Download presentation
Presentation is loading. Please wait.
Published byJayce Cooper Modified over 9 years ago
1
Design of Columns and Beam-Columns in Timber
2
Column failures Material failure (crushing) Elastic buckling (Euler) Inelastic buckling (combination of buckling and material failure) P P Δ L eff
3
Truss compression members Fraser Bridge, Quesnel
4
Column behaviour Displacement Δ (mm) Axial load P (kN) P cr P P Δ Perfectly straight and elastic column Crooked elastic column Crooked column with material failure L eff
5
Pin-ended struts Shadbolt Centre, Burnaby
6
Column design equation P r = F c A K Zc K C where = 0.8 and F c = f c (K D K H K Sc K T ) size factor K Zc = 6.3 (dL) -0.13 ≤ 1.3 d L axis of buckling P
7
Glulam arches and cross-bracing UNBC, Prince George, BC
8
Capacity of a column LeLe PrPr combination of material failure and buckling elastic buckling material failure FcA FcA π 2 EI/L 2 (Euler equation)
9
Pin-ended columns in restroom building North Cascades Highway, WA Actual pin connections Non-prismatic round columns
10
Column buckling factor K C C C = L e /d KCKC 1.0 50 limit 0.15
11
What is an acceptable l/d ratio ?? Clustered columns Forest Sciences Centre, UBC L/d ration of individual columns ~ 30
12
Effective length L eff = length of half sine-wave = k L k (theory)1.00.50.7> 1 k (design)1.00.650.8> 1 non-sway sway* P PP PP P PPPP LeLe LeLe LeLe LeLe * Sway cases should be treated with frame stability approach
13
Glulam and steel trusses Velodrome, Bordeaux, France All end connections are assumed to be pin-ended
14
Pin connected column base Note: water damage
15
Column base: fixed or pin connected ??
16
Effective length L ex L ey
17
Round poles in a marine structure
18
Partially braced columns in a post- and-beam structure FERIC Building, Vancouver, BC
19
L/d ratios LeLe L ey L ex d dydy dxdx x x y y y y
20
Stud wall axis of buckling d L ignore sheathing contribution when calculating stud wall resistance
21
Stud wall construction
22
Fixed or pinned connection ? Note: bearing block from hard wood
23
An interesting connection between column and truss (combined steel and glulam truss)
24
Slightly over-designed truss member (Architectural features)
25
Effective length (sway cases) L eff = length of half sine-wave = k L k (theory)1.02.0 1.0<k<2.0 k (design)1.22.0 1.5 P PP PP P PPPP Note: Sway cases should only be designed this way when all the columns are equally loaded and all columns contribute equally to the lateral sway resistance of a building LeLe LeLe LeLe LeLe
26
Sway frame for a small covered road bridge
27
Sway permitted columns ….or aren’t they ??
28
Haunched columns UNBC, Prince George, BC
29
Frame stability Columns carry axial forces from gravity loads Effective length based on sway-prevented case Sway effects included in applied moments –When no applied moments, assume frame to be out- of-plumb by 0.5% drift –Applied horizontal forces (wind, earthquake) get amplified Design as beam-column
30
Frame stability (P- Δ effects) Δ H W Δ = 1 st order displacement H total = H = amplification factor H = applied hor. load h Note: This column does not contribute to the stability of the frame
31
Sway frame for a small covered road bridge Haunched frame in longitudinal direction Minimal bracing, combined with roof diaphragm in lateral direction
32
Combined stresses Bi-axial bending Bending and compression
33
Heavy timber trusses Abbotsford arena
34
Roundhouse Lodge, Whistler Mountain
35
neutral axis f max = f a + f bx + f by < f des ( P f / A ) + ( M fx / S x ) + ( M fy / S y ) < f des (P f / A f des ) + (M fx / S x f des ) + (M fy / S y f des ) < 1.0 (P f / P r ) + (M fx / M r ) + ( M fy / M r ) < 1.0 x x f bx = M fx / S x M fx y y f by = M fy / S y M fy The only fly in the pie is that f des is not the same for the three cases f a = P f / A PfPf
36
Moment amplification ΔoΔo Δ max P P P E = Euler load
37
Interaction equation Axial load Bending about y-axis Bending about x-axis
38
3 storey walk-up (woodframe construction)
39
New Forestry Building, UBC, Vancouver
40
Stud wall construction
41
sill plate d L studs top plate wall plate joists check compression perp. wall and top plate help to distribute loads into studs