1 Productivity Comparison CR vs. DR

2 The Economic Reason for CR & DR

3 CR Defined CR Equipment

4 DR Defined DR Equipment

5 Introduction Workflow: CR- based Workflow: DR- based

6 Assumptions The comparison will look at radiographic imaging, not the production of cross- sectional imaging on film, nor imaging for interventional radiology

7 Assumptions CR and DR operation An RIS and PACS are in place The systems support DICOM MWL and PPS Reading is done on PACS diagnostic workstations

8 Fundamental Steps in the Process End the examination Move the patient out of the examination room Move images to the radiologist to be read

9 CR-based Workflow (Steps 1-2) From the reception desk or inpatient schedule, determine the next patient to be examined Call for the patient from the waiting room or floor

10 CR-based Workflow (Steps 3-4) While the patient is changing or being put into the room, call up the worklist on the CR workstation Select the appropriate patient and exam from the worklist

11 CR-based Workflow (Steps 5-8) ID the plate Position the patient and the CR plate Set the generator and make the exposure If there is more than one view, repeat the above three steps until done

12 CR-based Workflow (Steps 9-11) Carry the CR plates to the plate reader Stack the plates in the reader input View the images on the CR reader workstation to be sure of correct position and exposure

13 CR-based Workflow (Steps 12-14) If the images are not acceptable, return to re-take the necessary views If the images are acceptable, check the patient ID and request number If correct, send the study to PACS

14 CR-based Workflow (Steps 15-16) If not correct, edit as needed, then send the study to PACS Return to the exam room and have the patient dress or move to the holding area

15 CR-based Workflow 16 steps No film library steps The major change is eliminating separate interaction with the RIS

16 CR-based Workflow: Variations Some systems have the technologist select the patient and exam at the plate reader Others use the ID and information recorded on the cassette to associate the images with the patient and exam This changes where a step is done; it does not add a step

17 CR Alternatives Dedicated chest and rapid-type rooms Many CR Vendors are setting up relationships with DR vendors to meet this need

18 DR-based Workflow (Steps 1-3) From the reception desk or inpatient schedule, determine the next patient to be examined Call for the patient from the waiting room or floor Have the patient change or moved into the exam room; log into the DR system

19 DR-based Workflow (Steps 4-7) Select the patient and examination from the worklist Position the patient Set the generator and make the exposure If more than one view is needed, repeat the above two steps

20 DR-based Workflow (Steps 8-11) On the DR system or a QC workstation, view the images taken If not acceptable (photon starvation/positioning), repeat the needed views If acceptable, end the examination on the DR system Discharge patient

21 DR-based Workflow Reduced to 10 to 11 steps No file room tasks No interaction with cassettes

22 DR-based Workflow A single system for capture, QC, and sending to PACS Uses DICOM MWL and PPS to eliminate technologist interactions with the RIS Eliminates carrying cassettes or plates Eliminates a separate ID step

23 Additional Pros for DR Technology Direct capture means: No phosphors No scintillators No intermediate steps No light to diffuse or scatter Nothing to degrade the quality of the digital signal

24 Downside of DR Replace existing tables/wall Buckys May have to replace the generator if the system cannot be integrated with it Not having DICOM MWL and PPS obviates many of the advantages Portable?

25 Schematic of Workflows Find study to do Get paperwork Get patient Begin exam RIS Position patient Expose Add views? Flash ID Carry cassettes Process films Reload film Pick up films QC films Films OK? Films to FL Log into RIS Complete exam Log exam Discharge Pt Log exam in RIS Locate master Make exam folder Put in TBR slot Load alternator Log loc in RIS Find study to do Get patient Expose Position patient Call up WL Pick from WL ID Plate Add views? Carry plates Run plates View images Images OK? ID OK?Edit info Images to PACS Discharge Pt Find study to do Get patient Pick from WL Add views? Position patient View images Login to DR Expose Images OK? End DR exam Discharge Pt Film-basedCR-based DR-based

26 Other Workflow Considerations Poor planning can defeat the advantages of CR and DR If you design a department for technologist and patient movement as though you were using film, you may create problems

27 Planning Considerations For CR, a rate-limiting step may be how far the plate readers are from the examination rooms Technologist walking time may become significant

28 Planning Considerations For DR, poor layout may make moving patients into and out of the rooms a rate- limiting step Don’t just consider space when designing for film replacement; plan around “traffic flow” as well26

29 Additional Workflow These workflow examples stop at the step at which the radiologist would interpret the exam There are additional workflow improvements for PACS over film, but there is less of an impact from particular imaging methods

30 CR vs. DR An objective assessment and comparison of computed radiography (CR) versus digital radiography (DR) and screen-film for performing upright chest examinations on outpatients is presented in terms of: Workflow Productivity Speed of service Potential cost justification

31 How Was The Study Conducted Perceived ease of use and workflow of each device was collected via a technologist opinion survey. Productivity is measured as the rate of patient throughput from normalized timing studies. The overall speed of service is calculated from the time of examination ordering as stamped in the RIS, to the time of image availability on the PACS, to the time of interpretation rendered (from the Transcription System). A cost comparison is discussed in terms of potential productivity gains and device expenditures. Comparative results of a screen-film (analog) dedicated chest unit versus a CR reader and a DR dedicated chest unit show a higher patient throughput for the digital systems.

32 The Statistics A mean of 8.2 patients were moved through the analog chest room per hour, versus 9.2 patients per hour using the CR system and 10.7 patients per hour with the DR system. This represents a 12% increase in patient throughput for CR over screen-film; a 30% increase in patient throughput for DR over screen-film, which is statistically significant; and a 16% increase in patient throughput for DR over CR, which is not statistically significant.

33 Measurements Measured time to image availability for interpretation is much faster for both CR and DR versus screen-film: With the mean minutes to image availability calculated as 29.2 ± 14.3 min for screen-film 6.7 ± 1.5 min for CR 5.7 ± 2.5 min for DR This represents an improved time to image availability of: 77% for CR over screen-film 80% for DR over screen-film 15% for DR over CR These results are statistically significant (P <.0001) for both CR over screen-film and DR over screen-film but not statistically significant for DR over CR.

34 Conclusion A comparison of the digital technology costs illustrates that the high cost of DR may not be justifiable unless a facility has a steady high patient volume to run the device at or near 100% productivity. Both CR and DR can improve workflow and productivity over analog screen-film in a PACS for delivery of projection radiography services in an outpatient environment. Cost justification for DR over CR appears to be tied predominantly to high-patient volume and continuous rather than sporadic use patterns.

35 Additional Notes There is a potential for workflow improvement in moving from film to CR and from CR to DR These improvements require integration with HIS, RIS as well as the Transcription/Dictations Systems Don’t forget department layout effects on workflow (location, location, location)


Download ppt "Productivity Comparison CR vs. DR. The Economic Reason for CR & DR."