Download presentation
Presentation is loading. Please wait.
Published byJamal Broome Modified over 9 years ago
1
1 Sensor and Actuator Slides Seth Young Mecatronics March 2006
2
2 Sensor: MS5534A Digital Barometer Seth Young Mecatronics March 2006
3
USU 3/16 Highlights Integrated pressure sensor Pressure range 300-1100 mbar 15 Bit ADC 6 coefficients for a software
4
USU 4/16 Highlights (cont.) compensation stored on-chip 3-wire serial interface 1 system clock line (32.768 kHz) Low voltage / low power
5
USU 5/16 Applications Mobile altimeter/barometer system Weather control systems Adventure or multi-mode watches GPS Receivers
6
USU 6/16 Block Diagram
7
USU 7/16 Operation Overview Altitude measurement based on barometric pressure is a function of temperature The MS5534A Digital Barometer senses both pressure and temperature Both pressure and temperature outputs are converted from analog to digital on-chip
8
USU 8/16 Operation Overview (cont.) Outputs: Pressure: 16 bit number “D1” Temperature: 16 bit number “D2” Each sensor is factory calibrated at two pressures and temperatures. This gives two constants. Pressure, Temperature, and the constants are used off-chip to calculate the altitude
9
USU 9/16 Pin Configuration
10
USU 10/16 Maximum Ratings Supply voltage—min: -0.3 V, max: 4 V Overpressure—max: 10 bar Storage Temperature—min: -20, max: +70 C
11
USU 11/16 Recommended Operating Conditions
12
USU 12/16 Typical Performance Curves
13
USU 13/16 Typical Performance Curves (cont.)
14
USU 14/16 Typical Performance Curves (cont.)
15
USU 15/16 Altitude readout steps 1. Word 1 to Word 4 are read out of the serial interface. 2. Compensation coefficients C1 to C6 are extracted through the serial interface. 3. Then the 16 bit pressure and 16 bit temperature numbers can be read out in a loop. 4. Altitude is calculated from pressure, temperature, and the constants off-chip.
16
USU 16/16 Operation Flow Diagram
17
USU 17/16 Operation Flow Diagram (cont.)
18
USU 18/16 Operation Flow Diagram (cont.)
19
USU 19/16 Arrangement of calibration data in word1 to word4
20
USU 20/16 Method for compensating for non- linearity
21
USU 21/16 Serial interface The altimeter communicates with the rest of the system via a 3 wire serial interface SCLK (serial clock) initiates that data transfer Bits are sampled and sent on the rising edge of SCLK Transactions are initiated by a code sent to the altimeter on the DIN line Responses are sent back on the DOUT line
22
USU 22/16 Accusition sequence for D1 & D2
23
USU 23/16 Acquisition sequence for word 1 & 2
24
USU 24/16 Reset sequence
25
USU 25/16 Application example: an altimeter
26
USU 26/16 Package size
27
USU 27/16 PCB board mounting
28
28 Actuator: SQL Series Linear Motors Seth Young Mecatronics March 2006
29
USU 29/16 Features: Piezoelectric motor Scalable to millimeters in size Simple construction for high-volume, low-cost manufacturing Direct linear movement
30
USU 30/16 Features (cont.): Robust construction to withstand high shock loads Sub-micrometer precision Silent, ultrasonic operation Wide operating temperature range
31
USU 31/16 Overview SQL series linear SQUIGGLE motors are very small and have low power requirements. Because of this they are great for medical devices that are portable. They can withstand high shock. They also offer sub- micrometer precision and can supply up to four Newtons of force.
32
USU 32/16 Overview (cont.)
33
USU 33/16 Advantages of the Squiggle motor Electromagnetic motors have reached the limit of minimization In EM motors, more power is converted to heat than motion in motors smaller than 6mm There is less torque to overcome friction in the micro-gears
34
USU 34/16 Advantages of the Squiggle motor Squiggle motor gives greater efficiency for power Higher reliability Ten times better precision than EM motors
35
USU 35/16 Ultrasonic driver
36
USU 36/16 Design Fundamentally threaded nut and screw Two-phase sinusoidal drive signals cause piezoelectric actuators to vibrate the nut at fixed resonate frequency Because it’s ultrasonic it’s very quiet
37
USU 37/16 Design (cont.) The nut vibrates in a “hula hoop” motion The screw translation is bidirectional and the position of the tip of the screw is precisely controlled by the driver A position sensor is required to achieve repeatable steps.
38
USU 38/16 Design (cont.) The vibration stops at zero power and the threads hold position with very high stability and stiffness. Battery power is preserved because the screws stay in position without continuous power.
39
USU 39/16 Squiggle motor
40
USU 40/16 Squiggle 3.4 mm x 10 mm standard evaluation model
41
USU 41/16 Squiggle 3.4 mm x 10 mm
42
USU 42/16 Squiggle 3.4 mm x 10 mm
43
USU 43/16 Squiggle 3.4 mm x 10 mm
44
USU 44/16 SQUIGGLE 2.4 mm x 10 mm Standard evaluation model
45
USU 45/16 SQUIGGLE 2.4 mm x 10 mm
46
USU 46/16 SQUIGGLE 2.4 mm x 10 mm
47
USU 47/16 SQUIGGLE 2.4 mm x 10 mm
48
USU 48/16 MC-1000 Resonant Drive Board and HS-1000 Handset Drive board demonstrates a circuit that can be put onto an ASIC Operates a single SQL motor and can be controlled by a handset Uses a Microchip dsPIC30F3010 microprocessor at 20 MIPS
49
USU 49/16 MC-1000 Resonant Drive Board and HS-1000 Handset
50
USU 50/16 MC-1000 Resonant Drive Board and HS-1000 Handset
Similar presentations
© 2024 SlidePlayer.com. Inc.