Edge Sensors for the Schwarzschild-Couder Telescopes David Hanna McGill University UCLA AGIS Meeting June 26-27, 2008
2
The Requirement: facets on the S-C telescopes need to be positioned to a tolerance of the order of 10 microns light-weight optical support structure will undergo deformations of at least this scale while tracking sources a system of actuators to dynamically correct the facets’ positions and orientations is planned a related system to measure the facets’ positions and orientations must be developed
3
Edge Sensors to measure the displacement of one mirror facet with respect to its neighbour we plan to use a system of position-sensitive detectors (PSDs) illuminated by diode lasers or collimated LEDs. relative motion of the two facets causes the position of the beam spot on the PSD to be displaced; the job of the actuators is to move the facets in order to put the spot back to its nominal position light source PSD beam Mirror 1 Mirror 2
4
for the PSD, we are evaluating a lateral-effect photodiode of the pin-cushion type ( Hamamatsu S5991). - electrodes on the edges of the silicon photodiode collect charges produced by the illumination of the PSD. - ratios of currents from electrodes on opposite sides are used to calculate the centroid of the light pool. - thus the device is non-imaging. - shaped electrodes increase linearity near the edges and produce the pin-cushion-shaped sensitive area. figure from Circuit Cellar (www.circuitcellar.com) Position Sensitive Detectors (PSDs)
5
15 mm - this PSD model is available for $30 each in large quantities. - resolution is 1.5 m Hamamatsu S5991
6
Light Sources: we have two options: laser diode and light-emitting diode (LED) LED – blue(465 nm) Optek Technology ~ $0.70 (shown here with collimator, 1 mm diameter 10 mm long) LASER diode- red (650 nm) BEA lasers ~ $60 The LED can be made bright enough for our purposes but the forward current (80 mA) is larger than the suggested maximum (20 mA) Probably OK since - collimator acts as a very effective heat sink - we can use the LED in a low-duty-cycle mode (needs study)
7
Hamamatsu provides a circuit for reading out the PSD. We have carried out tests on accuracy and stability using the setup shown at the right; the collimated LED is attached to an X-Y-Z translation device which is used to make controlled scans across the PSD - the blue spot below the PSD shows the size of the beam spot obtained using the simple collimator System Evaluation
8
Scan in x and y use micrometer translator to change laser spot position on PSD compare PSD reading with translator position repeat to test for reproducibility
9
Overnight Stability Test leave LED on for 16 hours record x, y and current sunrise +/- 10 um
10
Electronics Developments single PSD circuit op-amps turn currents into voltages for ADCs to digitize
11
4-PSD op-amp board
12
Present status and future plans PSDs and op-amp circuits now at UCLA awaiting tests on mechanical setup new circuit which puts ADC near the op-amp (ie send digital information over cables to improve noise rejection) to be developed this summer at McGill