analysis in Design William Bell & Paul-W. Young Topsfield Engineering Service, Inc. John Stewart, Saber Design and Analysis Services, LLC.
2
Topsfield Engineering Service, Inc. Slide 2 Purpose This study explores the capability of Thermal Desktop to map temperatures from a thermal model to a Nastran model to evaluate thermal stress and distortion
3
Topsfield Engineering Service, Inc. Slide 3 Applications n Rapid cool-down to cryogenic temperatures n Differential thermal expansion causing leakage, failure, galling, or seizing n Electronics components n Misalignment due to thermal distortion n Time dependent and steady state conditions n Space optics - optical alignment n Gasket/seal seating - pressure containing n Thermal contact joint design
4
Topsfield Engineering Service, Inc. Slide 4 Tools Used n Thermal Desktop from C & R Technologies – Version 4.7 patch 16 n FEMAP V8.3 and NX NASTRAN V2.0
5
Topsfield Engineering Service, Inc. Slide 5 Study Assembly ½” thick heated plate with a serpentine pipe 1/8” sch 40 pipe attached to the plate for temperature control Heat Loads 20 watts/in 2 15 watts/in 2
6
Topsfield Engineering Service, Inc. Slide 6 Thermal Model Development n Evolved from a early version of a Thermal Desktop model n Rebuilt using latest modeling objects without simplifying dimensions n Picked off dimensions from the Autocad drawing for creation of the Nastran model n Result - there were some discrepancies
7
Topsfield Engineering Service, Inc. Slide 7 Thermal Study Conditions n Mass Flow cooling - Coolant – 100 lb/hr of Nitrogen gas at - 200 F and 40 psig – built-in properties for Nitrogen n No Radiation Heat Transfer n Plate is heated with 1150 watts n Conduction within plate and pipe walls n Built in convection equations for heat transfer from pipe to Nitrogen n Steady State Conditions (although Thermal Desktop can solve time dependent cases and search for worst case conditions)
8
Topsfield Engineering Service, Inc. Slide 8 Material Properties n The structural and thermal properties used in the analysis models are values commonly used for Stainless Steel, Aluminum, and the attachment techniques employed n The property data used can be found in the Nastran and Thermal Desktop model files n In a “real world” problem, the material data would be detailed out and agreed to prior to beginning any analysis. Due to the large temperature differences, temperature dependent properties would also be used
9
Topsfield Engineering Service, Inc. Slide 9 Thermal Desktop Model Construction n Pipe with wall (1/8” nps - sch 40) built on a polyline n Lumps and paths within pipe n Ties representing the convective heat transfer from the pipe wall to the fluid lumps n Three brick objects with edge nodes merged for the plate except for Case D where the plate was created from the Nastran grooved plate. Plate is ½” thick n Heat flux applied to the bottom surface of two of the bricks n Contactor object to represent the pipe to plate bond. In the groove the bond thickness is 0.003”. The weld to the flat plate is an 1/8” fillet
10
Topsfield Engineering Service, Inc. Slide 10 Cases evaluated in Nastran A - Pipe bonded to grooved plate – Nastran pipe and plate from chexa elements B - Pipe bonded to grooved plate – Nastran pipe from cquad4 elements and plate from chexa elements C - Pipe welded to flat plate – Nastran pipe from cquad4 elements and plate from chexa elements D - Pipe bonded to grooved plate – Nastran pipe and plate from chexa elements – TD plate from the Nastran plate
11
Topsfield Engineering Service, Inc. Slide 11 Case Material Combinations Case At1, Bt1, Dt1 - SS plate; SS pipe; easyflo braze Case At2, Bt2 - Al plate; Al pipe; Al braze Case At3, Bt3 - Al plate; SS pipe; epoxy bond Case Ct1 - SS plate; SS pipe; SS weld Case Ct2 - Al plate; Al pipe; Al weld
12
Topsfield Engineering Service, Inc. Slide 12 Cases A and B Pipe bonded to a groove in the plate. Case B – pipe from cquad4 elements and plate from chexa elements Case A – pipe and plate from chexa elements
13
Topsfield Engineering Service, Inc. Slide 13 Case C Pipe with cquad4 elements attached with chexa solid elements to the top surface of the solid plate of chexa solid elements.
14
Topsfield Engineering Service, Inc. Slide 14 Case D Pipe and Plate from chexa elements Pipe bonded to a groove in the plate. TD plate from Nastran plate above, with groove.
