Download presentation
Presentation is loading. Please wait.
Published byAyana Wintle Modified over 9 years ago
1
AC Inverter Drives 500 Series Product Range Overview 2000 AC Inverter Drives
2
2000 Products Line-Up Small drives 0.20.40.75 FR-S520S - single phase - “Micro Drive” 0.40.751.52.2 FR-E520S - single phase “Compact” 0.40.751.52.23.75.57.5 FR-E540 - three phase “Compact”
3
AC Inverter Drives 1999 Products Line Up 1.555 kW FR-A540 ------- 65535 kW FR-A540L 1.545 kW FR-V240E ( Medium Voltage solutions up to 4.9 MV,6.6 kV to special order ) Large Drives
4
AC Inverter Drives FR-S520S (“S500”) Single Phase 0.2 - 0.75 kW “Jog Dial” setting Inrush control Common Footprint all ratings Digital pot. Feature Full short circuit protection In built Thermal Overload Capability Auto- restart capability RFI filter option - residential levels 3 rd Generation IPM devices RS 485 as an option (ECR version)
5
AC Inverter Drives FR-E520S / E540 (“E500”) Outstanding Dynamic Performance Integral Serial Communications Capability Fieldbus options Cassette filter design (200V) Source / Sink Logic PID Control High Response Current limit control 0 - 10 V analogue output Coasting Motor Restart Phase Loss protection Multiple User Group Pr. settings
6
AC Inverter Drives FR-A540 ‘Flagship’ drive 250 % driving torque at 0.5 Hz On -line auto tune for accurate speed holding - even overhauling ‘Smart Driver’ ASIC = excellent low speed performance Removable terminal block - easy maintenance Open or Closed loop operation Fieldbus Compatible DeviceNet Profibus DP Modbus+ CC-Link PID Control as standard HC Zero Harmonic Module available
7
AC Inverter Drives FR-V240E True Flux Vector Performance Torque Control Positioning Control Zero speed torque Uses any std motor (closed loop) Perfect for hoisting / lifting wire - drawing paper process lines
8
AC Inverter Drives FR-A540L ( Medium Voltage solutions up to 4.9 M VA,6.6 kV to special order ) Extends A500 range up to 535 kW Full A500 capability 6 and 12 pulse versions available series or parallel DC Link choke is standard Frame size is 2- 3 times smaller than competition Totally dependable - often used in site - critical areas without back-ups !
9
AC Inverter Drives MX 500 Programming Capability Greatly Speeds Up... Commissioning Monitoring Diagnostics Works for all ‘500 series’
10
AC Inverter Drives Hardware Tripless Function 100 % Slam Load (slide: Mx500) BENEFIT - enables DOL and Cascade starts
11
AC Inverter Drives Hardware Tripless In Action... Normal 500 Series Drive Trips on shock load
12
AC Inverter Drives Direct HMI Connectivity without PLC CAB9-3M Special driver software allows direct RS 485 communications between any E type HMI and any 500 type inverter. Simpler and quicker interfacing Can be used for multi - drops up to 32 units
13
AC Inverter Drives Support All drives < = 220 kW and accessories held in stock in UK Factory Trained engineers in UK UK engineer based permanently in Japan On site service / tech support 24 Hour hot-line support available Full range of accessories Project and System engineering support Key Partner Mitsubishi Full technical data including technical manuals on CD-ROM Training Courses, general and custom
14
AC Inverter Drives Questions? AC Inverter Drives
15
500 Series Product Range Overview 2000 AC Inverter Drives