15
Topsfield Engineering Service, Inc. Slide 15 Thermal Desktop Geometry Cases A and B Thermal Model Geometry Case C Thermal Model Geometry Case D Thermal Model Geometry
16
Topsfield Engineering Service, Inc. Slide 16 Thermal Desktop ties Ties from the fluid lumps to the pipe wall
17
Topsfield Engineering Service, Inc. Slide 17 Thermal Desktop contactors Contactor connections – shown in yellow
18
Topsfield Engineering Service, Inc. Slide 18 Case A & D Nastran Model Geometry chexa elements thru pipe Bond shown in yellow
19
Topsfield Engineering Service, Inc. Slide 19 Case B Nastran Model Geometry Pipe with cquad4 elements
20
Topsfield Engineering Service, Inc. Slide 20 Case C Nastran Model Geometry Weld bead shown in yellow
21
Topsfield Engineering Service, Inc. Slide 21 Thermal model elements – Cases A & B n Pipe 2448 TD/RC Nodes 1 pipe 1 contactor n Plate 1880 TD/RC Nodes 3 fdsolids 2 heat loads 1 contactor n 12,038 conductors connecting plate and pipe n Fluid 103 lumps 2 plenums 101 junctions 102 paths 1 tie
22
Topsfield Engineering Service, Inc. Slide 22 Thermal model elements – Case D n Pipe 2448 TD/RC Nodes 1 pipe 1 contactor n Plate 78,213 TD/RC Nodes 25,482 plates 65,240 solids 2 heat loads 1 contactor n 909,152 conductors connecting plate and pipe n Fluid 103 lumps 2 plenums 101 junctions 102 paths 1 tie
23
Topsfield Engineering Service, Inc. Slide 23 Nastran Model Construction n Plate and bond built with 95,480 chexa elements for Cases A, B, and D n Plate and weld built with 112,216 cquad4 elements for Case C n Pipe built with 70,908 chexa elements for Case A & D n Pipe built with 23,636 cquad4 elements for Case B & C
24
Topsfield Engineering Service, Inc. Slide 24 Temperature Mapping Procedure n Step 1 – Temperatures from TD plate to Nastran plate n Step 2 - Temperatures from TD plate to Nastran bond, if required n Step 3 - Temperatures from TD pipe to Nastran pipe This avoids mixing pipe and plate temperatures when mapping
25
Topsfield Engineering Service, Inc. Slide 25 Mapping tolerances n Thermal Desktop plate to the Nastran plate and bond, if required – 1e-5” n Thermal Desktop pipe to Nastran pipe – 0.00025”
26
Topsfield Engineering Service, Inc. Slide 26 Results – Case At1 TD Temperature Nastran Temperature Deflection Stress
27
Topsfield Engineering Service, Inc. Slide 27 Results – Case Bt1 TD Temperature Nastran Temperature Deflection Stress
28
Topsfield Engineering Service, Inc. Slide 28 Results – Case Ct1 TD Temperature Nastran Temperature DeflectionStress
29
Topsfield Engineering Service, Inc. Slide 29 Results – Case Dt1 TD Temperature Nastran Temperature Deflection Stress
30
Topsfield Engineering Service, Inc. Slide 30 Results – Case At1 versus Dt1 Dt1 Stress At1 Stress
31
Topsfield Engineering Service, Inc. Slide 31 Results – Case At2 TD Temperature Nastran Temperature Deflection Stress
32
Topsfield Engineering Service, Inc. Slide 32 Results – Case Bt2 Nastran Temperature Deflection Stress TD Temperature
33
Topsfield Engineering Service, Inc. Slide 33 Results – Case Ct2 TD Temperature Nastran Temperature Deflection Stress
34
Topsfield Engineering Service, Inc. Slide 34 Results – Case At3 TD Temperature Nastran Temperature DeflectionStress
35
Topsfield Engineering Service, Inc. Slide 35 Results – Case Bt3 TD Temperature Nastran Temperature Deflection Stress
36
Topsfield Engineering Service, Inc. Slide 36 Case At1 Thermal Results Cross section for temperature and Nastran Results Thermal model node numbers
37
Topsfield Engineering Service, Inc. Slide 37 Case At1 Thermal Results Temperatures in TD plate Temperatures in TD pipe
38
Topsfield Engineering Service, Inc. Slide 38 Case Dt1 Thermal Results Temperatures in TD plate from Nastran model Temperatures in TD pipe
39
Topsfield Engineering Service, Inc. Slide 39 Case At1 Thermal Results Temperatures in Nastran plate from TD model
40
Topsfield Engineering Service, Inc. Slide 40 Nastran Results Summary Cases Maximum Von Mises Stress at Cross Section psi Maximum Deflection - inches Maximum Temperature - F Case At147,1490.02200314 Case At25,5320.0081130 Case At330,5740.0390067 Case Bt139,9680.02300314 Case Bt211,8790.0113030 Case Bt324,1100.0129067 Case Ct136,7620.04200451 Case Ct217,6480.0123055 Case Dt188,3100.02660418
41
Topsfield Engineering Service, Inc. Slide 41 Lessons Learned - thermal n Spend some time reviewing thermal results: Determining if nodalization is sufficient – distortion or stress Choosing materials and material thermal properties Assuring convergence Getting separate files for each component of the model and putting each component on a separate layer n Plan out the combinations with the design team n Carefully check to see if the temperature mapping is accurate n Let go of the fear of finite elements
42
Topsfield Engineering Service, Inc. Slide 42 Lessons learned - structural n Spend some time working with the thermal analyst: Getting dimensions consistent Sorting out materials and structural properties up front Determining the mounting constraint Getting separate files for each component of the model n Plan out the combinations with the design team n Carefully check to see if the temperature mapping is accurate n Do hand calculations as a check on stresses and deflections
43
Topsfield Engineering Service, Inc. Slide 43 Models The Nastran and Thermal Desktop models are available as a down load by going to the following URL: http://www.topeng.com/downloads